Synthesis of Interplant Water-Allocation and Heat-Exchange Networks. Part 2: Integrations between Fixed Flow Rate and Fixed Contaminant-Load Processes
Lists
Only you see this
Abstract
Part 1 of the series proposes a multiscale state-space superstructure for interplant water-allocation and heat-exchange networks (IWAHENs) design with direct and indirect integration schemes in fixed flow rate (FF) processes (Zhou, R. J.; Li. L. J.; Dong, H. G.; Grossmann, I. E. Synthesis of Interplant Water-Allocation and Heat-Exchange Networks. Part 1: Fixed Flowrate Processes. Ind. Eng. Chem. Res. 2012, 51, 4299). Based on the same superstructure, part 2 of this series extends the IWAHEN integration methods to fixed contaminant-load (FC) processes as well as integration of FF and FC processes. The integrations are performed by solving the corresponding mixed-integer nonlinear programming (MINLP) models based on the multiscale state-space superstructure. Several relevant examples, including both direct and indirect integrations for IWAHENs, are presented to illustrate various aspects of the proposed approach.
BibTeX
@inproceedings{zhou2012synthesis,
author = {Rui‐Jie Zhou and Lijuan Li and Hongguang Dong and Ignacio E. Grossmann},
title = {{Synthesis of Interplant Water-Allocation and Heat-Exchange Networks. Part 2: Integrations between Fixed Flow Rate and Fixed Contaminant-Load Processes}},
booktitle = {Industrial},
year = {2012},
doi = {10.1021/ie3019752},
}Loading related content...