Uniformity of spheroid-on-chip by surface treatment of PDMS microfluidic platforms

Neda Azizipour, Rahi Avazpour, Mohamad Sawan, Derek H. Rosenzweig, Abdellah AjjibioRxiv 2022 · DOI

TL;DR

This paper tackles the challenge of creating uniform, healthy spheroids on microfluidic chips for better drug screening. By modifying the surface properties of PDMS (a common material for these chips) with anti-fouling coatings like BSA and Pluronic F-68, the researchers found they could effectively prevent unwanted cell adhesion and promote self-aggregation into well-formed spheroids. This work provides a crucial step towards more reliable and physiologically relevant 3D cell culture models for cancer research.

What Problem Does This Paper Address?

Spheroids, which are 3D cell cultures that mimic tumors more closely than traditional 2D cultures, are increasingly used for drug screening and understanding cancer. Microfluidic platforms offer precise control over the cellular environment, making them ideal for spheroid-based studies. However, a major hurdle in using these platforms is controlling the size and uniformity of the spheroids. This is largely due to the challenge of managing cell adhesion to the microfluidic chip's surface. Uncontrolled adhesion can lead to non-uniform spheroid formation, clogs, and unreliable experimental results. This paper aims to address this by systematically investigating how surface modifications of PDMS, a popular material for microfluidic devices, can be used to control cell adhesion and thus improve spheroid formation.

Methods

The researchers employed a multi-pronged approach to modify and characterize the PDMS surface:

  • PDMS Fabrication: Standard PDMS layers were fabricated using Sylgard 184 silicone elastomer kit.
  • Surface Modification:
    • Oxygen Plasma Treatment: PDMS layers were treated with oxygen plasma to temporarily increase surface hydrophilicity.
  • Chemical Coating: Two common anti-fouling agents, Bovine Serum Albumin (BSA) and Pluronic F-68 (a triblock copolymer), were applied at different concentrations (3%, 5%, 10%) and incubation times (less than 1 hour, overnight) to create cell-repellent surfaces.
  • Surface Characterization:
    • Water Contact Angle (WCA): Measured to quantify the surface wettability (hydrophilicity/hydrophobicity).
  • Scanning Electron Microscopy (SEM): Used to visualize the surface topography at a micro-scale.
  • Atomic Force Microscopy (AFM): Employed to obtain nano-scale insights into surface morphology and roughness.
  • ImageJ Analysis: Used to quantify surface coverage based on color intensity in AFM images.
  • Spheroid Formation and Analysis:
    • Microfluidic Device Design: A modified microfluidic device with specific channel and well dimensions was used.
  • Cell Culture: Human breast cancer cell line (MDA-MB-231-GFP) was cultured.
  • Spheroid Imaging: Epifluorescence microscopy was used to capture spheroid growth over 7 days.
  • Data Analysis: ImageJ was used to analyze spheroid size (diameter), circularity, and brightness level ratio (indicating uniformity and cell density).

Datasets

Not discussed in the paper. The study uses a human breast cancer cell line (MDA-MB-231-GFP) for spheroid formation.

Key Insights and Ideas

  • Surface Properties are Key: The study strongly emphasizes that the surface properties of PDMS (wettability, morphology, roughness) are critical determinants of cell adhesion and subsequent spheroid formation.
  • Anti-fouling Coatings Work: Both BSA and Pluronic F-68 effectively reduced cell adhesion to PDMS, promoting self-aggregation into spheroids.
  • Concentration and Incubation Time Matter: The effectiveness of the anti-fouling coatings is highly dependent on both the concentration of the coating agent and the duration of incubation. There isn't a one-size-fits-all approach.
  • Moderate Hydrophilicity is Optimal: The research suggests that moderately hydrophilic surfaces (62-88 degree water contact angle) exhibit the highest cell-repellent properties, leading to better spheroid formation.
  • BSA vs. Pluronic F-68 Nuances: While both coatings were effective, BSA showed better results at higher concentrations (5-10%), whereas Pluronic F-68 was effective even at lower concentrations (3%), with 5% being identified as potentially optimal for uniform spheroid formation.
  • Surface Roughness Changes: Surface modification with BSA and Pluronic F-68 generally increased surface roughness, which was linked to improved cell repulsion.

Key Results

  • Reduced Cell Adhesion: Treated PDMS surfaces showed significantly less cell attachment compared to untreated surfaces.
  • Improved Spheroid Formation: Surface treatments facilitated the formation of more uniform and healthier spheroids.
  • Optimal Conditions Identified:
    • BSA: 10% concentration showed the best cell repellent properties and highest number of spheroids formed.
  • Pluronic F-68: 3% concentration was effective, with 5% potentially being optimal for uniform spheroid formation due to sufficient surface coverage.
  • Spheroid Viability: Spheroids maintained high viability (above 70%) for 7 days, with some remaining viable for up to 14 days.
  • Surface Roughness: Increasing coating concentration generally decreased surface roughness and increased surface coverage.

Limitations and Future Work

  • Complexity of Cell Adhesion: The authors acknowledge that the relationship between surface properties and cell adhesion is complex and not fully understood.
  • Exclusion of Other Parameters: The study focused on chemical properties of treated surfaces, excluding other parameters like surface stiffness.
  • Future Work: The authors suggest that this technology is versatile and can be applied to other cell types for more physiologically relevant studies. They also highlight the need for further understanding of the intricate relationship between surface properties and cell adhesion. The development of a simple, effective, and repeatable method to modify PDMS surfaces for spheroid formation without expensive additional materials is a key outcome and a direction for future applications.

Summary updated

Abstract

Abstract Spheroids have emerged as a more reliable model for drug screening when compared with 2D culture models. Microfluidic based biochips have many advantages over other 3D cell culture models for drug testing on spheroids, including precise control of the cellular microenvironment. The control of the cell adhesion to the surface is one of the most important challenges affecting the size and the geometry of the spheroids which could be controlled by appropriate surface engineering methods. We have studied the modification of the PDMS surface properties treated by applying different concentrations of the two anti-fouling coatings (BSA and Pluronic F-68). The desired treatment of PDMS surface effectively inhibits cell adhesion to the surface and promotes cells self-aggregations to form more uniform and healthy spheroids for a longer period of time. The microscopic observations with qualitative and quantitate data revealed that surface properties drastically affect the number of the spheroids formed on-chip and their geometry. We used human breast cancer cell line (MDA-MB-231-GFP) while the concentration of the chemical coatings and incubation time were adjusted. Proper repellent PDMS surfaces were provided with minimum cell attachment and facilitated spheroid formation when compared with non-treated PDMS. The results demonstrate fundamental and helpful patterns for microfluidic based cell culture applications to improve the quantity and quality of spheroid formation on-chip which are strongly manipulated by surface properties (i.e., morphology, roughness, wettability and etc.)
BibTeX
@misc{azizipour2022uniformity,
  author = {Neda Azizipour and Rahi Avazpour and Mohamad Sawan and Derek H. Rosenzweig and Abdellah Ajji},
  title = {{Uniformity of spheroid-on-chip by surface treatment of PDMS microfluidic platforms}},
  year = {2022},
  doi = {10.1101/2022.02.15.480543},
  howpublished = {bioRxiv},
}

Loading related content...

Figure