The Relationship Between PM2.5 and the Action Spectrum of Ultraviolet Radiation for Vitamin D Production Based on a Manikin Model
Lists
Only you see this
Abstract
Objectives: Fine particulate matter (PM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2.5</sub> ) is the principal air pollutant and poses a serious threat to public health. This study explored the effects of PM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2.5</sub> on the action spectrum of ultraviolet radiation for vitamin D production (UV <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">vitD</sub> ) received by manikin surfaces. Methods: Multi-inclination angle ultraviolet radiation monitoring was conducted with different concentrations of PM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2.5</sub> . Combining monitoring data with the PM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2.5</sub> concentration, solar elevation angle (SEA), and inclination angle, a UV <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">vitD</sub> exposure model for human body multi-inclined surfaces was constructed through a multiple linear regression analysis. A 3D manikin model was used to examine the PM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2.5</sub> effects on UV <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">vitD</sub> received by the manikin surface. Results: When PM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2.5</sub> concentrations ranged from 35 μg/m <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> to 100 μg/m <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> (average concentration of PM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2.5</sub> in this range: 62 μg/m <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> ), the UV <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">vitD</sub> received by the whole body was reduced by approximately 8.45% to 19.82% compared with the UV <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">vitD</sub> received when PM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2.5</sub> concentrations ranged from 6 μg/m <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> to 35 μg/m <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> (average concentration of PM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2.5</sub> in this range: 17 μg/m <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> ) with SEAs between 30° and 50°. Moreover, the UV <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">vitD</sub> dose was reduced by 11.82% in the above comparisons. When further comparing PM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2.5</sub> concentrations from 100 μg/m <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> to 161 μg/m <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> (average concentration of PM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2.5</sub> in this range: 132 μg/m <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> ) with those from 6 μg/m <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> to 35 μg/m <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> (average concentration of PM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2.5</sub> in this range: 17 μg/m <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> ), the UV <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">vitD</sub> received by the whole body was reduced by approximately 21.6% to 50.64% at SEAs between 30° and 50°. The UVvitD dose was reduced by 30.2%. Conclusions: The occurrence of PM <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2.5</sub> obviously reduced the UV <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">vitD</sub> received by the manikin surface.
BibTeX
@inproceedings{wang2020relationship,
author = {Nan Wang and Menglin Li and Liting Huang and Zhenzhen Zou and Yan Deng and Yang Liu and Rentong Chen and Yan Liu and Jiaming Yu and Tianyao Yang and Hui Hua and Dan Yang and Fangfang Ma and Xin Li},
title = {{The Relationship Between PM2.5 and the Action Spectrum of Ultraviolet Radiation for Vitamin D Production Based on a Manikin Model}},
booktitle = {IEEE Access},
year = {2020},
url = {https://openreview.net/forum?id=198zZXbNUsP},
}Loading related content...