Abstract: The Wide Field Imager (WFI) is one of the two scientific instruments proposed for the Athena+ X-ray observatory. It will provide imaging in the 0.1-15 keV band over a wide field, simultaneously with spectrally and time-resolved photon counting. The instrument is designed to make optimal use of the grasp (collecting area times solid angle product) provided by the optical design of the Athena+ mirror system, by combining a sensitive approx. 40' diameter field of view DEPFET detector with a pixel size properly sampling the angular resolution of 5 arc sec on-axis. This synthesis makes the WFI a very powerful survey instrument, significantly surpassing currently existing capabilities. In addition, the WFI will provide unprecedented simultaneous high-time resolution and high count rate capabilities for the observation of bright sources with low pile-up and high efficiency.
Introduction: Addressing the "Grasp" Gap
To understand the formation of large-scale structures and the growth of supermassive black holes, astronomers require X-ray observations with significantly higher "grasp"—the product of collecting area and field of view. Current observatories like Chandra and XMM-Newton face a trade-off between high angular resolution over small fields and susceptibility to "pile-up" (where multiple photons strike the same pixel during one exposure) when observing bright sources. Additionally, standard CCDs are vulnerable to radiation damage that degrades performance over time. The Wide Field Imager (WFI) for Athena+ addresses these challenges using advanced DEPFET sensor technology.
Instrument Design and Methodology
The core of the WFI is the DEPFET (DEpleted P-channel Field Effect Transistor) active pixel sensor. Unlike traditional CCDs that shift charge across the chip to a readout node, each DEPFET pixel integrates the detector and the first stage of amplification.
The DEPFET Active Pixel Sensor
In a DEPFET pixel, incident X-rays generate electron-hole pairs within a 450 µm thick silicon bulk. The electrons are collected in an "internal gate" located directly beneath the transistor channel. The presence of this charge modulates the transistor's conductivity, allowing the energy of the photon to be measured in place. This architecture is inherently radiation-hard because it avoids the Charge Transfer Inefficiency (CTI) issues common in CCDs.
Innovation: The Gateable Shutter
A key innovation for the WFI is the "gateable" DEPFET. By incorporating a specific implantation, researchers created a fast internal shutter. This allows the sensor to "ignore" photons hitting the pixel during the readout phase, virtually eliminating "out-of-time" events that cause spectral distortion in traditional sensors.
Focal Plane and Readout
The WFI uses a mosaic of chips to cover a wide field of view (baseline 40’ x 40’). A specialized central chip (256x256 pixels) is optimized for high-speed timing of bright sources, while four larger outer chips provide wide-field coverage. By utilizing a "drain-readout" mode, the system achieves a readout time of just 2 µs per row, enabling high-speed observations with minimal data loss.
Key Performance and Results
Laboratory calibration and simulations confirm the WFI's superior performance:
- Energy Range: 0.1 to 15 keV.
- Spectral Resolution: 125 eV (FWHM) at 5.9 keV, reaching the theoretical Fano limit for silicon.
- Throughput: Capable of handling sources as bright as 1 Crab with >80% throughput and <5% pile-up.
- Effective Area: Approximately 1.7 m² at 1 keV, a tenfold improvement over previous missions.
Challenges and Future Work
While the underlying technology is mature, the transition to the larger Athena+ mission scale introduces engineering hurdles. The physical size of the required optical blocking filters has nearly doubled, requiring careful design to ensure stability during launch. Future work will focus on optimizing the focal plane layout by folding electronics to the backside of the central chip and finalizing the mechanical assembly of the filter wheel.
Summary updated