NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

T-Net: Encoder-Decoder in Encoder-Decoder architecture for the main vessel segmentation in coronary angiography

Tae Joon Jun, Jihoon Kweon, Young-Hak Kim, Daeyoung KimarXiv 2019 · DOI

TL;DR

This paper introduces T-Net, a novel encoder-decoder architecture designed to improve medical image segmentation, specifically for main coronary vessels. By incorporating a nested encoder-decoder structure (EDiED), T-Net allows for more versatile feature fusion between encoder and decoder stages, overcoming limitations of the standard U-Net and leading to more accurate vessel segmentation.

What Problem Does This Paper Address?

The paper tackles the challenge of accurately segmenting main blood vessels in coronary angiography images. Existing methods, particularly the widely used U-Net, face limitations due to their fixed, symmetric encoder-decoder structure. This symmetry results in a single connection point between encoder and decoder feature maps, potentially hindering the effective transfer of both low-level (e.g., vessel shape) and high-level (e.g., vessel identity) features to the decoder for precise mask generation. This is especially problematic in medical imaging where subtle details and accurate boundary delineation are crucial.

Methods

The core innovation is the T-Net architecture, which features an Encoder-Decoder in Encoder-Decoder (EDiED) structure. Unlike U-Net's single concatenate layer, T-Net introduces multiple, varied-size connections between encoder and decoder blocks. This is achieved by strategically applying pooling and up-sampling operations within both the encoder and decoder stages, creating feature maps of different resolutions. These multiple connections allow for a richer transfer of features from all levels of the encoder to the decoder, enabling more accurate mask prediction from earlier decoder stages. The paper also explores various configurations of T-Net (e.g., T3-Net, T5-Net, T53-Net) based on the number and order of pooling and up-sampling operations. An optimized T-Net (Opt-Net) is further developed, incorporating fine-tuning strategies like short-cut connections and specific loss functions.

Datasets

The study utilizes a dataset of 4,700 grayscale coronary angiography images, each with a size of 512x512 pixels. These images were collected from patients at Asan Medical Center. The dataset was split into training (80%), testing (20%), and validation sets. The main vessels segmented are the Left Anterior Descending artery (LAD), Left Circumflex artery (LCX), and Right Coronary artery (RCA).

Key Insights and Ideas

  • EDiED for richer feature fusion: The nested encoder-decoder structure is key. By allowing connections at multiple resolutions and stages, T-Net can leverage a broader spectrum of features from the encoder, leading to better segmentation.
  • Breaking U-Net's symmetry: The paper highlights how U-Net's symmetric connections can be a bottleneck. T-Net's asymmetric and multi-level connections offer a more flexible and effective way to transfer information.
  • Early mask prediction: T-Net's architecture allows for clearer mask prediction to begin earlier in the decoder stages, suggesting a more robust understanding of the vessel structure.
  • Short-cut connections matter: The optimized T-Net (Opt-Net) demonstrates that incorporating short-cut connections significantly improves performance, highlighting their importance in deep network design.

Key Results

  • Improved DSC: Under the same conditions, T-Net achieved a Dice Similarity Coefficient (DSC) of 0.815, which is 0.095 higher than U-Net's 0.720.
  • Optimized T-Net performance: The optimized T-Net (Opt-Net) achieved an even higher DSC of 0.890, a significant 0.170 improvement over U-Net.
  • Vessel-specific performance: T-Net showed particular strength in segmenting the LCX artery, which was identified as the most difficult vessel to segment. Opt-Net achieved a DSC of 0.860 for LCX, a substantial improvement over U-Net's 0.565. RCA segmentation was the easiest, with Opt-Net achieving a DSC of 0.927.
  • Visualizations: Weight activation visualizations confirmed that T-Net models predict masks more accurately from earlier decoder stages compared to U-Net.

Limitations and Future Work

  • 2D focus: The current work focuses on 2D T-Net. The authors suggest that extending this to a 3D T-Net structure for 3D medical image segmentation is a promising future direction.
  • Computational cost: While T-Net shows improved performance, the paper notes that the optimized T-Net has a higher number of free parameters than U-Net, implying potential computational trade-offs.
  • Dataset size: The authors acknowledge that their dataset of 4,700 images is relatively small compared to general datasets, though they argue that the specific nature of coronary angiography images helps mitigate overfitting with proper augmentation.
  • Further optimization: While Opt-Net represents an optimized version, the paper suggests that further improvements could be achieved by increasing the reduction factor of the learning rate and lengthening the patience epoch for longer training.

Summary updated

BibTeX
@misc{jun2019t,
  author = {Tae Joon Jun and Jihoon Kweon and Young-Hak Kim and Daeyoung Kim},
  title = {{T-Net: Encoder-Decoder in Encoder-Decoder architecture for the main vessel segmentation in coronary angiography}},
  year = {2019},
  eprint = {1905.04197},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/1905.04197},
}
Figure