Super-resolved imaging system with oversampling technology

Xin Zhang, Yanyan Liu, Jianping Zhang, Lingjie WangProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 2007 · DOI

Abstract

It has been a significant issue in the imaging filed to provide the highest possible resolution of an electro-optical imaging system(E-O imaging system). CCD arrays are inherently undersampled and spatial frequency above Nyquist frequency is distorted so as to create ambiguity and Moire patterns for targets imaged by E-O system.. As to this drawback, a system-design project is introduced and discussed in the paper. It's well known that many image quality metrics are linked to MTF. However, CCDs don't satisfy MTF condition, namely, the shift-invariant property, so MTF synthesis can't appraise the whole system simply by the MTF product of the few sub-system ones in E-O imaging system. Then it is depicted how to solve this problem in the following. Finally the analyses and comparisons of the imaging performance parameters with and without super-resolved technologies are shown.
BibTeX
@inproceedings{zhang2007super,
  author = {Xin Zhang and Yanyan Liu and Jianping Zhang and Lingjie Wang},
  title = {{Super-resolved imaging system with oversampling technology}},
  booktitle = {Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE},
  year = {2007},
  doi = {10.1117/12.782950},
}

Loading related content...