Abstract
The precision measurement of real-time electron temporal profiles is crucial for advancing electron and X-ray devices used in ultrafast imaging and spectroscopy. While high temporal resolution and large temporal window can be achieved separately using different technologies, real-time measurement enabling simultaneous high resolution and large window remains challenging. Here, we present the first THz-driven sampling electron oscilloscope capable of measuring electron pulses with high temporal resolution and a scalable, large temporal window simultaneously. The transient THz electric field induces temporal electron streaking in the vertical axis, while extended interaction along the horizontal axis leads to a propagation-induced time delay, enabling electron beam sampling with sub-cycle THz wave. This allows real-time femtosecond electron measurement with a tens-of-picosecond window, surpassing previous THz-based techniques by an order of magnitude. The measurement capability is further enhanced through projection imaging, deflection cavity tilting, and shorted antenna utilization, resulting in signal spatial magnification, extended temporal window, and increased field strength. The technique holds promise for a wide range of applications and opens new opportunities in ultrafast science and accelerator technologies.
Introduction
In ultrafast science, electron pulses serve as the "shutter" for filming atomic-scale dynamics. Characterizing the temporal profile of these pulses is essential for interpreting experimental results. However, existing technologies force a compromise: radio-frequency (RF) cavities provide a wide temporal window (tens of picoseconds) but are limited by phase jitter to tens of femtoseconds in resolution. Conversely, all-optical methods using near-infrared (NIR) lasers offer attosecond resolution but possess extremely narrow measurement windows. This paper introduces a terahertz (THz)-driven architecture that bridges this gap, achieving femtosecond resolution over a tens-of-picoseconds range in real-time.
The THz-Driven Sampling Electron Oscilloscope
The core of the system is a two-dimensional mapping scheme utilizing a specially designed Vivaldi antenna. This exponentially shaped antenna couples and focuses THz waves into a 100 µm slit, achieving an 18-fold field enhancement.
2D Mapping Logic
The device maps temporal information onto two spatial dimensions:
- Vertical Axis (y): The THz electric field streaks the electrons, converting their arrival time into a vertical position. This provides the high-resolution timing information.
- Horizontal Axis (x): As the THz wave propagates across the slit, different horizontal segments of the electron beam interact with the wave at different times. This "propagation-induced delay" transforms the horizontal axis into a sampling window.
Enhancement Techniques
To further improve performance, several techniques were implemented:
- Cavity Tilting: By tilting the antenna at an angle $\theta$, the interaction length is effectively increased, scaling the temporal window up to 40 ps.
- Shorted Antenna: Reflecting the THz wave creates a superposition of fields, resulting in record-breaking streaking gradients of 200 µrad/fs.
- Projection Imaging: Magnetic lenses magnify the signal on the detector by a factor of 20, ensuring high effective resolution.
Key Results and Insights
The experimental setup demonstrated a resolution of approximately 9 femtoseconds within a temporal window of up to 40 picoseconds. The Vivaldi antenna provided a field gradient of 250 MV/m, significantly higher than standard slit-based designs. Furthermore, the system exhibited high stability, with a timing jitter of only 3 femtoseconds (rms) over an hour.
The "Aha!" moment of this research is the use of the electron beam's spatial width to sample time. By spreading the interaction across the horizontal axis, a spatial dimension is effectively converted into a multi-picosecond timeline.
Discussion and Future Outlook
While the current design significantly advances the state-of-the-art, a trade-off remains: tilting the cavity to extend the window eventually degrades temporal resolution due to increased "time-per-pixel." Additionally, wider beams required for larger windows may suffer from lower signal-to-noise ratios. Future work will focus on minimizing the initial vertical beam size to push the device into the sub-femtosecond resolution regime, opening new frontiers in ultrafast imaging and accelerator physics.
Summary updated