The mean point of vergence is biased under projection

Xi Wang, Kenneth Holmqvist, Marc AlexaJournal of Eye Movement Research 2019

TL;DR

Eye-tracking systems often estimate a person's gaze point by calculating the intersection of their eye rays. This paper reveals that this common method introduces a systematic bias, particularly in depth, due to noise in the eye-tracking data. The authors propose a simple averaging technique to mitigate this bias, which is crucial for accurate 3D gaze estimation.

What Problem Does This Paper Address?

Estimating a person's gaze point in 3D space using eye-tracking technology is a fundamental task in many fields, from HCI to neuroscience. A standard approach involves using the two eye rays (lines of sight) from the observer's eyes and finding a point that is "closest" to both. However, real-world eye-tracking data is never perfect; it contains inaccuracies (systematic errors) and imprecisions (noise). These imperfections mean the two eye rays rarely intersect perfectly. The paper addresses the problem of how these inherent errors in eye-tracking data systematically affect the calculated 3D gaze point, specifically focusing on the "vergence point" – the point estimated to be closest to both eye rays. The core challenge is that the common method of calculating this point can introduce a predictable bias, especially in the depth dimension, which can lead to misinterpretations of gaze behavior.

Methods

The authors employ a two-pronged approach:

  1. Theoretical Analysis and Synthetic Simulations: They first develop a mathematical model to analyze how noise in eye-tracking data (specifically, errors in the direction of the eye rays) affects the calculated vergence point. They use synthetic simulations to visualize and quantify this bias, exploring how different distributions of horizontal versus vertical noise impact the results. They derive equations for the projectors of gaze vectors and the calculation of the closest point to two skew lines.
  2. Real Experimental Data Analysis: They then validate their theoretical findings using real human eye-tracking data. They analyze the raw pupil and corneal reflection data (without relying on the eye-tracker's internal calibration) to characterize the actual noise distributions. They compare these distributions across different viewing conditions and distances.

A key methodological contribution is the development of a method to estimate the vergence point by finding the point that minimizes the sum of squared distances to the two eye rays. They also propose a practical solution to reduce the bias: averaging multiple fixation samples from the same target.

Datasets

The study utilizes two main sources of data:

  • Synthetic Data: Generated through simulations based on the theoretical model, allowing for controlled manipulation of noise parameters (standard deviations for horizontal and vertical errors).
  • Human Experimental Data: Collected from 25 participants using an EyeLink 1000 desktop mount system. Participants performed fixation tasks at different distances (0.7m and 1.1m). The raw pupil minus corneal reflection data was analyzed.

No new benchmarks were introduced; rather, the study focuses on analyzing existing eye-tracking data and simulating error conditions.

Key Insights and Ideas

  • The "Vergence Point" is Inherently Biased: Even with perfectly symmetric noise distributions, the calculated point of closest approach between two imperfect eye rays is not the true target. This bias is particularly pronounced in the depth dimension.
  • Noise Direction Matters: The bias is not uniform; it depends critically on whether the noise is predominantly horizontal or vertical. Horizontal noise tends to push the estimated point further away from the observer, while vertical noise pulls it closer.
  • Distance Amplifies Bias: The further away the target, the larger the bias in the estimated vergence point becomes. This is an important consideration for studies involving distant targets.
  • Averaging is Key: The most effective way to mitigate this bias is to average multiple fixation samples from the same target. This is because averaging in the calibration space (raw eye data) leads to a better approximation of the true gaze direction, whereas averaging in the estimated 3D space can introduce its own biases due to the non-linear nature of projection.
  • Calibration Models are Part of the Experiment: The findings suggest that researchers should consider the mathematical models underlying eye-tracker calibration as an integral part of their experimental design and interpretation, rather than just a black box.

Key Results

  • Simulation Results: Showed that horizontal noise shifts the mean vergence point away from the viewer, while vertical noise shifts it towards the viewer. This effect was more pronounced at greater distances. For instance, at 110cm, the bias could be as high as 49% of the target distance.
  • Human Data Analysis: Confirmed the existence of a bias in real-world data. While individual differences in noise distributions were observed, the general trend of bias towards the observer was consistent.
  • Proposed Solution: Averaging multiple fixation samples per target significantly reduced the error in depth estimation, as demonstrated in Figure 11.

Limitations and Future Work

  • Limitations:
    • The study primarily used independent Gaussian distributions for horizontal and vertical noise. Future work could explore multivariate distributions and their impact.
  • The experiment used targets on a flat plane, not in true 3D space with dynamic focus changes. Collecting 3D fixation data with consistent precision remains a challenge.
  • The study did not account for fixation disparity, which is the difference in gaze direction between the two eyes when fixating on a target.
  • Eye dominance was self-reported and might not perfectly reflect actual dominance.
  • Future Work:
    • Investigate the dependency between horizontal and vertical noise distributions.
  • Explore how dynamic changes in focus and pupil size affect noise distributions.
  • Validate the proposed averaging method with real human data across various experimental setups.
  • Incorporate fixation disparity into the analysis.
  • Future studies should provide error distributions (e.g., error ellipses) rather than just scalar error metrics to better represent calibration accuracy.
  • Investigate whether the observed bias is similar across different types of eye-tracking devices and experimental tasks.

Summary updated

Abstract

The point of interest in three-dimensional space in eye tracking is often computed based on intersecting the lines of sight with geometry, or finding the point closest to the two lines of sight. We first start by theoretical analysis with synthetic simulations. We show that the mean point of vergence is generally biased for centrally symmetric errors and that the bias depends on the horizontal vs. vertical noise distribution of the tracked eye positions. Our analysis continues with an evaluation on real experimental data. The estimated mean vergence points seem to contain different errors among individuals but they generally show the same bias towards the observer. And it tends to be larger with an increased viewing distance. We also provided a recipe to minimize the bias, which applies to general computations of gaze estimation under projection. These findings not only have implications for choosing the calibration method in eye tracking experiments and interpreting the observed eye movements data; but also suggest to us that we shall consider the mathematical models of calibration as part of the experiment.
BibTeX
@article{wang2019mean,
  author = {Xi Wang and Kenneth Holmqvist and Marc Alexa},
  title = {{The mean point of vergence is biased under projection}},
  journal = {Journal of Eye Movement Research},
  year = {2019},
  doi = {10.16910/jemr.12.4.2},
}
Figure