Ultrafast and hypersensitive phase imaging of propagating internodal current flows in myelinated axons and electromagnetic pulses in dielectrics

Yide Zhang, Binglin Shen, Tong Wu, Jerry Zhao, Joseph C. Jing, Peng Wang, Kanomi Sasaki-Capela, William G. Dunphy, David C. Garrett, Konstantin Maslov, Weiwei Wang, Lihong V. WangNature Communications 2022 · DOI

TL;DR

This paper introduces Diff-CUP, a novel imaging technique that combines ultra-high speed and extreme phase sensitivity. It allows for the direct visualization of ultrafast phenomena like electrical signal propagation in neurons and electromagnetic pulses in materials, achieving speeds and sensitivities previously unattainable.

What Problem Does This Paper Address?

Understanding how information is processed, both in biological systems like the nervous system and in electronic devices, relies on visualizing rapid dynamic processes. Two key examples are the propagation of electrical signals along nerve fibers (action potentials, APs) and the movement of electromagnetic pulses (EMPs) through materials. While significant progress has been made in imaging APs, visualizing the passive current flows within the myelinated segments of axons, which are crucial for fast conduction, has been challenging due to the speed and sensitivity requirements. Similarly, directly observing EMP propagation with high resolution has been hampered by limitations in existing imaging techniques. The core problem is the need for an imaging method that is simultaneously ultra-fast (picosecond resolution), highly sensitive to minute phase changes, and capable of capturing these events in a non-invasive manner.

Methods

The researchers developed Differentially Enhanced Compressed Ultrafast Photography (Diff-CUP). This technique builds upon their previous Compressed Ultrafast Photography (CUP) platform, which is known for its extremely high frame rates (up to 70 trillion frames per second) and large sequence depth. The key innovation in Diff-CUP is the integration of a Mach-Zehnder interferometer with a differential imaging approach.

Here's a breakdown of the key methodological aspects:

  • Mach-Zehnder Interferometry: This optical setup splits a light beam into two paths (sample and reference). When the light recombines, interference patterns reveal phase shifts caused by changes in the sample. This provides the high phase sensitivity needed to detect subtle events.
  • Differential Imaging: Instead of directly imaging the phase changes, Diff-CUP acquires images with and without the phenomenon of interest (e.g., an EMP or current flow). By subtracting these images, the common background noise and distortions are largely eliminated, leaving only the signal related to the dynamic event. This is described as a form of "software lock-in detection."
  • Compressed Ultrafast Photography (CUP): This core technology provides the ultra-high speed. It uses a technique to encode spatial and temporal information onto a 2D detector, allowing for the reconstruction of a sequence of images from a single snapshot.
  • Two Operating Modes:
    • Uncoded Mode: Prioritizes phase sensitivity with a narrow field of view (FOV). This mode is ideal for imaging one-dimensional phenomena like internodal current flows.
  • Coded Mode: Prioritizes a larger FOV by using a digital micromirror device (DMD) to spatially encode the image. This mode is suitable for observing broader phenomena like EMP propagation.

Datasets

Not discussed in the paper. The experiments utilize biological samples (myelinated axons from Xenopus laevis) and engineered materials (lithium niobate crystals).

Key Insights and Ideas

  • Bridging Extreme Timescales: Diff-CUP successfully visualizes phenomena occurring at vastly different speeds: internodal current flows in neurons (around 100 m/s, taking microseconds to propagate) and electromagnetic pulses in dielectrics (around 5 x 10<sup>7</sup> m/s, propagating in picoseconds). This demonstrates the technique's versatility.
  • Unveiling Hidden Dynamics: The ability to visualize passive internodal current flows directly is a significant breakthrough, as these flows are critical for rapid nerve conduction but have been difficult to observe directly.
  • Unprecedented Sensitivity: The differential approach, combined with temporal correlation and template matching, achieves a phase sensitivity of 20 µrad, which is orders of magnitude better than previous ultrafast imaging techniques. This allows for the detection of extremely weak signals.
  • Non-invasive Imaging: The technique is label-free and operates in transmission mode, making it suitable for observing biological samples without perturbation.

Key Results

  • Myelinated Axon Conduction: Diff-CUP visualized internodal current flows in Xenopus laevis sciatic nerves at an average speed of 100 m/s. This speed is consistent with computational models and electrophysiological measurements of AP conduction in myelinated axons.
  • Electromagnetic Pulse Propagation: The technique imaged EMPs propagating in lithium niobate (LN) at approximately 5 x 10<sup>7</sup> m/s. This speed aligns with known properties of LN and is consistent with simulations.
  • Phase Sensitivity: Diff-CUP achieved a phase sensitivity of 20 µrad, a significant improvement over previous methods. This is a 3400-fold enhancement over non-differential approaches.
  • Frame Rate and Sequence Depth: The system operates at up to 200 billion frames per second with a sequence depth of 350 frames.

Limitations and Future Work

  • Sample Thickness: As a transmission-based technique, Diff-CUP is limited to imaging thin samples, which can restrict the complexity of biological structures that can be studied.
  • Temporal Window: The current time-shearing window of the streak camera limits the observation of dynamic events lasting longer than 1 ms, making it unsuitable for very slow processes like APs in unmyelinated axons or neuronal networks.
  • LN Crystal Bandwidth: The lithium niobate crystal used for EMP induction has a limited bandwidth, restricting the pulse width of injectible EMPs to >100 ps.
  • Phase Value Extraction: Accurately quantifying the absolute phase values of internodal current flows remains challenging due to noise and axon morphology, despite the high sensitivity.
  • Repeatability Requirement: The differential imaging approach requires the dynamic events to be repeatable, limiting its application to non-repeatable phenomena unless modified.

Future work could involve:

  • Replacing the streak camera with longer time-shearing window detectors or high-speed CCD/CMOS cameras to extend the temporal range.
  • Exploring alternative materials or techniques for EMP induction with broader bandwidths.
  • Developing improved algorithms for phase extraction in the presence of noise and complex sample geometries.
  • Adapting the differential approach to other imaging modalities for enhanced sensitivity.
  • Investigating more complex biological systems and ultrafast catalytic processes.

Summary updated

Abstract

Many ultrafast phenomena in biology and physics are fundamental to our scientific understanding but have not yet been visualized owing to the extreme speed and sensitivity requirements in imaging modalities. Two examples are the propagation of passive current flows through myelinated axons and electromagnetic pulses through dielectrics, which are both key to information processing in living organisms and electronic devices. Here, we demonstrate differentially enhanced compressed ultrafast photography (Diff-CUP) to directly visualize propagations of passive current flows at approximately 100 m/s along internodes, i.e., continuous myelinated axons between nodes of Ranvier, from Xenopus laevis sciatic nerves and of electromagnetic pulses at approximately 5 × 10<sup>7</sup> m/s through lithium niobate. The spatiotemporal dynamics of both propagation processes are consistent with the results from computational models, demonstrating that Diff-CUP can span these two extreme timescales while maintaining high phase sensitivity. With its ultrahigh speed (picosecond resolution), high sensitivity, and noninvasiveness, Diff-CUP provides a powerful tool for investigating ultrafast biological and physical phenomena.
BibTeX
@inproceedings{zhang2022ultrafast,
  author = {Yide Zhang and Binglin Shen and Tong Wu and Jerry Zhao and Joseph C. Jing and Peng Wang and Kanomi Sasaki-Capela and William G. Dunphy and David C. Garrett and Konstantin Maslov and Weiwei Wang and Lihong V. Wang},
  title = {{Ultrafast and hypersensitive phase imaging of propagating internodal current flows in myelinated axons and electromagnetic pulses in dielectrics}},
  booktitle = {Nature Communications},
  year = {2022},
  doi = {10.1038/s41467-022-33002-8},
}
Figure