NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

The x-ray microcalorimeter spectrometer onboard Athena

J. W. den Herder, D. Bagnali, S. R. Bandler, Marco Barbera, X. Barcons, D. Barret, Paolo Bastia, M. Bisotti, K. R. Boyce, C. Cara, M. T. Ceballos, L. Corcione, Beatriz Cobo, L. Colasanti, J. de Plaa, Michael DiPirro, W. B. Doriese, Yuichiro Ezoe, Ryuichi Fujimoto, F. Gatti, Luciano Gottardi, P. Guttridge, R. den Hartog, I. D. Hepburn, Richard L. Kelley, K. D. Irwin, Yoshitaka Ishisaki, Caroline A. Kilbourne, P. A. J. de Korte, J. van der Kuur, Simone Lotti, C. Macculi, Kazuhisa Mitsuda, T. Mineo, L. Natalucci, T. Ohashi, M. J. Page, S. Paltani, E. Perinati, L. Piro, C. Pigot, F. S. Porter, G. Rauw, Laurent Ravera, Étienne Renotte, J. L. Sauvageot, Christian Schmid, S. Sciortino, Peter Shirron, Yoh Takei, G. Torrioli, Masahiro Tsujimoto, L. Valenziano, Dick Willingale, C. de Vries, H. van Weers, J. Wilms, Noriko Y. YamasakiProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 2012

Abstract

One of the instruments on the Advanced Telescope for High-Energy Astrophysics (Athena) which was one of the three missions under study as one of the L-class missions of ESA, is the X-ray Microcalorimeter Spectrometer (XMS). This instrument, which will provide high-spectral resolution images, is based on X-ray micro-calorimeters with Transition Edge Sensor (TES) and absorbers that consist of metal and semi-metal layers and a multiplexed SQUID readout. The array (32 x 32 pixels) provides an energy resolution of < 3 eV. Due to the large collection area of the Athena optics, the XMS instrument must be capable of processing high counting rates, while maintaining the spectral resolution and a low deadtime. In addition, an anti-coincidence detector is required to suppress the particle-induced background. Compared to the requirements for the same instrument on IXO, the performance requirements have been relaxed to fit into the much more restricted boundary conditions of Athena. In this paper we illustrate some of the science achievable with the instrument. We describe the results of design studies for the focal plane assembly and the cooling systems. Also, the system and its required spacecraft resources will be given.
BibTeX
@inproceedings{herder2012x,
  author = {J. W. den Herder and D. Bagnali and S. R. Bandler and Marco Barbera and X. Barcons and D. Barret and Paolo Bastia and M. Bisotti and K. R. Boyce and C. Cara and M. T. Ceballos and L. Corcione and Beatriz Cobo and L. Colasanti and J. de Plaa and Michael DiPirro and W. B. Doriese and Yuichiro Ezoe and Ryuichi Fujimoto and F. Gatti and Luciano Gottardi and P. Guttridge and R. den Hartog and I. D. Hepburn and Richard L. Kelley and K. D. Irwin and Yoshitaka Ishisaki and Caroline A. Kilbourne and P. A. J. de Korte and J. van der Kuur and Simone Lotti and C. Macculi and Kazuhisa Mitsuda and T. Mineo and L. Natalucci and T. Ohashi and M. J. Page and S. Paltani and E. Perinati and L. Piro and C. Pigot and F. S. Porter and G. Rauw and Laurent Ravera and Étienne Renotte and J. L. Sauvageot and Christian Schmid and S. Sciortino and Peter Shirron and Yoh Takei and G. Torrioli and Masahiro Tsujimoto and L. Valenziano and Dick Willingale and C. de Vries and H. van Weers and J. Wilms and Noriko Y. Yamasaki},
  title = {{The x-ray microcalorimeter spectrometer onboard Athena}},
  booktitle = {Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE},
  year = {2012},
  doi = {10.1117/12.924269},
}

Loading related content...