Ultra-High Sensitivity Terahertz Microstructured Fiber Biosensor for Diabetes Mellitus and Coronary Heart Disease Marker Detection

Jia Xue, Yani Zhang, Zhe Guang, Ting Miao, Zohaib Ali, Dun Qiao, Yiming Yao, Kexin Wu, Lei Zhou, Cheng Meng, Nigel Copner2023 · DOI

TL;DR

Researchers have developed a novel terahertz (THz) microstructured fiber (MSF) biosensor capable of ultra-high sensitivity detection of biomarkers for Diabetes Mellitus (DM) and Coronary Heart Disease (CHD). This innovative sensor utilizes a suspended hollow-core design and leverages THz time-domain spectroscopy to offer a rapid, accurate, and non-invasive diagnostic tool.

What Problem Does This Paper Address?

Diabetes Mellitus (DM) and Coronary Heart Disease (CHD) are leading causes of mortality worldwide. Current diagnostic methods for these conditions often involve complex procedures, invasive techniques, or are time-consuming and expensive. There is a critical need for efficient, rapid, and non-invasive diagnostic tools that can accurately detect disease markers. Terahertz (THz) biosensing has emerged as a promising technology due to its unique properties, including low energy, transient absorption, and its ability to interact with biological molecules. However, achieving high sensitivity and low loss in THz biosensors, particularly for complex biomarkers, remains a challenge. This paper aims to address this gap by proposing and simulating an optimized MSF biosensor designed for enhanced detection of DM and CHD markers.

Methods

The core of this research lies in the design and simulation of a novel microstructured fiber (MSF) biosensor. The proposed sensor features a suspended hollow-core structure with a square core and a hexagonal cladding, supported by four arms. This design is intended to maximize the interaction between the THz waves and the analytes within the core while minimizing signal loss.

The simulation of the MSF's optical performance, including modal distribution and transmission characteristics, was conducted using the Finite Element Method (FEM). A perfectly matched layer (PML) was incorporated as an absorption boundary to accurately model wave propagation and minimize reflections. The sensor's performance was evaluated based on key parameters such as relative sensitivity, effective material loss (EML), confinement loss (CL), power fraction, numerical aperture (NA), and effective area.

The researchers employed a control variable method to optimize the MSF's structural parameters, including core side length (l), vertical support arm thickness (d), and horizontal support arm thickness (p). They simulated the sensor's response with different concentrations of DM markers (albumin, glucose, glycated hemoglobin, and triglyceride) and CHD markers (triglyceride), using refractive index and absorption coefficient data from existing literature.

Datasets

The paper does not explicitly mention the use of newly introduced datasets for training or evaluation. Instead, it relies on experimental data from existing literature to obtain the refractive indices and absorption coefficients of the DM and CHD markers. Specifically, data from Reference [2] for diabetic and non-diabetic markers, and Reference [4] for triglyceride levels, were used to model the sensor's performance.

Key Insights and Ideas

  • Suspended Hollow-Core Design: The suspended hollow-core structure is crucial for enhancing the interaction between THz waves and analytes, leading to improved sensitivity. This design also contributes to a significantly reduced confinement loss.
  • Zeonex as Substrate: The choice of Zeonex as the substrate material is highlighted as a key factor for excellent MSF performance due to its low material loss, low water absorption, and stability across the THz band.
  • Optimization is Key: The study emphasizes the importance of optimizing structural parameters (core size, arm thickness) to achieve a balance between high sensitivity, low loss, and efficient light confinement.
  • EML as a Differentiator: The effective material loss (EML) shows significant differences for varying concentrations of disease markers, which is crucial for improving clinical diagnostic accuracy and distinguishing disease severity.
  • Fabrication Feasibility: The proposed MSF design is deemed feasible for fabrication using 3D printing and extrusion technologies, suggesting a pathway for practical implementation.

Key Results

The simulation results demonstrate the effectiveness of the proposed MSF biosensor:

  • Ultra-High Sensitivity: The MSF biosensor exhibits an ultra-high relative sensitivity, reaching up to 100.35% at 2.2 THz when detecting triglyceride markers.
  • Low Confinement Loss: The confinement loss (CL) is maintained at an ultra-low level, around 10⁻¹³ cm⁻¹, which is significantly better than previously reported sensors.
  • Effective Material Loss Differentiation: The EML shows distinct variations with different concentrations of DM and CHD markers, enabling accurate diagnosis and severity assessment. For instance, EML differs dramatically between normal and high levels of triglycerides.
  • Optimal Parameters: The optimal structural parameters identified are a core diameter of 520 µm, vertical support arm thickness of 25 µm, and horizontal support arm thickness of 20 µm.
  • Fabrication Tolerance: The designed MSF biosensor shows less than 1% deviation in performance with a 5% change in fiber geometries, indicating robustness to fabrication variations.

Limitations and Future Work

  • Simulation-Based: The study is primarily based on simulations. Experimental validation of the proposed design and its performance is the crucial next step.
  • Specific Markers: While the paper focuses on DM and CHD markers, future work could explore the detection of a broader range of biomarkers for other diseases.
  • Real-World Samples: The simulations used data from literature for marker properties. Testing with actual patient blood samples would provide a more realistic assessment of the sensor's performance.
  • Integration with THz-TDS: The paper suggests integration with a THz time-domain spectroscopy (THz-TDS) system for practical applications. Further research could focus on the development of such integrated systems.

Summary updated

BibTeX
@misc{xue2023ultra,
  author = {Jia Xue and Yani Zhang and Zhe Guang and Ting Miao and Zohaib Ali and Dun Qiao and Yiming Yao and Kexin Wu and Lei Zhou and Cheng Meng and Nigel Copner},
  title = {{Ultra-High Sensitivity Terahertz Microstructured Fiber Biosensor for Diabetes Mellitus and Coronary Heart Disease Marker Detection}},
  year = {2023},
  doi = {10.3390/s23042020},
}
Figure