U-Net and Its Variants Based Automatic Tracking of Radial Artery in Ultrasonic Short-Axis Views: A Pilot Study

Yuan Tian, Ruiyang Gao, Xinran Shi, Jiaxin Lang, Xue Yang, Chunrong Wang, Yuelun Zhang, Le Shen, Chunhua Yu, Zhuhuang ZhouDiagnostics 2024

TL;DR

This study explores the use of U-Net and its variants for automatically tracking the radial artery in ultrasound images, a crucial step for ultrasound-guided procedures. The research demonstrates that deep learning models, particularly Res-UNet, can achieve high accuracy in this task, paving the way for more automated and accessible medical interventions.

What Problem Does This Paper Address?

Ultrasound-guided radial artery catheterization (RAC) is a common and vital procedure in various medical settings, from anesthesiology to intensive care. Accurate tracking of the radial artery (RAT) in short-axis ultrasound views is the foundational step for successful RAC. However, manual RAT is time-consuming, requires significant expertise, and is prone to inter-observer variability due to factors like anatomical variations, image quality, and operator experience. This variability can lead to disparities in healthcare and hinder the development of fully automated procedures. The paper aims to address this by investigating the feasibility of using deep learning, specifically U-Net and its variants, for automated RAT.

Methods

The researchers employed several U-Net-based deep learning architectures for automatic radial artery tracking. These included the foundational U-Net, along with its enhanced versions: Attention U-Net, UNet++, Res-UNet, TransUNet, and UNeXt. The models were trained and validated on a custom dataset of radial artery ultrasound images. Performance was evaluated using standard segmentation metrics like the Dice Similarity Coefficient (DSC) and Jaccard Similarity Coefficient (JSC), as well as loss functions (binary cross-entropy and Dice loss). Statistical analysis, specifically the Kruskal-Wallis test, was used to compare the performance differences between the models.

Datasets

The study utilized a newly constructed dataset comprising 7233 images extracted from 178 videos of 135 patients undergoing potential radial artery catheterization. These videos were captured using three different ultrasound machines and various linear array probes. The dataset was randomly split into training (80%), validation (10%), and testing (10%) sets. This dataset represents a significant collection for radial artery ultrasound image segmentation research.

Key Insights and Ideas

  • Deep Learning for Radial Artery Tracking is Feasible: The study successfully demonstrates that U-Net and its variants can automate the critical task of radial artery tracking in ultrasound images.
  • Res-UNet Stands Out: Among the evaluated U-Net variants, Res-UNet consistently outperformed others in terms of segmentation accuracy (DSC and JSC). This suggests its architecture is particularly well-suited for the nuances of radial artery imaging.
  • Importance of Architectural Enhancements: While the base U-Net performs well, variants like Res-UNet show clear advantages, highlighting the impact of specific architectural modifications (e.g., residual blocks, attention mechanisms) on segmentation performance.
  • Addressing Inter-Observer Variability: By providing an automated solution, deep learning models have the potential to significantly reduce the inter-observer variability inherent in manual RAT, leading to more consistent and reliable procedures.

Key Results

The study found that all U-Net variants achieved consistent convergence of loss functions during training and validation, except for Attention U-Net. On the test set:

  • Res-UNet achieved the highest performance with a DSC of 93.14% ± 3.58% and a JSC of 87.93% ± 5.57%.
  • This performance was statistically significant compared to the baseline U-Net (DSC: 91.79% ± 8.51%) and Attention U-Net (DSC: 91.20% ± 7.49%).
  • Other variants like UNet++, TransUNet, and UNeXt also showed strong performance, though slightly lower than Res-UNet.
  • In terms of computational efficiency, UNeXt required the fewest parameters, Res-UNet had the fastest overall training time, and UNet++ had the lowest inference time per image.

Limitations and Future Work

The authors acknowledge several limitations and suggest future research directions:

  • Challenging Cases: The study identified specific challenging scenarios for current models, including distinguishing hypoechoic tissues from the radial artery, accurately identifying the artery when multiple vessels are present, and delineating ambiguous boundaries of tiny arteries.
  • Future Directions:
    • Multi-modality Fusion: Incorporating other ultrasound modalities like elastography or color Doppler imaging could help differentiate hypoechoic tissues from the radial artery.
  • Dataset Augmentation: Increasing the number of challenging cases (e.g., multiple vessels) in the training set could improve generalization.
  • Super-Resolution Techniques: Employing generative adversarial networks or super-resolution networks could enhance image resolution, making vessel boundaries more distinct.
  • Real-time Performance: Further optimization of model architectures (e.g., model compression, lightweight modules) is needed to achieve real-time RAT in clinical settings.

Summary updated

Abstract

<b>Background/Objectives:</b> Radial artery tracking (RAT) in the short-axis view is a pivotal step for ultrasound-guided radial artery catheterization (RAC), which is widely employed in various clinical settings. To eliminate disparities and lay the foundations for automated procedures, a pilot study was conducted to explore the feasibility of U-Net and its variants in automatic RAT. <b>Methods:</b> Approved by the institutional ethics committee, patients as potential RAC candidates were enrolled, and the radial arteries were continuously scanned by B-mode ultrasonography. All acquired videos were processed into standardized images, and randomly divided into training, validation, and test sets in an 8:1:1 ratio. Deep learning models, including U-Net and its variants, such as Attention U-Net, UNet++, Res-UNet, TransUNet, and UNeXt, were utilized for automatic RAT. The performance of the deep learning architectures was assessed using loss functions, dice similarity coefficient (DSC), and Jaccard similarity coefficient (JSC). Performance differences were analyzed using the Kruskal-Wallis test. <b>Results:</b> The independent datasets comprised 7233 images extracted from 178 videos of 135 patients (53.3% women; mean age: 41.6 years). Consistent convergence of loss functions between the training and validation sets was achieved for all models except Attention U-Net. Res-UNet emerged as the optimal architecture in terms of DSC and JSC (93.14% and 87.93%), indicating a significant improvement compared to U-Net (91.79% vs. 86.19%, <i>p</i> < 0.05) and Attention U-Net (91.20% vs. 85.02%, <i>p</i> < 0.05). <b>Conclusions:</b> This pilot study validates the feasibility of U-Net and its variants in automatic RAT, highlighting the predominant performance of Res-UNet among the evaluated architectures.