UPP-Gauss: Ultrasound Propagation Physics-informed Gaussian Splatting for B-mode Novel-View Synthesis

Guil Jung, Seok-Hwan Oh, Myeong-Gee Kim, Young-Min Kim, Hyeon-Jik Lee, Sang-Yun Kim, Hyeok-Jun Kwon, Hyuk-Sool Kwon, Hyeon-Min BaearXiv 2026

TL;DR

Standard 3D reconstruction methods treat the world like a photograph—light bounces off surfaces and hits a camera. Ultrasound doesn't play by optical rules; it relies on sound waves plunging into tissue, casting shadows behind bones, and changing texture depending on the probe's angle. UPP-Gauss rewires 3D Gaussian Splatting with actual acoustic physics, allowing us to synthesize crisp, unseen 2D ultrasound cross-sections in real time (over 650 frames per second).

What Problem Does This Paper Address?

When a clinician performs a standard 2D "B-mode" (brightness-mode) ultrasound, it’s a bit like looking into a dark room through a narrow slit—they have to mentally stitch together 2D slices to imagine 3D anatomy. "Novel-view synthesis" aims to take a sweep of tracked 2D ultrasound frames, build a consistent 3D representation, and generate new views from arbitrary probe angles.

Recently, Neural Radiance Fields (NeRFs) and 3D Gaussian Splatting (3DGS) revolutionized this for regular cameras. However, applying optical models to ultrasound falls short. Ultrasound images are formed along parallel sound beams ("A-lines") sent down into the body. Microscopic tissue structures scatter sound to create speckled textures, sharp boundaries between organs reflect sound brightly while casting dark "acoustic shadows" underneath, and energy steadily attenuates with depth. Earlier neural methods (like Ultra-NeRF) modeled some of this physics, but required heavy neural network queries that made them sluggish. Recent Gaussian approaches sped things up, yet treated scattering, reflection, and attenuation as simple, disconnected math terms rather than an interconnected physical journey.

Methods

Enter UPP-Gauss (Ultrasound Propagation Physics-informed Gaussian Splatting). Instead of using one cloud of 3D Gaussians (fuzzy 3D ellipsoids) to represent color and opacity, the authors deploy three independent 3D Gaussian fields—one each for Scattering ($S$), Reflection ($R$), and Attenuation ($A$).

Fig. 1. Overview of UPP-Gauss. The scattering, reflection, and attenuation Gaussian fields are sampled on the probe imaging plane and combined through local echo formation and depth-wise transmission to synthesize a B-mode image.

Here is how UPP-Gauss synthesizes a frame from a given probe pose:

  1. Plane-Slicing Instead of Pinhole Splatting: Rather than projecting 3D blobs onto a 2D camera lens, UPP-Gauss slices directly through the 3D Gaussian clouds along the flat 2D plane defined by the ultrasound probe, sampling nearby Gaussians (within a 5 mm radius) to build three distinct 2D acoustic maps ($M_S, M_R, M_A$).
  2. Beam-Direction-Dependent Scattering: In standard 3DGS, Spherical Harmonics (SH) make objects shimmer differently depending on camera viewing angles. UPP-Gauss repurposes SH (up to degree 2) for the scattering field, evaluating them along the probe’s parallel acoustic beam direction so tissue speckle naturally shifts as the probe tilts.
  3. Physics-Informed Composition: Marching downward from the probe face along each A-line, the final pixel brightness is calculated as Local Echo $\times$ Depth-Wise Transmission. Local echo sums scattering ($M_S$) and bounded reflection ($\overline{M}_R$). Crucially, each reflection Gaussian also learns a "shadow-coupling weight"—meaning a strong reflector both lights up locally and chokes off the transmitted sound energy ($T$) reaching deeper tissues, working alongside cumulative attenuation ($M_A$).

Datasets

The authors test UPP-Gauss across three acoustically distinct scenarios:

  • Spine Phantom (Public): Features hard bone-like interfaces that test strong reflections and deep posterior acoustic shadows (40° angular sweep).
  • Ex-vivo Porcine Muscle (Public): Dominated by fine soft-tissue scattering and striated textures (6° angular sweep).
  • In-vivo Thyroid (Newly Acquired): To test messy clinical reality, the authors collected freehand transverse neck sweeps from 13 human participants using an optically tracked linear probe (120 frames per sweep, ~8° angular coverage), capturing heterogeneous live anatomy.

Key Insights and Ideas

  • Reflections pull double duty: In real acoustics, energy reflected back to the probe is energy lost to deeper tissues. By coupling local bright echoes and downstream transmission loss to the same reflection field (modulated by a learnable weight per interface), UPP-Gauss naturally renders realistic acoustic shadows behind bones without ad-hoc tricks.
  • Decoupling lets specialists specialize: Ablation visualizations reveal a clean division of labor. When forced to work alone, the scattering map tries to memorize everything and blurs out. In the full model, the reflection map locks onto sharp organ boundaries and bone surfaces, freeing the scattering map to focus purely on fine tissue speckle.
Fig. 3. Qualitative acoustic-map ablation on porcine muscle.
  • Orientation matters for speckle: Adding directional awareness (Spherical Harmonics) to the scattering field boosted reconstruction quality on the spine phantom by over 2.2 dB PSNR compared to isotropic scattering—proving how much ultrasound appearance depends on the angle at which the beam strikes tissue fibers.

Key Results

UPP-Gauss achieves state-of-the-art reconstruction quality across all three datasets while being the fastest learning-based renderer in the lineup:

  • Image Quality: It improves PSNR over the strongest baseline on each dataset by an average of 1.43 dB—hitting 29.47 dB on Spine Phantom (+2.13 dB over UltraG-Ray), 26.99 dB on Porcine Muscle (+0.64 dB over ImplicitVol), and 24.07 dB on In-vivo Thyroid (+1.51 dB over UltraG-Ray).
  • Blazing Speed & Efficiency: Because it slices explicit Gaussians directly on the 2D plane without ray-marching neural networks, UPP-Gauss renders a $224 \times 224$ frame in 1.49 ms (~671 FPS) using just 0.33 GFLOPs. That is nearly $6\times$ faster than Ultra-NeRF (8.98 ms) and noticeably leaner than prior Gaussian ultrasound methods like UltraGS (2.42 ms) and UltraG-Ray (2.50 ms).
Fig. 2. Qualitative comparison on spine, porcine muscle, and thyroid. Error maps show absolute errors.

Limitations and Future Work

Currently, UPP-Gauss assumes a linear-array transducer, where acoustic A-lines travel as neat, parallel beams perpendicular to the flat probe face. However, clinical ultrasound frequently uses curvilinear (convex) or phased-array probes that fan beams outward like windshield wipers. Extending this plane-sliced, physics-informed Gaussian formulation to diverse, non-parallel probe geometries is the authors' primary target for future work.

Summary updated