The Development of Controllable Magnetic Driven Microphysiological System

Jia‐Wei Yang, Yuwei Chen, Pei-Yi Ho, Liane Jiang, Kuan Yu Hsieh, Sheng-Jen Cheng, Ko-Chih Lin, Huai-En Lu, Hsien‐Yi Chiu, Shien‐Fong Lin, Guan‐Yu ChenFrontiers in Cell and Developmental Biology 2019 · DOI

TL;DR

Researchers have developed a novel, magnetically driven microphysiological system for culturing alveolar cells. This system simplifies complex fluid control mechanisms, enabling more stable, long-term cell culture and better recapitulation of in vitro lung tissue functions, which is crucial for disease modeling and drug screening.

What Problem Does This Paper Address?

Creating accurate in vitro models of human lung alveoli for studying diseases and testing treatments has been challenging. Existing microphysiological systems often rely on complex external pumps and tubing, making them cumbersome and prone to external interference. Furthermore, maintaining the long-term function and differentiation of primary alveolar cells in these systems has been difficult, limiting their representativeness of actual lung tissue. This paper aims to address these limitations by developing a simpler, more controllable, and dynamic microfluidic system for alveolar cell culture.

Methods

The core innovation is a magnetically driven microfluidic chip. The system consists of a three-layer polydimethylsiloxane (PDMS)-based chip with a microchannel for cell culture, bonded to a glass slide. A key component is a magnetic film integrated into the chip. This film is actuated by an external electromagnet controlled by an Arduino microcontroller. By varying the magnetic field strength, the researchers can precisely control the deformation of the magnetic film, which in turn drives fluid circulation within the microchannel. This eliminates the need for external pumps and complex tubing. The system also incorporates a custom-designed support bracket for precise positioning of the electromagnet over the chip.

Datasets

Not discussed in the paper. The study primarily uses experimental data generated from the developed microfluidic system and cell cultures.

Key Insights and Ideas

  • Simplified Fluid Control: The magnetic drive system offers a significant advantage by eliminating the need for external pumps and tubing, leading to a simpler and more robust microfluidic setup.
  • Controllable Dynamic Flow: The ability to precisely control fluid flow patterns (sinusoidal, stepped sinusoidal) and rates using magnetic force opens up new possibilities for mimicking physiological conditions and optimizing cell culture.
  • Enhanced Cell Viability and Function: The dynamic culture environment provided by the system promotes uniform cell attachment, long-term culture, and maintenance of cell structure and differentiation functions, as evidenced by the successful culture of human alveolar epithelial cells (HPAEpiCs).
  • Improved In Vitro Modeling: The system's ability to recapitulate aspects of the dynamic in vivo environment allows for more relevant responses to stimuli, such as silica nanoparticles, compared to static culture conditions.

Key Results

  • The magnetic film deformation could be precisely controlled, reaching up to 203.49 µm with a magnetic force of 69.84 mT.
  • The system demonstrated stable, leak-free fluid flow for extended periods, even with two different colored dyes.
  • Programmable control of flow rates was achieved, with volumetric flow rates ranging from 18.18 µL/min down to 3.88 µL/min by adjusting the magnetic field.
  • HPAEpiCs cultured in the dynamic system showed better cell viability and maintained barrier function (ZO-1) and surfactant protein C (pro-SPC) secretion compared to static cultures, especially when exposed to silica nanoparticles.
  • Inflammatory responses (IL-6 release) to silica nanoparticles were significantly lower in the dynamic system compared to static conditions.
  • Fewer blue fluorescent particles adhered to cells in the dynamic environment, indicating reduced particle uptake and potentially lower cytotoxicity.

Limitations and Future Work

  • Individualized Breathing Simulation: While the paper mentions the potential to simulate breathing signals, the current study focuses on fluid flow control. Future work could explore integrating more complex physiological simulations, such as breathing mechanics.
  • Complex Tissue Models: The current study focuses on alveolar epithelial cells. Expanding the system to incorporate other cell types (e.g., endothelial cells, immune cells) to create more complex multi-cellular lung models is a logical next step.
  • Wireless Connectivity: The paper briefly mentions a wireless connection system for collecting breathing signals. Further development in this area could enhance the system's utility for long-term monitoring and personalized medicine applications.
  • Standardization and Scalability: While the system simplifies construction, further work may be needed to standardize fabrication and ensure scalability for high-throughput screening applications.

Summary updated

Abstract

Current research has enabled the use of microphysiological systems and creation of models for alveolar and pulmonary diseases. However, bottlenecks remain in terms of medium- and long-term regulation of cell cultures and their functions in microchannel systems, as well as in the enhancement of <i>in vitro</i> representation of alveolar models and reference values of the data. Currently used systems also require on-chip manufacturing of complex units, such as pumps, tubes, and other cumbersome structures for maintaining cells in culture. In addition, system simplification and minimization of all external and human factors major challenges facing the establishment of <i>in vitro</i> alveolar models. In this study, a magnetically driven dynamic alveolus cell-culture system has been developed to use controlled magnetic force to drive a magnetic film on the chip, thereby directing the fluid within it to produce a circulating flow. The system has been confirmed to be conducive with regard to facilitating uniform attachment of human alveolar epithelial cells and long-term culture. The cell structure has been recapitulated, and differentiation functions have been maintained. Subsequently, reactions between silica nanoparticles and human alveolar epithelial cells have been used to validate the effects and advantages of the proposed dynamic chip-based system compared to a static environment. The innovative concept of use of a magnetic drive has been successfully employed in this study to create a simple and controllable yet dynamic alveolus cell-culture system to realize its functions and advantages with regard to <i>in vitro</i> tissue construction.
BibTeX
@inproceedings{yang2019development,
  author = {Jia‐Wei Yang and Yuwei Chen and Pei-Yi Ho and Liane Jiang and Kuan Yu Hsieh and Sheng-Jen Cheng and Ko-Chih Lin and Huai-En Lu and Hsien‐Yi Chiu and Shien‐Fong Lin and Guan‐Yu Chen},
  title = {{The Development of Controllable Magnetic Driven Microphysiological System}},
  booktitle = {Frontiers in Cell and Developmental Biology},
  year = {2019},
  doi = {10.3389/fcell.2019.00275},
}

Loading related content...

Figure