The KATRIN superconducting magnets: overview and first performance results

M. Arenz, Woo-Jeong Baek, M. Beck, A. Beglarian, J. Behrens, Thaisa Storchi‐Bergmann, A. I. Berlëv, U. Besserer, K. Blaum, T. Bode, B. Bornschein, L. Bornschein, T. Brunst, N. Buzinsky, S. Chilingaryan, W. Choi, M. Deffert, P. J. Doe, O. Dragoun, G. Drexlin, S. Dyba, F. Edzards, K. Eitel, E. Ellinger, R. Engel, S. Enomoto, M. Erhard, D. Eversheim, M. Fedkevych, J. A. Formaggio, F. M. Fränkle, G. Franklin, F. Friedel, A. Fulst, W. Gil, F. Glück, A. González Ureña, S. Grohmann, Robin Größle, R. Gumbsheimer, M. Hackenjos, V. Hannen, F. Harms, N. Haußmann, F. Heizmann, K. Helbing, Werner Herz, S. Hickford, D. Hilk, M. A. Howe, A. Huber, A. Jansen, J. Kellerer, N. Kernert, L. Kippenbrock, M. Kleesiek, Manuel Klein, A. Kopmann, M. Korzeczek, A. Kovalík, B. Krasch, M. Kraus, L. Kuckert, T. Lasserre, O. Lebeda, J. Letnev, Alexey Lokhov, M. Machatschek, A. Marsteller, E. L. Martín, S. Mertens, S. Mirz, B. Monreal, H. Neumann, S. Niemes, A. Off, A. Osipowicz, E. Otten, D. S. Parno, A. Pollithy, A. W. P. Poon, F. Priester, P. C.-o. Ranitzsch, O. Rest, R. G. H. Robertson, Federico Roccati, C. Rodenbeck, M. Röllig, C. Röttele, M. Ryšavý, R. Sack, Alejandro Sáenz, L. Schimpf, K. Schlösser, Magnus Schlösser, K. Schönung, M. Schrank, Hendrik Seitz-Moskaliuk, J. Sentkerestiová, V. V. SinevJournal of Instrumentation 2018 · DOI

TL;DR

The KATRIN experiment aims to measure the electron antineutrino mass with unprecedented sensitivity. This paper details the design, construction, and initial performance of the complex superconducting magnet system required to guide electrons from the source to the detector. The results demonstrate the successful operation of these magnets, crucial for achieving the experiment's scientific goals.

What Problem Does This Paper Address?

Determining the absolute neutrino mass is a fundamental goal in particle physics and cosmology. The KATRIN experiment is designed to achieve this by measuring the shape of the tritium beta-decay spectrum near its endpoint with sub-eV sensitivity. This requires guiding a very low flux of beta-electrons (about 10⁻¹³ of decays) over a 70-meter distance from the source to the detector. This challenging task necessitates a sophisticated magnetic field configuration to ensure adiabatic transmission of these electrons. The problem addressed is the design, implementation, and validation of a complex chain of superconducting magnets that can provide the required magnetic flux and stability for this sensitive measurement.

Methods

The KATRIN experiment utilizes a chain of ten single superconducting solenoid magnets and two large superconducting magnet systems (WGTS and CPS) to create a guiding magnetic field. These magnets are designed to provide an invariant magnetic flux of 191 Tcm². Key design considerations include:

  • Magnetic Flux Density: Achieving high magnetic flux density (up to 6 T) at specific points (source and pinch magnet) for high energy resolution and to restrict the acceptance angle.
  • Field Stability: Ensuring high magnetic field stability (better than 0.01%/month for source magnets) to minimize systematic uncertainties.
  • Homogeneity: Maintaining field homogeneity over long sections to prevent electron trapping.
  • Magnet Safety Systems (MSS): Developing robust safety systems, including quench detection and external dumping units, to protect the magnets from failures like quenches, cooling loss, or power outages.
  • Operation Modes: Employing both driven mode (DM) and persistent current mode (PM) for different magnet systems, with a focus on DM for large systems due to stability and reliability concerns.
  • Instrumentation: Utilizing Hall probes, DCCTs, NMR probes, and fluxgate sensors for precise monitoring of magnetic field stability and current.

Datasets

Not discussed in the paper. The paper focuses on the design and performance of the magnet systems themselves, with experimental data from commissioning runs used for validation.

Key Insights and Ideas

  • Complexity of Large-Scale Superconducting Systems: Manufacturing and integrating a long chain of superconducting magnets with precise alignment requirements is a significant engineering feat.
  • Trade-offs in Magnet Design: The design involves balancing requirements for magnetic field strength, homogeneity, stability, and safety, often leading to complex coil configurations and operational modes.
  • Importance of Magnet Safety: Robust magnet safety systems are critical, especially for large superconducting magnets, to prevent catastrophic failures and ensure continuous operation. The development of distinct quench detection for inductively coupled magnets is a notable advancement.
  • Operational Flexibility: The ability to switch between driven and persistent current modes provides flexibility in operation and addresses specific challenges like persistent switch stability.
  • Validation through Commissioning: Early commissioning runs with electron sources and radioactive krypton gas were crucial for validating the magnet alignment, transport capabilities, and field stability under realistic conditions.

Key Results

  • Successful Operation: The KATRIN superconducting magnet chain was successfully operated for several weeks at 70% of the design fields during commissioning runs.
  • Field Stability: The magnetic field stability of the source magnets was demonstrated to be better than 0.01% per month at 70% of the design fields.
  • Electron Transport: The first beam tests successfully demonstrated the transport of electrons through the entire 70-m-long beam line, confirming the proper alignment and guiding capabilities of the magnet system.
  • Magnet Safety System Performance: The magnet safety systems were successfully tested and commissioned, demonstrating their ability to detect and manage magnet failures.
  • Design Parameters Met: The magnets were designed, constructed, and installed meeting stringent specifications for magnetic flux, field strength, and stability.

Limitations and Future Work

  • Nominal Field Reduction: The experiment is currently operating at 70% of the design magnetic fields to ensure safe operation without the risk of quenches. Future work will involve re-evaluating and potentially increasing the magnetic flux density to its full design value.
  • Tritium Operation: The full KATRIN experiment, including tritium operation, is scheduled for 2018. The current results are based on electron sources and krypton gas.
  • Long-Term Stability: While initial stability tests are promising, continuous monitoring and re-evaluation of field stability will be necessary during long-term operation.
  • Further Beam Alignment: Beam alignment will be re-checked more precisely with mono-energetic and angular-selective electron sources.

Summary updated

Abstract

International audience
BibTeX
@article{arenz2018katrin,
  author = {M. Arenz and Woo-Jeong Baek and M. Beck and A. Beglarian and J. Behrens and Thaisa Storchi‐Bergmann and A. I. Berlëv and U. Besserer and K. Blaum and T. Bode and B. Bornschein and L. Bornschein and T. Brunst and N. Buzinsky and S. Chilingaryan and W. Choi and M. Deffert and P. J. Doe and O. Dragoun and G. Drexlin and S. Dyba and F. Edzards and K. Eitel and E. Ellinger and R. Engel and S. Enomoto and M. Erhard and D. Eversheim and M. Fedkevych and J. A. Formaggio and F. M. Fränkle and G. Franklin and F. Friedel and A. Fulst and W. Gil and F. Glück and A. González Ureña and S. Grohmann and Robin Größle and R. Gumbsheimer and M. Hackenjos and V. Hannen and F. Harms and N. Haußmann and F. Heizmann and K. Helbing and Werner Herz and S. Hickford and D. Hilk and M. A. Howe and A. Huber and A. Jansen and J. Kellerer and N. Kernert and L. Kippenbrock and M. Kleesiek and Manuel Klein and A. Kopmann and M. Korzeczek and A. Kovalík and B. Krasch and M. Kraus and L. Kuckert and T. Lasserre and O. Lebeda and J. Letnev and Alexey Lokhov and M. Machatschek and A. Marsteller and E. L. Martín and S. Mertens and S. Mirz and B. Monreal and H. Neumann and S. Niemes and A. Off and A. Osipowicz and E. Otten and D. S. Parno and A. Pollithy and A. W. P. Poon and F. Priester and P. C.-O. Ranitzsch and O. Rest and R. G. H. Robertson and Federico Roccati and C. Rodenbeck and M. Röllig and C. Röttele and M. Ryšavý and R. Sack and Alejandro Sáenz and L. Schimpf and K. Schlösser and Magnus Schlösser and K. Schönung and M. Schrank and Hendrik Seitz-Moskaliuk and J. Sentkerestiová and V. V. Sinev},
  title = {{The KATRIN superconducting magnets: overview and first performance results}},
  journal = {Journal of Instrumentation},
  year = {2018},
  doi = {10.1088/1748-0221/13/08/t08005},
}

Loading related content...