TotalSegmentator Aorta Report: Automated Aortic Diameter Measurement at 11 Standardized Landmarks on CT Images

Jakob Wasserthal, Daniel Hinck, Martin Segeroth, Joshy Cyriac, Denis Berdajs, Jules Miazza, Maurice PradellaarXiv 2026

TL;DR

Researchers have released an open-source extension to the popular TotalSegmentator tool that automatically measures aortic diameters at 11 key clinical landmarks. With an average error of just ~1 mm, it outperforms typical human inter-reader variability and provides a robust, standardized way to track aortic health from the heart to the abdomen.

What Problem Does This Paper Address?

Measuring the aorta isn't just about finding the "widest part." Clinical guidelines require radiologists to measure diameters at specific, standardized anatomical landmarks—such as the aortic annulus or the celiac trunk origin—measured perpendicular to the vessel's centerline.

Doing this manually is a tedious process involving "double-oblique" reconstructions that are prone to significant human error. In fact, measurements between different doctors can vary by 1.6–5 mm on the same scan, which is often in the same range as the annual growth rate they are trying to monitor. While AI tools exist, many are proprietary, limited to the chest area, or don't follow these strict landmarking guidelines for the entire aorta.

Methods

The authors built upon TotalSegmentator, a widely used open-source AI for medical image segmentation. Their "Aorta Report" pipeline uses five specialized deep learning models (based on the nnU-Net framework) to segment the aorta, its major branches, the heart, and the vertebrae.

The core innovation is the automated landmarking: the tool extracts the aortic centerline and uses the segmented branches (like the brachiocephalic trunk or renal arteries) and vertebrae as "anchors" to place 11 standardized measurement planes. At each plane, it calculates the maximum and perpendicular diameters.

Figure 2: Example output of the aorta report in a 46-year-old male patient at ECG-gated arterial phase CT angiography. Left: three-dimensional rendering of the aortic segmentation with the centerline (red dashed line) and the measurement planes at landmarks 1–11. Right: cross-sections perpendicular to the centerline at each landmark, with the cross-sectional area and the maximum and perpendicular diameters (green lines). ECG = electrocardiography.

Datasets

The tool was evaluated on a retrospective dataset of 239 arterial phase CT angiography (CTA) examinations from 230 patients (median age 65). To create a "ground truth" reference standard, a senior radiologist reviewed and, where necessary, corrected the AI's automated measurements.

Key Insights and Ideas

  • Clinical Alignment: By using 11 specific landmarks (defined in Table 2), the tool directly supports structured clinical reporting. This makes longitudinal follow-up—comparing the exact same anatomical spot over years—much more reliable than manual "eyeballing."
  • The "Thrombus" Challenge: Accuracy dropped significantly in the presence of mural thrombus (blood clots on the vessel wall). The AI and the radiologist sometimes disagreed on the boundary, highlighting a need for clearer definitions in automated systems regarding "outer wall" vs. "patent lumen" measurements.
  • Open Science: Unlike commercial "black-box" solutions, this tool is fully open-source and integrated into a popular framework, allowing the global research community to inspect, validate, and adapt the code.

Key Results

The performance was highly competitive with human experts:

  • High Accuracy: The Mean Absolute Error (MAE) across all landmarks was 1.06 mm. Impressively, 86.6% of measurements were within the 2 mm threshold often cited as the limit of human reproducibility.
  • Reliability: The tool only failed to provide a measurement in 1.2% of landmarks across the entire study.
  • Regional Performance: The system was most accurate in the mid-ascending to descending aorta (MAE as low as 0.26 mm).
  • The Root remains hard: The sinuses of Valsalva (the aortic root) had the highest error (MAE 2.17 mm), likely due to its complex trilobed shape and cardiac motion.
Figure 3: Difference between the maximum diameter of the aorta report and the reference at each landmark. Each dot is one examination, and black bars are the mean difference. Positive values mean the aorta report measured larger. The gray band marks differences of 2 mm or less. Both diameters were available in whole millimeters, so a small vertical jitter (±0.25 mm) was added for display. The y-axis is limited to the 2nd to 98th percentile of all differences, widened by 1 mm (−4 to 6 mm). The 70 of 2355 differences (3.0%) beyond these limits are shown as black triangles at the limit and labeled with their values in millimeters, or with their number (n) and range if there are more than two. Means include all differences.

Limitations and Future Work

The authors acknowledge several areas for improvement. First, the reference standard was created by correcting the AI's output rather than measuring independently, which might bias results toward the tool for very small differences. Second, the study was conducted at a single center primarily using one scanner model; multi-center validation is essential.

Finally, while the tool is designed to work on any CT image, this study only evaluated arterial phase CTA. Future work will need to confirm its performance on non-contrast or venous phase scans, which are common in routine clinical practice.

The code is freely available at https://github.com/wasserth/TotalSegmentator.

Summary updated

BibTeX
@misc{wasserthal2026totalsegmentator,
  author = {Jakob Wasserthal and Daniel Hinck and Martin Segeroth and Joshy Cyriac and Denis Berdajs and Jules Miazza and Maurice Pradella},
  title = {{TotalSegmentator Aorta Report: Automated Aortic Diameter Measurement at 11 Standardized Landmarks on CT Images}},
  year = {2026},
  eprint = {2611.17968},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.17968},
}
Figure