SurgAtt-Tracker: Online Surgical Attention Tracking via Temporal Proposal Reranking and Motion-Aware Refinement

Rulin Zhou, Guankun Wang, An Wang, Yujie Ma, Lixin Ouyang, Bolin Cui, Junyan Li, Chaowei Zhu, Mingyang Li, Ming Chen, Xiaopin Zhong, Peng Lu, Jiankun Wang, Xianming Liu, Hongliang RenarXiv 2026

TL;DR

SurgAtt-Tracker is a novel spatio-temporal framework that tracks a surgeon's visual focus as a dense attention heatmap during minimally invasive surgery. By shifting away from direct regression to a proposal-reranking and motion-aware refinement strategy, it achieves state-of-the-art tracking stability even under challenging conditions like smoke, glare, and tool occlusion.

What Problem Does This Paper Address?

In minimally invasive surgery (MIS), the laparoscope provides the primary visual interface for the surgeon. Traditionally, a surgical assistant manually manipulates the camera to maintain an optimal Field-of-View (FoV). However, prolonged procedures lead to assistant fatigue, resulting in shaky imagery, unintended drifting, and communication delays that can elevate patient risk.

While automated camera control systems exist, they typically rely on explicit inputs (like gaze or voice tracking) or simplistic rules like centering the camera on the dominant surgical tool. These heuristics fail during complex multi-instrument maneuvers or rapid focus shifts. Furthermore, modeling a surgeon's visual attention is incredibly challenging: it is a latent cognitive state without explicit visual markers, and frame-wise object detectors suffer from extreme instability due to intraoperative smoke, fluid pooling, and occlusions.

Figure 1. SurgAtt-Tracker enables AI-guided endoscope control by predicting an attention heatmap from raw endoscopic video.

Methods

Instead of directly regressing a heatmap from raw video frames, the authors treat attention tracking as a two-step proposal evolution problem:

  1. Hypothesis Generation: A strong, pre-trained object detector (such as YOLOv12) is kept in a frozen state to act as a high-recall proposal generator, outputting a set of Top-$K$ bounding box candidates for each frame.
  2. Multi-Scale ROI Decoder (MSR): Bounding box candidates are mapped back into the continuous semantic space of the detector's feature pyramids to capture both fine-grained textures and global context.
  3. Attention Score Rerank Module (AS-Rerank): Rather than trusting the detector's static, per-frame confidence scores (which fluctuate wildly due to glare or smoke), this module uses a cross-frame cross-attention mechanism. It compares current proposals against a trusted reference frame's region of interest (ROI) to select the candidate with the highest temporal consistency.
  4. Motion-Aware Adaptive Refinement (MAA-Refine): To fix discretization errors from the detector's anchor grid, this module continuously adjusts the selected box's center and scale. Crucially, it uses a polar-based formulation—decoupling shift direction from magnitude—which provides a more stable geometric constraint in low-texture surgical scenes.

Finally, the refined bounding box anchor is transformed into a continuous, temporally decaying dense attention heatmap to simulate human visual persistence.

Figure 3. Overview of SurgAtt-Tracker. A frozen detector produces Top-K proposals and multi-scale pyramid features, which are converted into box-aligned embeddings by the Multi-Scale ROI Decoder (B); the AS-Rerank module performs temporal proposal reranking to select the Top-1 attention region (C), and MAA-Refine further refines it using motion-aware geometry (D) and visual evidence to yield the attention heatmap Ht.

Datasets

To train and systematically evaluate the model, the authors introduced SurgAtt-1.16M, a massive multi-institutional benchmark comprising 1.16 million frames across diverse surgical procedures:

  • SurgAtt-SZPH: A newly curated dataset containing ~1.12M frames (125 clips) derived from 141 hours of real-world rectal and gastric cancer resections. It features a clinically grounded annotation protocol mapping discrete expert rules to continuous heatmaps.
  • AutoLaparo & Hamlyn: Re-labeled versions of existing public datasets covering gynecology (uterus hysterectomy) and urology (kidney nephrectomy) to rigorously test cross-domain generalization.
Figure 2. Overview of the SurgAtt-1.16M dataset, illustrating its anatomical coverage, data sources, and unified organization across organs, procedures, and annotation types.

Key Insights and Ideas

  • High Recall Over Top-1 Accuracy: While a standard detector's "Top-1" prediction is highly unstable in surgical environments, the true attention target is almost always present within its Top-$K$ proposals. Reranking based on temporal context effectively salvages these "near-miss" hypotheses.
  • Attention as a Continuous, Decaying Process: Human attention doesn't instantaneously vanish when a tool moves. Modeling attention as a temporally decaying Gaussian process smoothly bridges the gap between discrete tool-tissue interactions and continuous visual focus.
  • Polar vs. Cartesian Refinement: Predicting standard Cartesian offsets ($x, y$) is highly ambiguous when tracking soft, shifting tissues. Decoupling the update into a directed step (angle $\theta$ and magnitude $d$) forces the network to learn more robust geometric constraints.

Key Results

  • State-of-the-Art Tracking: SurgAtt-Tracker significantly outperformed all U-Net, regression, tracking, and detection baselines. On the SurgAtt-SZPH dataset, it achieved a Normalized Scanpath Saliency (NSS) of 2.580 and a Pearson Correlation Coefficient (CC) of 0.871, slashing pixel-wise errors (MSE/MAE) by up to 40% compared to strong detectors like RT-DETRv2.
  • Online Efficiency: The framework runs at 12.5 FPS in an online setting, making it highly viable for closed-loop robotic endoscope control loops.
  • Robust Generalization: In zero-shot cross-domain testing, the model transferred seamlessly to completely unseen organs, resolutions, and procedures (AutoLaparo and Hamlyn), maintaining compact, single-mode attention maps where other methods suffered severe spatial drift.
Figure 4. Qualitative comparison of attention heatmaps across diverse surgical scenarios: (A) single-instrument case; (B) multi-instrument without tissue interaction; (C) multi-instrument with tissue interaction; (D) multi-instrument with smoke interference.

Limitations and Future Work

  • Proposal Dependency: Because the tracker relies on a frozen detector, it is fundamentally bounded by the detector's proposal coverage; if the true target isn't in the initial Top-$K$ pool, the system cannot recover it.
  • Abrupt Camera Movements: While robust to standard motion, extremely sudden camera jerks or prolonged, complete occlusions can still cause tracking drift.
  • Downstream Integration: The current work focuses strictly on attention estimation. Future work will focus on directly integrating this continuous heatmap signal into active robotic hardware for fully automated, closed-loop camera control.

Summary updated

Abstract

Accurate and stable field-of-view (FoV) guidance is critical for safe and efficient minimally invasive surgery, yet existing approaches often conflate visual attention estimation with downstream camera control or rely on direct object-centric assumptions. In this work, we formulate surgical attention tracking as a spatio-temporal learning problem and model surgeon focus as a dense attention heatmap, enabling continuous and interpretable frame-wise FoV guidance. We propose SurgAtt-Tracker, a holistic framework that robustly tracks surgical attention by exploiting temporal coherence through proposal-level reranking and motion-aware refinement, rather than direct regression. To support systematic training and evaluation, we introduce SurgAtt-1.16M, a large-scale benchmark with a clinically grounded annotation protocol that enables comprehensive heatmap-based attention analysis across procedures and institutions. Extensive experiments on multiple surgical datasets demonstrate that SurgAtt-Tracker consistently achieves state-of-the-art performance and strong robustness under occlusion, multi-instrument interference, and cross-domain settings. Beyond attention tracking, our approach provides a frame-wise FoV guidance signal that can directly support downstream robotic FoV planning and automatic camera control.
BibTeX
@misc{zhou2026surgatt,
  author = {Rulin Zhou and Guankun Wang and An Wang and Yujie Ma and Lixin Ouyang and Bolin Cui and Junyan Li and Chaowei Zhu and Mingyang Li and Ming Chen and Xiaopin Zhong and Peng Lu and Jiankun Wang and Xianming Liu and Hongliang Ren},
  title = {{SurgAtt-Tracker: Online Surgical Attention Tracking via Temporal Proposal Reranking and Motion-Aware Refinement}},
  year = {2026},
  eprint = {2602.20636},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2602.20636},
}

Loading related content...

Figure