NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

The Heterogeneous Effect of High PEEP strategies on Survival in Acute Respiratory Distress Syndrome: preliminary results of a data-driven analysis of randomized trials

Jasper V. Smit, Jesse H. Krijthe, Jasper van Bommel, Demet Sulemanji, Jesús Villar, Fernando Suárez-Sipmann, Rosa L. Fernández, Fernando G. Zampieri, Israel Silva Maia, Alexandre Biasi Cavalcanti, Matthias Briel, M Meade, Qi Zhou, Roy G. Brower, Parul Sinha, Benjamin Bartek, C.s. Calfee, Alain Mercat, Jean‐Christophe Richard, L. Brochard, A. Serpa Neto, Carol S. Hodgson, Elias Baedorf Kassis, Daniel Talmor, Diederik Gommers, Michel E. van Genderen, Marcel Reinders, Annemijn H. Jonkman2025

Introduction

Acute Respiratory Distress Syndrome (ARDS) remains a primary cause of mortality in intensive care units worldwide. While Positive End-Expiratory Pressure (PEEP) is a cornerstone of mechanical ventilation, the optimal level—high versus low—has been a subject of intense clinical debate for decades. Large-scale randomized controlled trials (RCTs) have yielded conflicting results, suggesting that while some patients benefit from higher pressures, others may suffer harm from lung over-distension.

This study addresses the "one-size-fits-all" limitation by investigating the Heterogeneity of Treatment Effect (HTE). By applying advanced machine learning to individual patient data (IPD), the researchers aim to identify specific patient characteristics that predict a positive response to high PEEP strategies.

Methodology: A Predictive Framework

The researchers utilized an explorative predictive HTE analysis, leveraging IPD from three major trials: ALVEOLI, LOVS, and EXPRESS (n=2,299). A key innovation in their approach was the stratification of patients into three tertiles based on their baseline PEEP levels (≤8, 9–11, and ≥12 cmH2O). This stratification accounts for the fact that respiratory variables are dynamic and change depending on the pressure at which they are measured.

The study employed a robust machine learning ensemble, testing 10 candidate methods including:

  • Meta-learners: S, T, X, and R-learners using both Lasso and LightGBM base models.
  • Causal Forests: A method specifically designed to estimate treatment effects in high-dimensional data.

To ensure the models were not overfitted to specific trial protocols, the team used "leave-one-trial-out" cross-validation (LOTO-CV). Performance was measured using "AUC-benefit," a metric that evaluates a model's ability to distinguish between treatment responders and non-responders.

Key Findings: Compliance and Oxygenation

The preliminary results highlight two primary physiological markers as critical modifiers of the PEEP effect:

1. Respiratory System Compliance ($C_{RS}$)

In the high baseline PEEP tertile (≥12 cmH2O), respiratory system compliance emerged as a decisive factor. The models identified a threshold of 26.5 mL/cmH2O. Patients with a $C_{RS}$ above this value were predicted to benefit from high PEEP, while those below it were predicted to experience harm. This suggests that the lung's "stretchability" at baseline is a vital indicator of whether it can tolerate additional pressure.

2. Oxygenation ($PaO_2/FiO_2$ Ratio)

The study re-evaluated the "Briel hypothesis," which posits that patients with more severe ARDS (lower $PaO_2/FiO_2$) benefit more from high PEEP. The findings confirmed this, but with a crucial caveat: the predictive power was strongest when oxygenation was measured at low baseline PEEP (≤8 cmH2O). In this group, a $PaO_2/FiO_2 \le 200$ mmHg predicted benefit (OR 0.80), whereas a ratio $> 200$ mmHg was associated with significantly increased mortality risk (OR 1.74).

Challenging the Inflammatory Subphenotype

Recent ARDS research has focused on "hyperinflammatory" versus "hypoinflammatory" subphenotypes. While previous analyses of the ALVEOLI trial suggested hyperinflammatory patients benefit more from high PEEP, this study could not replicate that finding using data from the LOVS trial. This discrepancy underscores the complexity of ARDS and suggests that inflammatory markers may not be universal predictors of PEEP response across different clinical settings.

Conclusion and Future Validation

This manuscript serves as a pre-registration for the external validation of these models. The researchers have "frozen" their trained models before applying them to a separate test cohort of 1,404 patients from five additional trials (ART, EPVENT, PHARLAP 2011 & 2019, and Kacmarek et al.).

By moving beyond average treatment effects, this work paves the way for precision medicine in the ICU. If validated, these thresholds—specifically the 26.5 mL/cmH2O compliance mark—could provide clinicians with a data-driven tool to tailor ventilator settings to the individual needs of ARDS patients, potentially improving survival rates in this critical population.

Summary updated

BibTeX
@misc{smit2025heterogeneous,
  author = {Jasper V. Smit and Jesse H. Krijthe and Jasper van Bommel and Demet Sulemanji and Jesús Villar and Fernando Suárez-Sipmann and Rosa L. Fernández and Fernando G. Zampieri and Israel Silva Maia and Alexandre Biasi Cavalcanti and Matthias Briel and M Meade and Qi Zhou and Roy G. Brower and Parul Sinha and Benjamin Bartek and C.S. Calfee and Alain Mercat and Jean‐Christophe Richard and L. Brochard and A. Serpa Neto and Carol S. Hodgson and Elias Baedorf Kassis and Daniel Talmor and Diederik Gommers and Michel E. van Genderen and Marcel Reinders and Annemijn H. Jonkman},