Subject-Relative Micro-Motion and Sleep Dynamics for Near-Infrared Video Sleep Staging

Kunmin Jang, You Rim Choi, Hun Heo, Heonjun Lee, Suahn Bae, Dongik Park, Hyun-Woo Shin, Hyung-Sin KimNeurIPS 2026

TL;DR

Clinical sleep tracking usually requires being wired up like a lab rat, while existing camera-based alternatives try to indirectly reconstruct heartbeats or breathing waves—a brittle process easily ruined by a thick blanket. This paper introduces ViNUSS, a framework that predicts sleep stages directly from raw, nighttime near-infrared (NIR) video alone. Remarkably, it performs just as well as pipelines fed actual contact-sensor data, proving that raw video of subtle, localized body movements is a rich standalone signal for understanding sleep.

What Problem Does This Paper Address?

The gold standard for sleep staging—classifying 30-second windows ("epochs") into Wake, Light, Deep, or REM sleep—is polysomnography (PSG). PSG tracks brain waves, eye movements, and muscle tone via contact sensors. It is accurate, uncomfortable, and terrible for long-term home monitoring.

Contactless NIR cameras work in the dark and offer a great alternative. However, recent video-based methods treat video merely as a stepping stone to extract 1D physiological proxies (like chest-breathing waveforms or remote heart rate) or align video with EEG brainwave teachers. In real bedrooms, blankets, shifting postures, and blurred faces (for privacy) corrupt those reconstructed waveforms, and 1D compression throws away rich spatial movements.

Figure 1: Frequency analysis and respiratory reconstruction from NIR sleep video. (a) Video frequency maps from pixel-wise FFT over 0.17–0.30 Hz; brighter regions indicate stronger periodic motion. (b) Contact thoracic spectra from chest-belt signals. (c) Video-reconstructed respiratory waveforms.

Can we skip the middleman and infer PSG-grade sleep stages from NIR video alone? Naive 3D action-recognition CNNs fail here: because a sleeping scene is mostly static, standard models fixate on high-contrast, irrelevant edges like blanket folds and cluster data by who the person is (body shape, camera angle) rather than what sleep stage they are in.

A baseline 3D CNN (right) fixates on static high-contrast edges like bedding folds and cables rather than the actual chest motion shown in frame differences (left).

Methods

The authors propose ViNUSS (Video-Native Unmediated Sleep Staging), combining a standard video backbone (MoViNet-A2) and state-space sequence models (Mamba) with three targeted innovations:

  1. Pixel-Wise Temporal Encoder (PTE): Standard video networks spatially pool pixels early, diluting tiny movements. Placed before the backbone, PTE applies short 1D temporal convolutions (1–3 second receptive fields) independently at every pixel. It captures tiny local oscillations and twitch onsets while keeping them anchored to where on the body they happened.
  2. Intra-Subject Discriminability Loss (ISDL): To stop the model from memorizing room geometry or body size, the authors use a triplet contrastive loss sampled within the same person's overnight recording. By comparing an epoch against other stages from that exact same night, the model learns stage-specific shifts relative to the sleeper's personal baseline.
  3. Sleep Dynamics Modeling (SDM): Sleep unfolds in structured cycles. Instead of smoothing labels at the end, SDM uses a two-scale Mamba hierarchy: ShortMamba condenses motion across a 30-second clip, and a bidirectional LongMamba connects those summaries across the entire ~8-hour night.
The two-scale Sleep Dynamics Modeling (SDM) module summarizes 30-second motion via ShortMamba and models full-night trajectories via Bidirectional LongMamba.

Datasets

The authors evaluate on the Korea Video Sleep Study (KVSS) dataset—a large, realistic clinical collection featuring far-field wall cameras, heavy blanket occlusion, diverse sleep apnea severities, and anonymized (blurred) faces.

  • Primary training/evaluation: 475 overnight NIR recordings (~3,250 hours, 5 fps) from Hospital A, split strictly by subject (335 train / 70 val / 70 test) with technician-scored PSG labels.
  • Cross-site transfer: Held-out recordings from two external KVSS sites (Hospitals B and C) featuring different patient demographics and camera angles.

Key Insights and Ideas

  • Explicit proxies aren't necessary—the video already has the signal: Feeding ground-truth chest-belt breathing and cardiac waveforms directly into ViNUSS yielded zero measurable improvement. The video-native representation already captures the relevant physiological rhythms—plus broader postural cues that 1D waveforms miss.
  • Emergent physiological tracking: Using an interpretability tool adapted for 3D sleep video (SVECAM), the authors show that without ever being told what "breathing" is, ViNUSS naturally locks onto the ribcage and abdomen during Deep sleep, oscillating in sync with ground-truth respiration, while shifting attention to limbs during brief arousals.
  • Self-calibration unlocks temporal smoothing: ISDL doesn't just separate sleep stages; it makes consecutive 30-second embeddings much smoother over time, giving the full-night Mamba model clean trajectories to reason over.

Key Results

  • Overall Staging: On KVSS (4-class: Wake, Light, Deep, REM), ViNUSS achieves 0.80 accuracy, 0.68 Cohen’s $\kappa$, and 0.78 macro-F1 (MF1).
  • Beating Baselines & Matching Oracles: A vanilla MoViNet-A2 scores just 0.50 MF1. Remarkably, ViNUSS (using only face-blurred video) matches or slightly edges out a representative proxy-first transformer (SleepVST) even when SleepVST is given "oracle" ground-truth breathing and heart waveforms from physical contact sensors (0.73–0.75 MF1).
  • Step-by-step Gains: Ablations show steady, complementary climbs in MF1: Baseline (0.50) $\rightarrow$ +PTE (0.55) $\rightarrow$ +ISDL (0.56) $\rightarrow$ +Full-night SDM (0.78).
  • Failure Modes & Transfer: Half of all errors are minor timing offsets right at stage transitions; most others happen when sleep apnea disrupts rhythmic breathing during Deep sleep. Zero-shot accuracy drops at external hospitals (0.61–0.63), but fine-tuning on ~75 subjects restores accuracy to 0.75–0.80.

Limitations and Future Work

Because the pixel-wise encoder is sensitive to camera geometry, zero-shot transfer to new hospitals suffers, and Deep sleep macro-F1 lags behind in-site scores even after fine-tuning due to class scarcity at external clinics. Additionally, KVSS is recorded at 5 fps in hospital rooms. Future directions include multi-site training for camera-angle invariance, testing in messy home bedrooms, exploring higher frame rates, and fusing NIR video with lightweight wearables.

Summary updated

Abstract

Near-infrared (NIR) video is a promising modality for contactless sleep monitoring, but recent video-based sleep staging methods often use it as a route to reconstructed respiratory/cardiac proxies or cross-modal physiological representations. We study video-only sleep staging under labels defined by polysomnography (PSG), where the model infers sleep stages from NIR video alone without explicit physiological proxy reconstruction or auxiliary physiological signal supervision. This tests whether NIR video itself can provide informative sleep-stage evidence, rather than only serving as an input for recovering physiological proxies. We propose ViNUSS (Video-Native Unmediated Sleep Staging), a framework that combines subject-relative micro-motion learning with full-night sleep dynamics modeling. Spatially anchored pre-spatial micro-motion encoding preserves localized temporal variation with its spatial context. Within-subject stage contrast learns stage cues with respect to each subject’s night-specific baseline. Two-scale sleep dynamics modeling captures within-epoch motion evolution and organizes epoch-level evidence into a coherent full-night sleep-stage trajectory. On 475 overnight NIR recordings (∼3,250 hours), ViNUSS achieves 0.80 accuracy and 0.78 macro-F1 for four-class sleep staging, and adding reconstructed or contact-sensor waveform proxies to its representation yields no measurable improvement. Interpretability analysis suggests attention to thoraco-abdominal periodic motion and gross body movements associated with arousals and position changes. These results support NIR video as an independently informative modality for PSG-defined sleep-stage estimation.
BibTeX
@inproceedings{jang2026subject,
  author = {Kunmin Jang and You Rim Choi and Hun Heo and Heonjun Lee and Suahn Bae and Dongik Park and Hyun-Woo Shin and Hyung-Sin Kim},
  title = {{Subject-Relative Micro-Motion and Sleep Dynamics for Near-Infrared Video Sleep Staging}},
  booktitle = {Advances in Neural Information Processing Systems},
  year = {2026},
  url = {https://openreview.net/forum?id=5WH6aA0LYO},
}
Figure