Top-K Maximum Intensity Projection Priors for 3D Liver Vessel Segmentation

Xiaotong Zhang, Alexander Broersen, Gonnie van Erp, Silvia L. Pintea, Jouke DijkstraarXiv 2025 · DOI · arXiv

TL;DR

This paper introduces a novel "top-k maximum intensity projection" (top-k MIP) method to improve 3D liver vessel segmentation. By mimicking CT reconstruction physics, their approach better captures global vessel topology, leading to state-of-the-art segmentation accuracy on the 3D-ircadb-01 dataset.

What Problem Does This Paper Address?

Accurate segmentation of liver vessels is crucial for pre-operative planning of liver resection, particularly to minimize blood loss. Existing methods often rely on 2D or 3D convolutional neural networks (CNNs) that process cropped sub-volumes of CT scans. While effective for local details, these approaches can fail to preserve the global topology of the complex liver vessel network, leading to discontinuous or incomplete segmentations. Previous attempts to incorporate global topology using standard Maximum Intensity Projection (MIP) have been limited, often requiring combination with other 3D methods. This paper aims to address this gap by developing a method that inherently captures global vessel structure within a unified framework.

Methods

The core innovation is the "top-k maximum intensity projection" (top-k MIP). Unlike standard MIP, which only retains the single maximum voxel value along a projection direction, top-k MIP preserves the top-k maximum values. This approach is inspired by the underlying physics of CT reconstruction, where integrals along projection directions are used to reconstruct a 3D volume. The authors propose using these top-k MIPs as a conditioning signal for a latent diffusion model (LDM).

Here's a breakdown of their pipeline:

  1. Top-k MIP Generation: For a given 3D CT volume, they compute top-k MIPs along multiple projection directions. This captures more detailed structural information than standard MIP.
  2. Latent Diffusion Model (LDM) Conditioning: These top-k MIPs are encoded into a latent representation (c'). This latent representation then conditions an LDM.
  3. 3D Vessel Tree Reconstruction: The LDM is trained to denoise noisy inputs (integral projections of the ground truth vessel tree) into a clean estimate of the vessel tree's integral projections (xˆ0).
  4. Post-processing: Filtered back projection (FBP) is used to reconstruct the 3D vessel tree from the estimated integral projections. An optimization step is included to suppress artifacts that can arise from projection inconsistencies, followed by connected region analysis to remove spurious predictions.

Datasets

The primary dataset used for evaluation is the 3D-ircadb-01 dataset. This dataset consists of 20 CT scans. The authors note that small liver vessel annotations in this dataset can be incomplete. To address this, they selected a subset of cases (4, 6, 8, 11, 16) with annotations scored ≥ 4 by clinical experts for their test set. They employed a leave-one-out cross-validation strategy.

Key Insights and Ideas

  • Mimicking CT Physics for Topology: The paper's central idea is that by drawing inspiration from the physical principles of CT reconstruction (using projections), they can effectively encode global 3D topology. This is a clever way to leverage existing knowledge about how medical images are formed.
  • Top-k MIP for Richer Priors: The "top-k" aspect is crucial. It allows the model to retain more nuanced structural information than a simple maximum, which is vital for segmenting complex, branching structures like blood vessels. This richer prior helps the diffusion model generate more complete and accurate segmentations.
  • Diffusion Models as Powerful Generators: The use of a latent diffusion model, conditioned on these novel top-k MIP priors, proves to be a highly effective generative approach for reconstructing the 3D vessel tree.
  • Artifact Suppression is Necessary: The inclusion of an artifact suppression step highlights a practical challenge in reconstructing 3D volumes from projections, especially when dealing with potentially noisy or inconsistent input data.

Key Results

The proposed top-k MIP method achieved state-of-the-art results on the 3D-ircadb-01 dataset, outperforming several strong baselines including nnUNet, SwinUNetr, EnsemDiff, and MedSegDiff. Specifically, their model achieved the highest:

  • Dice Coefficient (DSC): 64.25 ± 7.19%
  • Intersection-over-Union (IoU): 47.75 ± 8.00%
  • Sensitivity (Sen): 54.03 ± 11.23%

While nnUNet had a higher centerline Dice coefficient (clDice), the authors suggest this might be due to annotation inaccuracies and that their method produces more connected vessel structures. The artifact suppression step significantly improved the quality of the reconstructed vessel IPs, as evidenced by higher PSNR and SSIM scores.

Limitations and Future Work

The authors acknowledge several limitations and suggest future directions:

  • Low-Contrast Regions: The model struggles with segmenting extremely low-contrast vascular regions, as illustrated in Fig. 6.

  • Independent Projection Processing: Currently, each projection view is processed independently. The authors suggest that strengthening the correlation between projection views could lead to improvements.

  • Dynamic Projection Strategy: Developing a dynamic projection strategy for top-k MIP generation is another avenue for future work.
  • Standard MIP Potential: A model that better captures inter-projection correlations might enable the use of standard MIP, which currently collapses depth information.

Summary updated

Abstract

Liver-vessel segmentation is an essential task in the pre-operative planning of liver resection. State-of-the-art 2D or 3D convolution-based methods focusing on liver vessel segmentation on 2D CT cross-sectional views, which do not take into account the global liver-vessel topology. To maintain this global vessel topology, we rely on the underlying physics used in the CT reconstruction process, and apply this to liver-vessel segmentation. Concretely, we introduce the concept of top-k maximum intensity projections, which mimics the CT reconstruction by replacing the integral along each projection direction, with keeping the top-k maxima along each projection direction. We use these top-k maximum projections to condition a diffusion model and generate 3D liver-vessel trees. We evaluate our 3D liver-vessel segmentation on the 3D-ircadb-01 dataset, and achieve the highest Dice coefficient, intersection-over-union (IoU), and Sensitivity scores compared to prior work.
BibTeX
@misc{zhang2025top,
  author = {Xiaotong Zhang and Alexander Broersen and Gonnie van Erp and Silvia L. Pintea and Jouke Dijkstra},
  title = {{Top-K Maximum Intensity Projection Priors for 3D Liver Vessel Segmentation}},
  year = {2025},
  eprint = {2503.03367},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2503.03367},
  howpublished = {arXiv},
}
Figure