Uncertainty Evaluation to Support Safety of the Intended Functionality Analysis for Determining the Applicability of Performance Targets Across Triggering Conditions in ML-Based LiDAR Object Detection

Milin Patel, Rolf JungarXiv 2026

TL;DR

This paper introduces a rigorous statistical "applicability test" to determine if uncertainty thresholds for LiDAR object detectors, calibrated in one environment, still meet safety targets when transferred to new "triggering conditions" like rain or far distances. The authors demonstrate that current industry-standard datasets are often too small to provide the statistical proof required by safety standards like SOTIF (ISO 21448).

What Problem Does This Paper Address?

In the world of autonomous vehicles, perception systems must be reliable. Machine Learning (ML) object detectors often use uncertainty thresholds to filter out "wrong" detections (false positives) before they reach the motion planner. If a detector is unsure about a box, it rejects it.

However, safety standards like SOTIF (Safety of the Intended Functionality) require these systems to work across all possible "triggering conditions"—scenarios like heavy rain or objects at extreme distances that might cause the system to fail. The core challenge is that a threshold tuned to be safe in clear weather might become dangerously optimistic in the rain. Currently, there is no standard way to statistically prove that a safety target met in one condition still holds in another.

Methods

The authors propose a framework based on Learn then Test (LTT) and a novel applicability test:

  1. Uncertainty Indicators: They use a "deep ensemble" (multiple separately trained versions of the same model) to generate two uncertainty scores:
  2. Spatial Indicator ($u_s$): Measures how much the ensemble members disagree on an object's position and size.
  3. Existence Indicator ($u_e$): Measures the average confidence that an object is actually there.
  4. Threshold Selection: Using LTT, they select a threshold on "selection data" that guarantees the False Acceptance Proportion (FAP)—the share of wrong detections among those accepted—stays below a target limit (e.g., 1%).
  5. The Applicability Test: When this threshold is moved to a new condition (the "condition of use"), the test uses confidence intervals to categorize the outcome as:
  6. Applicable: The target is still met.
  7. Not Applicable: The target is exceeded.
  8. Not Determined: There isn't enough data to say for sure.
The applicability test uses confidence intervals to decide if a threshold transferred from condition $c$ to $c'$ still meets the safety limit $\alpha$.

Datasets

The study utilizes two major autonomous driving benchmarks:

  • KITTI: A widely used dataset for 3D object detection.
  • nuScenes: A larger, more diverse dataset that includes specific labels for weather conditions like rain.

The authors specifically test transfers between near and far distances, clear weather and rain, and even between the two datasets themselves to simulate "distribution shift."

Key Insights and Ideas

  • AUROC is not a safety metric: Researchers often use the Area Under the ROC Curve (AUROC) to measure model quality. However, the authors found that in rain, AUROC might stay the same or even improve, while the actual safety limit is being violated. AUROC measures general separation, not whether a specific threshold is safe.
  • The "Independence" Trap: Most ML research treats every video frame as an independent data point. This paper argues that frames within a single recorded sequence are highly dependent. When you treat the sequence as the independent unit (as safety logic requires), the statistical "power" of your dataset drops significantly.
  • Safety vs. Utility: When a threshold successfully transferred and remained "applicable," it often did so by becoming extremely conservative—rejecting nearly all correct detections. This high "withholding" rate means the sensor becomes effectively blind, which is its own safety hazard.
Example of a wrong detection accepted by a transferred threshold that would have been rejected if the threshold were tuned for the specific condition.

Key Results

  • Frequent Failures: Transfers into far distance and rain frequently resulted in "not applicable" outcomes, meaning the safety limit was exceeded.
  • Dataset Size Deficit: To prove a 1% error rate with 95% confidence, you need at least 299 independent units. The authors found that neither KITTI nor nuScenes contained enough independent sequences to prove that any of the tested safety limits ($10^{-2}$ to $10^{-4}$) were met.
  • Distance and Weather Shifts: Figure 4 illustrates that while some thresholds appear "applicable" when counted by frame, many fail or are "not determined" when rigorous statistical bounds are applied.
Outcome of every transfer in the frame-level evaluation. Green indicates applicable, red indicates not applicable.

Limitations and Future Work

  • Scope: The study focused on a single detector architecture (PointPillars) and one object class (cars). Results might differ for pedestrians or different model types.
  • System Context: The paper looks at the detector in isolation. In a real vehicle, temporal tracking and sensor fusion (combining LiDAR with cameras/radar) might mitigate some of these errors.
  • Future Directions: The authors suggest extending the test to more triggering conditions (like occlusion), exploring adaptive thresholds that change in real-time based on weather, and developing "monitors" that can detect distribution shifts without needing human-annotated ground truth.

Summary updated

Abstract

For safety of the intended functionality (SOTIF) analysis according to ISO 21448, a machine learning object detector for light detection and ranging (LiDAR) point clouds can meet a performance target, a limit on the mean per-frame share of wrong detections among accepted detections, by rejecting detections above an uncertainty threshold. A threshold selected on data of one condition carries a statistical guarantee only for data distributed like its selection data, whereas SOTIF analysis covers every triggering condition. This paper presents an uncertainty evaluation in which the threshold is transferred into a triggering condition, a test decides at a stated error probability whether the target is applicable there, not applicable or not determined, and a lower bound counts the independent units an applicable outcome requires. For PointPillars ensembles on KITTI and nuScenes, counted in recorded sequences, as the dependence between frames requires, neither dataset held enough independent units for any target limit, and no transfer had a not applicable outcome. Counted in frames, the same data gave not applicable outcomes at limits fixed in advance after transfers into far distance, into rain and between two separately trained detectors, thresholds that met the target limit after a transfer rejected most correct detections, and in rain the area under the receiver operating characteristic curve did not decrease. A performance target met under one condition therefore counts as evidence under a triggering condition only after a test there, reported with its share of accepted correct detections and its number of independent recorded sequences.

Empirical ResultsBrowse all benchmarks →

BenchmarkMethodMetricScoreProtocol / Evidence
KITTIPointPillars ensemble (spatial uncertainty indicator u_s)AUROC0.845split: validation-test-part-of-split-0
Source quote
L937: 0.915 →0.845 0.34 →0.76 –
nuScenesPointPillars ensemble (spatial uncertainty indicator u_s)AUROC0.655split: validation-test-part-of-split-0
Source quote
L942: 0.729 →0.655 0.19 →0.51 –
KITTIPointPillars ensemble (spatial uncertainty indicator u_s)AUROC0.915split: validation-test-part-of-split-0
Source quote
L937: 0.915 →0.845 0.34 →0.76 –
nuScenesPointPillars ensemble (spatial uncertainty indicator u_s)AUROC0.729split: validation-test-part-of-split-0
Source quote
L942: 0.729 →0.655 0.19 →0.51 –
nuScenesPointPillars ensemble (existence uncertainty indicator u_e)AUROC0.856split: validation-test-part-of-split-0
Source quote
L947: 0.844 →0.856 0.33 →0.42 different spread over
nuScenesPointPillars ensemble (existence uncertainty indicator u_e)AUROC0.844split: validation-test-part-of-split-0
Source quote
L947: 0.844 →0.856 0.33 →0.42 different spread over
KITTIPointPillars ensemble (spatial uncertainty indicator u_s)AUROC0.905split: validation-test-part-of-split-0
Source quote
L953: 0.749 →0.905 0.35 →0.55 shifted values: median 𝑢s
nuScenesPointPillars ensemble (spatial uncertainty indicator u_s)AUROC0.749split: validation-test-part-of-split-0
Source quote
L953: 0.749 →0.905 0.35 →0.55 shifted values: median 𝑢s
BibTeX
@misc{patel2026uncertainty,
  author = {Milin Patel and Rolf Jung},
  title = {{Uncertainty Evaluation to Support Safety of the Intended Functionality Analysis for Determining the Applicability of Performance Targets Across Triggering Conditions in ML-Based LiDAR Object Detection}},
  year = {2026},
  eprint = {2610.35092},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.35092},
}
Figure