Temporal resolution of x-ray detector for pulsar navigation
Abstract
Pulsar navigation is a promising new technique for space exploration because of its autonomous and deep space capability. Since the baseline of pulsar navigation approach is to observe the X rays (0.2~20keV) emitted from pulsars, a compact high temporal resolution X-ray detector is needed. In this paper an micro-channel plate(MCP) photon counting detector sensitive to X-rays is proposed. The detection system consists of a CsI photocathode, a 50mm diameter micro-channel plate (MCP) stack, a collection anode, a preamplifier, a constant fraction discriminator(CFD) and data acquisition(DAQ). The incident X-rays photons are absorbed by CsI and converted to photoelectrons, the electrons are multiplied by MCP and collected by the anode. Anode output signal is a fast pulse which need to be amplified by preamplifier and then fed to CFD circuit and DAQ for a precise timing. The total temporal resolution (ΔT) of the entire detection system could be determined by ▵tD, the intrinsic temporal resolution of cathode-MCP-anode, and ▵E the resolution of electronic system including preamplifier and CFD. The resolution of the detection system is tested to be 18.4ns in experiment.
BibTeX
@inproceedings{sheng2011temporal,
author = {Lizhi Sheng and Baosheng Zhao and Huijun Hu and Peng Wang and Qiurong Yan and Chen Baomei and Yongan Liu and Xiaoping Ouyang and Ding Chen},
title = {{Temporal resolution of x-ray detector for pulsar navigation}},
booktitle = {Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE},
year = {2011},
doi = {10.1117/12.900678},