Theoretical and experimental study of the microwave cut-off probe for electron density measurements in low-temperature plasmas
Lists
Only you see this
Abstract
The microwave cut-off probe for the electron density measurement in low-temperature plasmas is described in this article. It is based on the wave cutoff in an unmagnetized plasma. The measurement principle is analyzed theoretically using a model of plasma slab. Because of the high-pass characteristic of plasma, the waves above the cut-off frequency can penetrate the plasma slab, whereas the lower frequency waves are reflected from the cut-off layer. Therefore, an obvious critical point can be observed in the wave transmission spectrum. The abscissa of the critical point indicates the cut-off frequency, which is directly related to the maximum electron density between transmitting/receiving antennas of the cut-off probe. The measured electron densities are in agreement with the data obtained by the Langmuir probe. Experimental results show that the microwave cut-off probe can be used to diagnose the plasmas with a wide range of parameters.
BibTeX
@article{li2011theoretical,
author = {Bin Li and Hong Li and Huihui Wang and Jinlin Xie and Wandong Liu},
title = {{Theoretical and experimental study of the microwave cut-off probe for electron density measurements in low-temperature plasmas}},
journal = {Journal of Applied Physics},
year = {2011},
doi = {10.1063/1.3647760},
}Loading related content...