Abstract
In order to improve environmental quality and purification capacity while reducing costs, this study investigates the use of biotechnology to control malodorous gas pollution. Specifically, a biofiltration method was employed to treat ammonia ($NH_3$) produced during waste composting. Experimental results showed that the system could effectively purify gases, achieving a removal rate of approximately 79.3% after one week and stabilizing at around 98% after 24 days. Monitoring the pH of the nutrient solution revealed a correlation between pH changes and the increase in removal rate. Biofiltration offers several advantages, including low energy consumption, high purification efficiency, environmental compatibility, and simple operation without secondary pollution, making it a promising technology for industrial odor control.
Introduction
As urban populations expand, municipal solid waste management has become a critical challenge. Composting is a preferred "harmless" disposal method, yet it generates significant amounts of malodorous gases, primarily ammonia. Ammonia is not only a nuisance but also a hazardous environmental pollutant that can cause respiratory distress and skin irritation at high concentrations. Traditional treatment methods often involve high energy costs or generate secondary pollutants. This research explores biofiltration as a "green," efficient, and low-cost alternative for industrial-scale odor control.
Methods and Experimental Setup
The researchers developed a biological filter tower divided into two layers. The packing material, which supports microbial growth, consisted of a mixture of compost and microporous medical stone (4–5 mm particles). This combination leverages the nutrients in compost and the high specific surface area of medical stone for biofilm attachment.
The system was inoculated with activated sludge containing aerobic bacteria and yeasts capable of denitrification. Simulated ammonia exhaust (initial concentration of 4.2 $mg/m^3$) was passed through a humidifier before entering the filter tower. Ammonia concentrations were measured using Nessler’s reagent colorimetric method, and the pH of the circulating nutrient solution was monitored daily to track the health and activity of the microbial colony.
Key Results and Discussion
The biofiltration system demonstrated high efficiency in removing ammonia over a 24-day period. The removal rate was not instantaneous, reflecting the time required for the biological film (biofilm) to mature and colonize the packing material.
As shown in Figure 2, the removal rate started at approximately 72% on day three and reached 79.3% after one week. By day 24, the system stabilized at a 98% removal rate, reducing the ammonia mass concentration from 4.2 $mg/m^3$ at the inlet to 0.87 $mg/m^3$ at the outlet. Correspondingly, the odor concentration dropped from 2500 to 37 (dimensionless), successfully meeting discharge standards.
An interesting observation was the pH trend. Initially, the pH rose to 8.4 due to the solubility of ammonia in water, which forms hydroxide anions. As nitrifying bacteria matured, they converted ammonia into nitrous and nitric acid, releasing hydrogen ions and causing the pH to eventually drop to 5.9. This shift confirms the biological nature of the purification process and the successful establishment of a nitrifying microbial community.
Conclusion and Future Outlook
Biofiltration proves to be a highly effective and sustainable method for controlling ammonia emissions from composting. The use of medical stone as a packing material helps prevent common issues like bed clogging or collapse. However, challenges remain for industrial scaling, including the relatively long startup time for biofilm formation and the need for long-term pH management to prevent excessive acidification. Future research should focus on accelerating the "membrane-forming" period and optimizing the recovery of nutrient solutions to ensure a truly zero-pollution process.
Summary updated