Temperature field measurement and analysis about boiler reheater vent-pipe and evacuating water pipe

Liang ZhangEnergy 2001

Abstract

In order to research thermal fatigue of corner welding line of the 125MW dynamotor boiler reheater, the pipe wall's temperature has been measured for a 420t/h boiler reheater collecting steam box and evacuating water pipe. It is been proved under various working condition, the welding line suffer frequent thermal stress so as to produce crack there. This text give step of guard against crack above the temperature measure.