NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

The optimisation of chromatographic conditions for the determination of acceptor-donor properties of graphene oxide and reduced graphene oxide

H. Grajek, Justyna Janik, Leszek Rutkowski, Marcin Purchała, Tomasz WawerActa Innovations 2018

Abstract

The oxidised and reduced graphene samples (having different surface functionalities) were studied by inverse gas chromatography to characterise their acceptor-donor properties. The DN values denoting the donor number in the Gutmann scale and the AN* values denoting the acceptor number in the Riddle-Fowkes scale have been chosen in the estimation of the electron-acceptor parameter $K_A$ and electron-donor parameter $K_D$ values.

Introduction

While graphene is celebrated for its bulk properties like high conductivity and strength, its real-world performance in composites, sensors, and energy storage depends heavily on its surface chemistry. Specifically, the interaction between functional groups (such as carboxyl or ketone groups) and other molecules determines the material's efficacy in various applications. Characterizing these "acceptor-donor" properties—the tendency of a surface to give or receive electrons—is notoriously difficult, as standard methods often fail to capture the nuance of surface functionalities. This study addresses the challenge of optimizing chromatographic conditions to extract reliable thermodynamic data, allowing for the categorization of graphene oxide (GO) and reduced graphene oxide (rGO) on a scale of acidity and basicity.

Methods

The researchers employed Inverse Gas Chromatography at Infinite Dilution (IGC-ID). Unlike standard GC, where a known column identifies an unknown gas, IGC involves packing the column with the material of interest (GO or rGO) and injecting known "probe" molecules. By measuring the retention times of these probes, the surface's energetic properties can be calculated.

Key technical highlights include:

  • Mathematical Modeling: Advanced functions (P4 and ExtraVal4T) were used to describe elution peak profiles, accounting for flow disturbances and non-ideal conditions to ensure accurate retention times.
  • Thermodynamic Mapping: Specific retention volumes ($V_g$) were calculated across a temperature range of 130°C to 150°C to derive the molar differential enthalpy ($\Delta H$), entropy ($\Delta S$), and Gibbs free energy ($\Delta G$) of adsorption.
  • Parameter Estimation: The Gutmann donor number ($DN$) and Riddle-Fowkes acceptor number ($AN^*$) were utilized to calculate specific electron-acceptor ($K_A$) and electron-donor ($K_D$) parameters.
Temperature dependence of the specific retention volume (Vg) for n-alkanes.

Results and Discussion

Thermodynamic Compensation Effect

A critical finding of the study was the confirmation of the thermodynamic compensation effect. The authors observed a strong linear relationship between the entropy and enthalpy of adsorption ($-\Delta S_{ADS} = f(-\Delta H_{ADS})$). This linear correlation indicates that the experimental conditions were correctly optimized for ideal, non-linear chromatography, ensuring the reliability of the derived parameters.

Thermodynamic compensation effect for graphene oxide (GO), showing the linear relationship between adsorption entropy and enthalpy.

Surface Basicity and the Role of Oxygen

The study successfully classified both GO and rGO as basic surfaces. In surface science, a $K_A/K_D$ ratio of less than 0.9 indicates a basic (electron-donor) surface. Both materials fell well within this range. Notably, GO exhibited stronger basic properties than rGO. This is attributed to the high density of oxygen-rich functional groups (carboxylic and ketone groups) in GO; the lone electron pairs on these oxygen atoms act as active donor sites.

While the reduction process from GO to rGO significantly alters these parameters, it does not flip the surface character from basic to acidic; rather, it primarily changes the magnitude of the interaction. Furthermore, a massive disparity in specific surface area was noted: GO measured at $2\text{ m}^2/\text{g}$, while rGO increased to $321\text{ m}^2/\text{g}$, highlighting the profound physical and chemical structural changes induced by reduction.

Conclusion

This research provides a robust framework for quantifying the acceptor-donor properties of graphene-based materials. By optimizing IGC conditions, the study demonstrated that both GO and rGO are inherently basic, with GO's oxygen functionalities providing stronger donor character. While the study quantifies electron exchange, the exact molecular mechanisms of electron transfer remain a subject for future investigation. Subsequent work should focus on elucidating these mechanisms and testing how various synthesis methods influence $K_A$ and $K_D$ values for industrial quality control.

Summary updated

BibTeX
@inproceedings{grajek2018optimisation,
  author = {H. Grajek and Justyna Janik and Leszek Rutkowski and Marcin Purchała and Tomasz Wawer},
  title = {{The optimisation of chromatographic conditions for the determination of acceptor-donor properties of graphene oxide and reduced graphene oxide}},
  booktitle = {Acta Innovations},
  year = {2018},
  doi = {10.32933/actainnovations.26.1},
}
Figure