Ultrasensitive rapid cytokine sensors based on asymmetric geometry two-dimensional MoS2 diodes

Thushani De Silva, Mirette Fawzy, Amirhossein Hasani, Hamidreza Ghanbari, Amin Abnavi, Abdelrahman M. Askar, Yue Ling, Mohammad Reza Mohammadzadeh, Fahmid Kabir, Ribwar Ahmadi, Miriam P. Rosin, K. L. Kavanagh, Michael M. AdachiNature Communications 2022 · DOI

TL;DR

Researchers have developed a novel, ultrasensitive biosensor using a two-dimensional molybdenum disulfide (MoS2) diode with an asymmetric geometry. This device can rapidly detect tumor necrosis factor-alpha (TNF-α) at extremely low concentrations (fM range) without the need for labels, paving the way for faster and more accessible point-of-care diagnostics for inflammatory diseases.

What Problem Does This Paper Address?

Early detection of diseases often relies on monitoring the levels of specific biomarkers in bodily fluids. Cytokines, small proteins involved in regulating the immune system, are particularly important as their abnormal levels are linked to a wide range of health conditions, including Alzheimer's, cancer, and inflammatory responses like those seen in COVID-19. Current methods for detecting these cytokine biomarkers, such as ELISA, are often time-consuming, expensive, and require significant sample volumes and specialized equipment, limiting their use in rapid, point-of-care settings. While field-effect transistor (FET) biosensors offer label-free detection and high sensitivity, they can suffer from issues like liquid-gating complexities, hysteresis, and high operating voltages. This paper aims to address these limitations by developing a simpler, more robust, and highly sensitive biosensor for cytokine detection.

Methods

The core of this biosensor is a two-dimensional molybdenum disulfide (MoS2) crystal flake with an asymmetric geometry. This asymmetry is achieved by fabricating metal contacts (Cr/Au) of different cross-sectional lengths and areas across the MoS2 flake. This geometric asymmetry inherently creates a diode rectification behavior in the MoS2 crystal.

The MoS2 flake is then coated with a thin insulating layer of aluminum oxide (Al2O3). This layer serves two crucial roles: it facilitates the functionalization of the sensor surface and electrically isolates the metal contacts from the sample solution.

For biosensing, the Al2O3 surface is functionalized with aptamers – short, single-stranded DNA or RNA molecules that can bind specifically to target molecules. In this case, TNF-α-specific aptamers (VR11) are immobilized onto the sensor surface using a silane chemistry approach involving (glycidoxypropyl)trimethoxysilane (GOPS) and 1-1'carbonyldiimidazole (CDI) linkers.

When a sample containing TNF-α is introduced, the TNF-α molecules bind to the aptamers. This binding event causes the aptamer to fold into a G-quadruplex structure, bringing the negatively charged TNF-α closer to the sensor surface. This change in surface charge density alters the electrical rectification behavior of the asymmetric MoS2 diode. The change in the current-voltage (I-V) characteristics of the diode is then measured using a simple two-electrode configuration, providing a quantitative readout of the TNF-α concentration.

Datasets

Not discussed in the paper. The study uses prepared samples of TNF-α at various concentrations for testing.

Key Insights and Ideas

  • Asymmetric Geometry for Diode Behavior: The key innovation is leveraging the inherent asymmetry of the metal-MoS2 contacts to create a diode without requiring doping or complex fabrication steps. This simplifies the device architecture significantly.
  • Label-Free and Rapid Detection: The sensor detects TNF-α directly through changes in electrical properties, eliminating the need for fluorescent labels or enzymatic reactions, which speeds up the detection process.
  • Ultrasensitivity at Femtomolar Levels: The sensor achieves an impressive limit of detection (LOD) of 10 femtomolar (fM), which is well below typical physiological concentrations in healthy individuals and crucial for early disease diagnosis.
  • Simple Two-Electrode Readout: Unlike FETs that require a third gate electrode, this diode sensor uses a straightforward two-electrode setup, simplifying both fabrication and readout electronics.
  • Aptamer Specificity: The use of highly specific aptamers ensures that the sensor primarily detects the target cytokine, minimizing false positives from other molecules.
  • Potential for Point-of-Care: The combination of simplicity, speed, sensitivity, and electrical readout makes this sensor highly suitable for development into a portable, easy-to-use diagnostic tool for clinical settings.

Key Results

  • Limit of Detection (LOD): The sensor achieved an ultrasensitive LOD of 10 fM for TNF-α.
  • Dynamic Range: The sensor demonstrated a wide dynamic detection range of five orders of magnitude, from 10 fM to 1 nM.
  • Rectification Factor (RF) Change: The interaction of TNF-α with the aptamer-functionalized sensor surface induced a measurable change in the diode's rectification factor (RF). This change in RF was directly correlated with the concentration of TNF-α.
  • Specificity: The sensor showed high specificity for TNF-α, with significantly lower responses to non-target proteins like IL-6 and C-reactive protein. The response to C-reactive protein was at most three times lower than that of TNF-α at the same concentration.
  • Control Experiments: A control device without aptamers showed negligible response to TNF-α, confirming that the observed signal was due to specific aptamer-cytokine binding.
  • Rapid Measurement: The detection process, including interaction time, took approximately 2 minutes.

Limitations and Future Work

  • Device-to-Device Variation: Due to the mechanical exfoliation method used to obtain MoS2 flakes, there were variations in flake geometry and thickness, leading to device-to-device differences. The use of a normalized rectification factor (RFN) helped to compare results across devices.
  • Reproducibility: While the normalized RF showed a consistent trend across multiple devices, the authors acknowledge that for commercial applications, lithographic control over flake geometry would be needed for greater reproducibility and scalability.
  • Potential for Non-Specific Binding: While the sensor showed good specificity, some non-specific binding was observed, particularly with C-reactive protein. The authors suggest surface passivation techniques (e.g., using ethanolamine) as a potential solution.
  • Future Work:
    • Scalable Fabrication: Developing large-area compatible processes for preparing MoS2 thin films and patterning them into specific geometries for reproducible and scalable sensor fabrication.
  • Flexible and Wearable Sensors: Leveraging the flexibility and mechanical stability of 2D MoS2 to create flexible and wearable biosensors for continuous health monitoring.
  • Multiplexed Detection: Extending the platform to detect other cytokines or biomarkers by replacing the aptamer receptor with one specific to a different target.

Summary updated

Abstract

Abstract The elevation of cytokine levels in body fluids has been associated with numerous health conditions. The detection of these cytokine biomarkers at low concentrations may help clinicians diagnose diseases at an early stage. Here, we report an asymmetric geometry MoS 2 diode-based biosensor for rapid, label-free, highly sensitive, and specific detection of tumor necrosis factor-α (TNF-α), a proinflammatory cytokine. This sensor is functionalized with TNF-α binding aptamers to detect TNF-α at concentrations as low as 10 fM, well below the typical concentrations found in healthy blood. Interactions between aptamers and TNF-α at the sensor surface induce a change in surface energy that alters the current-voltage rectification behavior of the MoS 2 diode, which can be read out using a two-electrode configuration. The key advantages of this diode sensor are the simple fabrication process and electrical readout, and therefore, the potential to be applied in a rapid and easy-to-use, point-of-care, diagnostic tool.
BibTeX
@inproceedings{silva2022ultrasensitive,
  author = {Thushani De Silva and Mirette Fawzy and Amirhossein Hasani and Hamidreza Ghanbari and Amin Abnavi and Abdelrahman M. Askar and Yue Ling and Mohammad Reza Mohammadzadeh and Fahmid Kabir and Ribwar Ahmadi and Miriam P. Rosin and K. L. Kavanagh and Michael M. Adachi},
  title = {{Ultrasensitive rapid cytokine sensors based on asymmetric geometry two-dimensional MoS2 diodes}},
  booktitle = {Nature Communications},
  year = {2022},
  doi = {10.1038/s41467-022-35278-2},
}

Loading related content...

Figure