The Effect of Hearing Aid Amplification on Gait Parameters: A Pilot Study Using Ear-Worn Motion Sensors

Ann-Kristin Seifer, Arne Küderle, Kaja Strobel, Ronny Hannemann, Bjoern M. EskofierAudiology 2025 · DOI

TL;DR

This study investigated how hearing aid amplification affects gait in individuals with hearing loss, using novel ear-worn sensors. They found that in low-cognitive-demand settings, hearing aids didn't significantly alter gait parameters, but the ear-worn system proved highly accurate for mobility assessment.

What Problem Does This Paper Address?

Hearing loss, especially in older adults, is linked to poorer physical function, increased fall risk, and altered gait patterns like slower walking and shorter steps. One theory is that the extra cognitive effort required to process sound with hearing loss diverts resources from motor control. While hearing aids are known to improve balance, their direct impact on gait, particularly in complex, real-world scenarios, remains less understood. This paper aims to bridge this gap by examining gait changes with and without hearing aid amplification under dual-task conditions, while also validating the use of ear-worn sensors for this type of analysis.

Methods

The researchers employed a pilot study with 25 participants who had mild to severe bilateral hearing loss. They used hearing aids equipped with integrated accelerometers and a custom open-source gait analysis pipeline called "EarGait." Participants walked under various conditions: a baseline single-task walk, and two dual-task scenarios (walking while performing arithmetic or listening to words). Crucially, they compared gait parameters with hearing aids both ON (amplification enabled) and OFF (amplification disabled, but the device still worn for sensor data collection). To further validate their ear-worn system, they also used foot-worn inertial measurement units (IMUs) as a reference. Statistical analysis involved repeated-measures ANOVAs to compare gait parameters across conditions.

Datasets

Not discussed in the paper. The study used data collected from participants during controlled laboratory experiments.

Key Insights and Ideas

  • Dual-task costs (DTCs) were surprisingly low: The researchers expected higher DTCs, indicating significant cognitive load, especially in the listening dual-task. The low DTCs suggest their dual-task paradigm might not have imposed enough cognitive demand to reveal the hypothesized effects of hearing aids on gait.
  • Ear-worn sensors are highly promising for mobility assessment: The study demonstrated that ear-worn accelerometers, integrated into hearing aids, can accurately measure gait parameters, performing comparably to traditional foot-worn sensors. This opens doors for unobtrusive, continuous monitoring.
  • Hearing aid amplification's impact on gait is context-dependent: In simple, low-cognitive-demand walking scenarios, hearing aids didn't significantly alter gait. This implies that any benefits or detriments might only manifest under more challenging, real-world conditions.

Key Results

  • No significant differences in gait velocity or step length were found between walking with hearing aids ON versus OFF.
  • A significant interaction effect was observed for stride time, but the effect size was negligible, meaning the practical impact was minimal.
  • Speech intelligibility significantly improved with hearing aids ON, by approximately 23% when sitting and 17% when walking, confirming the devices' primary function.
  • The ear-worn gait analysis system showed strong performance, with errors comparable to previous validation studies and high correlation (r=0.99 for stride time) with foot-worn sensors.

Limitations and Future Work

The authors acknowledge that the dual-task paradigm may not have imposed sufficient cognitive demand, limiting conclusions about hearing aid effects in complex, cognitively demanding situations. They also note that this was a pilot study with a small sample size (25 participants), limiting generalizability.

Future work should focus on:

  • Exploring more complex, ecologically valid real-world conditions to better understand the impact of hearing aids on walking behavior.
  • Developing standardized acoustic dual-task paradigms to enable more meaningful cross-study comparisons.
  • Investigating the underlying mechanisms of hearing loss-related gait changes in complex environments.
  • Leveraging ear-worn sensors for continuous, unobtrusive gait monitoring in everyday settings, potentially aiding in fall risk detection and adaptive auditory interventions.

Summary updated

Abstract

<b>Background/Objectives</b>: Hearing loss, particularly in older adults, is associated with reduced physical functioning; increased fall risk; and altered gait patterns, including slower walking speed and shorter step length. While the underlying mechanisms are not fully understood, one possibility is that these gait changes result from an additional cognitive load due to hearing difficulties. Prior research suggests that hearing aids may improve balance; however, their impact on gait remains less well explored. <b>Methods</b>: This study investigated gait parameters in individuals with hearing loss as they walked with and without hearing aid amplification under different dual-task conditions. Additionally, we showed the potential of ear-worn sensors for detecting relevant gait changes. To achieve this, we used a hearing-aid-integrated accelerometer and our open-source EarGait framework comprising gait-related algorithms specifically developed for ear-worn sensors. <b>Results</b>: Our findings revealed no significant differences in gait velocity or step length between the unaided and aided conditions. For stride time, we observed a significant interaction effect; however, the effect size was negligible. The dual-task costs were lower than in previous reports, indicating that the applied dual-task paradigm did not induce the expected cognitive demand. The ear-worn gait analysis system showed strong performance compared to foot-worn sensors. <b>Conclusions</b>: Our findings indicate that in controlled, low-cognitive-demand settings, hearing aid amplification does not affect gait performance and, therefore, neither hinders nor improves walking performance. Additionally, the high accuracy of the ear-worn gait analysis system highlights the strong potential of ear-mounted wearable devices ("earables") for real-world mobility assessments. Future research should explore more complex real-world conditions to better understand the impact of hearing aids on walking behavior. Our proposed earable-based system offers a promising tool for continuous, unobtrusive gait monitoring in everyday environments.
BibTeX
@inproceedings{seifer2025effect,
  author = {Ann-Kristin Seifer and Arne Küderle and Kaja Strobel and Ronny Hannemann and Bjoern M. Eskofier},
  title = {{The Effect of Hearing Aid Amplification on Gait Parameters: A Pilot Study Using Ear-Worn Motion Sensors}},
  booktitle = {Audiology},