Study on the improvement of indoor thermal environment and enhancement of photovoltaic power generation performance by the self-driven ventilation of the passive SC-PV-EAHE system

Bojing Huang, Juan Zhao, Wenjie Zhang, Wu Ritu, Yongcai LiEnergy 2025 · DOI

Abstract

• Proposed and optimized a solar chimney-PV-earth-air heat exchanger system via GA. • Over the daily cycle, achieved max 11.17 °C cooling, 1.43 % efficiency gain. • Over the annual cycle, Max temperature change: +9.58 °C (winter), −16.13 °C (summer). • Annual energy output increased by 91.96 kWh. This study established an unsteady-state mathematical model for the Solar Chimney-Photovoltaic-Earth to Air Heat Exchanger (SC-PV-EAHE) system, considering ventilation resistance and the synergistic effects of tunnel air, PV/T, and building thermal pressure on the dynamic indoor thermal environment. A full-scale test bench was constructed to conduct actual operating condition tests in different seasons. Genetic algorithms were used to optimize the key structural parameters of the system to improve its thermoelectric performance. The thermoelectric performance of Condition 1 (without the SC-PV-EAHE system), Condition 2 (with the SC-PV-EAHE system using experimental structural parameters), and Condition 3 (with the SC-PV-EAHE system using optimized structural parameters) were compared. Simulation results showed that compared to Condition 1, Conditions 2 and 3 had significant heating and cooling effects on indoor temperatures. On the hottest summer day, the daily average indoor temperatures for Conditions 2 and 3 decreased by 3.39 °C and 5.94 °C, respectively, with maximum cooling of 6.86 °C and 11.17 °C. The daily average electrical efficiency increased by 0.89 % and 1.43 %, respectively. In winter, the average indoor temperatures increased by 1.95 °C and 3.14 °C, with maximum heating of 5.79 °C and 9.58 °C. In summer, the average indoor temperatures decreased by 6.25 °C and 8.83 °C, with maximum cooling of 11.57 °C and 16.13 °C. The annual average electrical efficiencies of the PV modules were 20.65 %, 20.89 %, and 21.29 % for Conditions 1, 2, and 3, respectively. The annual power generation for Condition 1 was 2078.78 kWh, with Condition 2 increasing by 39.29 kWh and Condition 3 increasing by 91.96 kWh.
BibTeX
@inproceedings{huang2025study,
  author = {Bojing Huang and Juan Zhao and Wenjie Zhang and Wu Ritu and Yongcai Li},
  title = {{Study on the improvement of indoor thermal environment and enhancement of photovoltaic power generation performance by the self-driven ventilation of the passive SC-PV-EAHE system}},
  booktitle = {Energy},
  year = {2025},
  doi = {10.1016/j.enbenv.2025.04.008},
}

Loading related content...

Figure