Unsupervised Physics Informed Decomposition of Incomplete Time-Resolved Spectroscopy

Tom Muir, Qifeng Liu, Mohammadrahim Kazemzadeh, William Mills, Ales Leonardis, Huabing Yin, Alexander KrullNeurIPS 2026

TL;DR

Raman spectroscopy lets us identify molecules without touching them, but the faint signal is usually drowned out by a glaring fluorescent background that scientists normally have to wait ages to burn away with a laser. This paper introduces LUMOS, an unsupervised, physics-informed AI that extracts crisp Raman spectra from just the first few seconds of that "bleaching" process—no clean training labels required. Better yet, it turns out the annoying background decay that scientists usually throw away actually holds hidden clues about the sample itself.

What Problem Does This Paper Address?

Imagine trying to photograph the stars at noon. That’s essentially the challenge of Raman spectroscopy. When you shine a laser on a biological or chemical sample, a tiny fraction of light scatters back at shifted wavelengths—a unique molecular fingerprint called the Raman spectrum. Unfortunately, samples also fluoresce, glowing brightly and creating a massive, noisy background "baseline" that swamps the delicate Raman peaks.

To fix this in the lab, researchers often rely on photobleaching: blasting the sample with the laser until the glowing fluorophores exhaust themselves and fade away. It works, but waiting for complete bleaching is painfully slow and can fry delicate, living cells. Computational baseline-removal tools exist, too, but traditional algorithms require finicky manual tuning, and supervised deep learning models falter when real-world lab noise doesn't match their synthetic training data. Can we get clean spectra fast, without waiting for full bleaching and without needing clean ground-truth data to train on?

Figure 1: Spectral Raman time series consist of consecutive spectral measurements, in which the true Raman spectrum is obscured by a diminishing fluorescent baseline. Top: LUMOS takes a partially observed spectral time series as input and decomposes it into a set of exponentially decaying fluorophores and a constant Raman spectrum. LUMOS outperforms state-of-the-art methods in the extraction of Raman spectra on real and multiple simulated datasets, while additionally recovering fluorophore decay behaviour, which may itself carry valuable information. Bottom: Superimposed input spectra of the time series, the predicted fluorophores, and the extracted Raman spectrum compared with ground truth and a classical baseline, for an example from the Pharmaceutical Ingredients dataset [8].

Methods

The authors introduce LUMOS (Latent Un-Mixing of partially Observed Spectra), which marries a standard Variational Autoencoder (VAE) with an explicit, analytical physics model of how spectroscopy actually works.

Here is what is standard vs. novel:

  • The Encoder (mostly standard, with a twist): A 2D Convolutional Neural Network compresses a short, noisy time-series of spectra into a latent code. Because peak locations matter in spectroscopy (unlike cats in images, a peak at $1000\text{ cm}^{-1}$ means something specific), the authors feed normalized wavenumber and time coordinates in as extra channels, followed by temporal pooling so the network can digest sequences of any length.
  • The Physics-Informed Decoder (the secret sauce): Instead of a black-box neural network trying to paint a clean spectrum from scratch, LUMOS learns a global dictionary of physical building blocks across the dataset:
  • Raman peaks modeled as Voigt profiles (the true physical shape of molecular vibration peaks).
  • A bank of fluorophore spectra that make up the glowing background.
  • A parametric noise model approximating camera readout and photon shot noise.

For each sample, a lightweight network reads the latent code and predicts the recipe: the intensity of each Raman peak, plus the abundance and exponential decay rate of each fluorophore. Because the physics constrains what a constant Raman signal vs. a decaying fluorescent baseline can look like, LUMOS learns to unmix them completely unsupervised—even if the input recording stops long before the fluorescence has finished fading.

Figure 2: LUMOS is trained as a VAE. A partially observed noisy spectrum is encoded into a latent space posterior, where the KL loss is computed. The decoder takes a latent sample and produces peak intensities for each of the globally learned Raman peaks, as well as decay rates and abundances for each of the globally learned fluorophore spectra. The reconstruction is computed as the sum of decaying fluorophores and the constant Raman spectrum. We use an ℓ1 regularisation loss on the Raman spectrum. Finally, our globally learned noise model is used to compute the reconstruction loss between input and the corresponding part (grey) of the reconstruction.

Datasets

LUMOS is evaluated on five datasets—four synthetic benchmarks built by combining real clean Raman spectra with simulated multi-fluorophore bleaching and camera noise, plus one brand-new real-world dataset:

  • Human Cell Dataset (New!): A publicly released collection of 431 real photobleaching time-series ($0.1\text{ s}$ per frame) across four human cell types: bone, cartilage, stem cells, and MCF-7 breast cancer cells (266 sequences used after quality control). Unlike single-snapshot datasets, this captures real-time bleaching dynamics.
  • Synthetic Benchmarks: Built from existing libraries covering Pharmaceutical Ingredients, Cancer Cell Metabolites (SERS spectra), RRUFF Minerals, and Mutant Wheat.

Key Insights and Ideas

  • Don't wait for the glow to die—watch how it dies: Even when fluorescence is still strong, watching just a brief snippet of its downward trajectory gives a physics-informed model enough leverage to separate constant Raman peaks from decaying backgrounds.
  • One person's trash is another's biomarker: Conventional workflows treat fluorescence as pure nuisance. By plotting UMAP projections of the extracted parameters on human cells, the authors show that fluorophore decay rates cluster cell types (like grouping stem cells together) in ways static snapshots cannot. Because decay rates depend on a molecule's local cellular microenvironment, bleaching kinetics are a free, untapped source of biological information.
  • Amortized learning beats per-sample curve fitting: Fitting the exact same physical equations to one sample at a time via standard optimization flops (Pearson $r = 0.43$). Sharing a VAE across a dataset—even as small as 240 measurements—lets the model learn shared structure and nail the high-frequency details ($r = 0.93$).

Key Results

Using a single hyperparameter configuration across all datasets, LUMOS beats every non-learning and unsupervised baseline on every dataset and spectral quality metric—and frequently beats a fine-tuned supervised state-of-the-art model (RADAR).

  • Real Human Cells (16 frames / $1.6\text{ s}$): LUMOS achieves the highest Pearson correlation ($0.94$ vs. $0.90$ for IarPLS+SG and $0.89$ for supervised RADAR) and best downstream peak detection ($\text{AUPRC} = 0.38$, $\text{Max F1} = 0.53$).
  • Massive Speedup: On the Cancer dataset, LUMOS using just 8 frames ($0.8\text{ s}$) outperforms classical baselines given 64 frames ($6.4\text{ s}$) across all spectral metrics ($r = 0.91$ vs. $0.89$)—an 8$\times$ reduction in acquisition time and laser damage. Remarkably, even with a single frame (zero temporal info), LUMOS's physical priors still beat 64-frame SavGol+iModPoly in PSNR ($16.6$ vs. $13.4\text{ dB}$).
Figure 3: Qualitative comparison of extracted Raman spectra across all four synthetic datasets and the real cell dataset. Top row: input frames of the bleaching time series. Bottom row: extracted Raman spectra for each method. All methods operate on the first T=16 frames; single-frame baselines receive these as a single long exposure sum. Each column corresponds to a representative test sample from one dataset.

Limitations and Future Work

  • Extreme low-light conditions: Performance dips when extreme photon shot noise dominates, likely because the Gaussian noise approximation misses the skewness of true Poisson noise.
  • Peak position precision: Simplified Voigt peak assumptions mean LUMOS occasionally trails baselines slightly in exact sub-wavenumber peak positional error (e.g., $1.38\text{ cm}^{-1}$ vs. $1.04\text{ cm}^{-1}$ on Cancer).
  • Imperfect real-world ground truth & calibration: Real cell "ground truth" had to be approximated by smoothing and baseline-correcting late frames (which may actually slightly favor classical baselines in evaluation). Additionally, the VAE's posterior uncertainty estimates are currently overconfident, pointing toward unsupervised uncertainty calibration and richer noise/bleaching models as exciting next steps.

Summary updated

Abstract

Raman spectroscopy is often hindered by strong autofluorescence backgrounds and noise. While methods for computational removal exist, better results are often achieved through a time-intensive process of waiting for fluorescence to bleach before recording the Raman spectrum. Here, we instead show that short, incomplete recordings of the bleaching process already contain enough information to recover the underlying Raman signal. We present the first unsupervised model that operates on short, incomplete, variable-length sequences of time-resolved measurements, decomposing them into Raman spectra and autofluorescence components while simultaneously removing measurement noise. Our VAE-based method simultaneously learns (i) a bank of fluorophore spectra comprising the baseline, (ii) possible peak positions and shapes, (iii) a model of the measurement noise, and (iv) neural networks for the decomposition of Raman spectra and decay behaviour. We evaluate our method on spectral reconstruction and downstream peak detection, where it outperforms state-of-the-art approaches on multiple simulated benchmarks as well as on a newly collected real-world dataset of spectral time series. We further show that normally disregarded fluorescence decay dynamics themselves may contain discriminative information that can be exploited in future work.
BibTeX
@inproceedings{muir2026unsupervised,
  author = {Tom Muir and Qifeng Liu and Mohammadrahim Kazemzadeh and William Mills and Ales Leonardis and Huabing Yin and Alexander Krull},
  title = {{Unsupervised Physics Informed Decomposition of Incomplete Time-Resolved Spectroscopy}},
  booktitle = {Advances in Neural Information Processing Systems},
  year = {2026},
  url = {https://openreview.net/forum?id=C4YjfEPhRx},
}

Loading related content...

Figure