Testing technology for off-axis parabolic mirror during fine grinding stage
Abstract
A method to test an off-axis parabolic (OAP) mirror at fine grinding stage using CMM (coordinate measuring machine) is introduced in this paper. Tilt error and the probe radius error have been removed as a system error before interpolation. An interpolation method, which based on Tikhonov regularization, is used to fit surface error. An example, which shows the effectiveness of this method, is also given.
BibTeX
@inproceedings{yu2010testing,
author = {Han Yu and Wu Fan and Yongjian Wan},
title = {{Testing technology for off-axis parabolic mirror during fine grinding stage}},
booktitle = {Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE},
year = {2010},
doi = {10.1117/12.867715},
}Ask Althea to put this paper to the test.