NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Toward Multimodal Conversational AI for Age-Related Macular Degeneration

Ran Gu, Benjamin Hou, Mélanie Hébert, Asmita Indurkar, Yifan Yang, Emily Y. Chew, Tiarnán D. L. Keenan, Zhiyong LuarXiv 2026

Here is a concise, engaging summary of the paper, tailored for a technically literate audience.

TL;DR

This paper introduces OcularChat, a multimodal large language model (MLLM) fine-tuned to diagnose age-related macular degeneration (AMD) from retinal images while providing interactive, clinically grounded dialogue. By bridging the gap between static image classification and conversational AI, OcularChat significantly outperforms state-of-the-art models in diagnostic accuracy and earns substantially higher marks from human ophthalmologists for its clinical reasoning.

What Problem Does This Paper Address?

Deep learning has excelled at automated medical image classification, but traditional models operate as "black boxes"—spitting out categorical predictions without explanation or context. In ophthalmology, diagnosing conditions like Age-Related Macular Degeneration (AMD) requires more than a simple label; clinicians must explain visual findings, answer patient questions, and map out risk factors.

While general-purpose vision-language models (VLMs) exist, they lack domain-specific training on retinal images and medical terminology, making them prone to clinical inaccuracies and hallucinations. The authors address this gap by creating a specialized AI assistant that combines high-accuracy AMD feature detection with the ability to engage in natural, clinically coherent patient-physician dialogue.

Methods

The researchers developed OcularChat by fine-tuning the open-source Qwen2.5-VL-32B model end-to-end. To teach the model how to converse like a clinician, they used GPT-4V to generate a massive dataset of 705,850 simulated patient-physician dialogues based on real clinical metadata (such as age, smoking status, and AMD severity).

The training data utilized two distinct conversational formats:

  1. Closed-format: Prompted the model to output structured JSON data, allowing for automated, large-scale accuracy testing against ground-truth reading center grades.
  2. Open-format: Simulated natural, multi-turn conversations about retinal findings to mimic real-world clinic visits.

The model was trained for two epochs using PyTorch on eight NVIDIA H100 GPUs with mixed-precision (bfloat16), directly aligning visual features from fundus images with conversational text.

Datasets

  • AREDS (Age-Related Eye Disease Study): The primary dataset containing 59,333 color fundus photographs (CFPs) from 4,107 participants. This was split at the participant level into a training set (46,167 CFPs) and a test set (13,166 CFPs) to prevent data leakage.
  • AREDS2: Used as an independent external validation cohort consisting of 3,872 CFPs from 831 participants to rigorously test the model's generalizability.

Key Insights and Ideas

  • Dialogue as a Supervision Signal: Instead of training on simple binary or categorical labels, embedding clinical knowledge within simulated multi-turn dialogues allows the MLLM to learn diagnostic features and communication strategies simultaneously.
  • The "Label vs. Reasoning" Disconnect: The study highlighted a crucial phenomenon: a model can correctly identify a diagnostic label (e.g., "no advanced AMD") but base its text explanation on the wrong features (focusing on early-stage drusen size instead of explicitly ruling out advanced features like geographic atrophy). This underscores the vital importance of clinician-in-the-loop evaluation over pure accuracy metrics.
  • Mitigating Hallucinations through Focus: While general-purpose models often produce verbose, hallucination-prone responses filled with irrelevant anatomical descriptions, OcularChat’s domain-specific fine-tuning resulted in concise, task-focused answers better suited for clinical screening workflows.

Key Results

  • Objective Accuracy: On the AREDS test set, OcularChat achieved remarkable accuracies of 0.954 for advanced AMD detection, 0.849 for pigmentary abnormalities, and 0.678 for drusen size categorization, significantly outperforming general-domain giants like GPT-o1 and medical models like MedGemma-4B.
  • External Validation: OcularChat maintained its top-performing status on the external AREDS2 dataset, demonstrating superior generalizability and less performance degradation than its competitors.
  • Subjective Expert Evaluation: In a blinded study with three independent ophthalmologists using a 5-point Likert scale, OcularChat consistently beat the baseline model across all categories, including advanced AMD identification (3.503 vs. 2.833) and overall clinical impression (2.978 vs. 2.464). It also demonstrated an inter-rater agreement (Cohen's kappa) over 20% higher than the baseline.

Limitations and Future Work

  • Single Modality Constraint: OcularChat was trained exclusively on Color Fundus Photographs (CFPs). While excellent for low-cost screening, CFPs miss the 3D structural details provided by Optical Coherence Tomography (OCT), which is critical for the early diagnosis of neovascular late AMD.
  • Semantic Misalignment: The model occasionally conflated early-stage features with advanced AMD criteria in its text explanations, showing that stage-appropriate reasoning still needs refinement.
  • Balancing Conciseness and Depth: Clinician preferences varied; some preferred concise answers for quick screening, while others wanted highly detailed, image-grounded reasoning. The authors suggest that future iterations should include configurable explanation depths to satisfy different clinical use cases.

Summary updated

BibTeX
@misc{gu2026toward,
  author = {Ran Gu and Benjamin Hou and Mélanie Hébert and Asmita Indurkar and Yifan Yang and Emily Y. Chew and Tiarnán D. L. Keenan and Zhiyong Lu},
  title = {{Toward Multimodal Conversational AI for Age-Related Macular Degeneration}},
  year = {2026},
  eprint = {2604.25720},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2604.25720},
}

Loading related content...