The photometric calibration of the ISO Short Wavelength Spectrometer
Lists
Only you see this
Abstract
We give an overview of the photometric calibration of the Short Wavelength Spectrometer (SWS) through the Performance Verification phase. The basic strategy for deriving absolute flux densities from detector output for the grating and Fabry-Perot sections of SWS is reviewed, and the results are demonstrated with 2.4 - 45 mu m spectra of representative standards gamma Dra, alpha Lyr, and gamma Cru. The effects of in-orbit changes in the relative spectral response function (RSRF) and ISO pointing are discussed. The systematic continuum flux level uncertainties (1 sigma) are within the pre-launch specification of 30%. Further improvements depend on characterization of the in-orbit RSRF improved performance of ISO pointing, and new data processing techniques.
BibTeX
@inproceedings{schaeidt1996photometric,
author = {S. Schaeidt and P. W. Morris and A. Salama and B. Vandenbussche and D. A. Beintema and Danny Boxhoorn and H. Feuchtgruber and A. M. Heras and F. Lahuis and K. Leech and Pieter R. Roelfsema and E. A. Valentijn and O. H. Bauer and N. S. van der Bliek and M. Cohen and Th. de Graauw and L. Haser and K. A. van der Hucht and E. Huygen and R. O. Katterloher and Martin Kessler and J. Koornneef and W. Luinge and D. Lutz and Max Planck and H. W. W. Spoon and C. Waelkens and L. B. F. M. Waters and E. Wieprecht and K. J. Wildeman and Eric W. Young and P. Zaal},
title = {{The photometric calibration of the ISO Short Wavelength Spectrometer}},
booktitle = {University},
year = {1996},
}Loading related content...