The Jülich Experience With Simultaneous 3T MR-BrainPET: Methods and Technology

Liliana Caldeira, Elena Rota Kops, Seong Dae Yun, Nuno Silva, Jörg Mauler, Christoph Weirich, J. Scheins, Hans Herzog, Lutz Tellmann, Philipp Lohmann, Karl‐Josef Langen, Christoph Lerche, N. Jon ShahIEEE Transactions on Radiation and Plasma Medical Sciences 2018 · DOI

Abstract

Building on the success of positron emission tomography (PET)/CT scanners, a hybrid imaging technology, combining PET with the versatile attributes of magnetic resonance imaging (MRI), has been in use for over ten years. At the Forschungszentrum Jülich, one of the four prototypes available worldwide, combining a commercial 3T MRI with a newly developed BrainPET insert, was installed in 2008, allowing simultaneous data acquisition with PET and MRI. Here, we report on our ten-year-long experience of the methods and technology developed through this paper with numerous patients and volunteers. In the course of our research, a number of different radiotracers, such as [ <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">18</sup> F]Fluoroethyltyrosine, [ <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">11</sup> C]Flumazenil, [ <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">11</sup> C]Raclopride, and [ <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">15</sup> O]H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> O, have been applied while simultaneously measuring several different MR sequences. The PET data obtained with the BrainPET has demonstrated higher image quality and superior resolution capability compared to the stand-alone PET scanner, ECAT Exact HR+. Furthermore, the simultaneous acquisition of MR images alongside BrainPET scans, using different sequences, showed an excellent quality without any relevant artifacts and provided useful complementary information. Our experiences with the hybrid 3T MR-BrainPET indicate a promising basis for further developments of this unique technique, allowing simultaneous brain imaging in a clinical setting.
BibTeX
@article{caldeira2018julich,
  author = {Liliana Caldeira and Elena Rota Kops and Seong Dae Yun and Nuno Silva and Jörg Mauler and Christoph Weirich and J. Scheins and Hans Herzog and Lutz Tellmann and Philipp Lohmann and Karl‐Josef Langen and Christoph Lerche and N. Jon Shah},
  title = {{The Jülich Experience With Simultaneous 3T MR-BrainPET: Methods and Technology}},
  journal = {IEEE Transactions on Radiation and Plasma Medical Sciences},
  year = {2018},
  doi = {10.1109/trpms.2018.2863953},
}

Loading related content...

Figure