Unicondylar knee arthroplasty using cobalt-chromium implants in patients with self-reported cutaneous metal hypersensitivity
Lists
Only you see this
Abstract
This study is the first demonstrating clinical results and survival analysis of UKA using a CoCr alloy in patients with a history of metal hypersensitivity. Functional outcome and survivorship are on a high-level equivalent to those reported for UKA in patients without a history of metal hypersensitivity. No serious local or systemic symptoms of metal hypersensitivity could be detected, and no revision surgery was performed due to an adverse reaction to metal ions.
BibTeX
@article{walker2019unicondylar,
author = {Tilman Walker and Leszek Rutkowski and Moritz M. Innmann and Benjamin Panzram and Joachim Herre and Tobias Gotterbarm and Peter R. Aldinger and Christian Merle},
title = {{Unicondylar knee arthroplasty using cobalt-chromium implants in patients with self-reported cutaneous metal hypersensitivity}},
journal = {The Bone \& Joint Journal},
year = {2019},
doi = {10.1302/0301-620x.101b2.bjj-2018-0778.r1},
}Loading related content...