Abstract As a critical device for blast furnace gas dust removal, the development of the annular gap scrubber aims to reduce equipment pressure loss and water consumption while ensuring dust removal rate. In this study, numerical simulations of the two-phase flow field within the scrubber were conducted to calculate the pressure loss of the existing equipment under the target dust removal rate. Based on the design principles of a Venturi tube and simulation results, the scrubber’s structure was optimized. The optimized design significantly reduced pressure loss under various operating conditions, with an average reduction of over 10% and a maximum reduction of 15.83%. Additionally, dust removal performance improved at low water-gas ratios. The new design increased the gas residual pressure power generation efficiency by approximately 1.9%, resulting in an additional power output of around 200 kW. This study provides a new optimization strategy for the structural parameters of the annular gap scrubber, contributing to enhanced energy efficiency and reduced resource waste in the steel industry.