Study on gasifier high temperature measurement method based on heat conduction
Abstract
Because of high temperature molten slag and gas flow,the temperature measurement in an entrained-flow gasifier becomes very difficult.A simple and accurate method to measure the entrained-flow gasifier temperature is required in gasification industry.Based on one dimensional heat conduction,a device with gas sweeping and water cooling structure was designed to measure the high temperature in entrained-flow gasifier.Through the analysis of heat transfer process of the device,the formula was proposed to predict the temperature in gasifier,and the specific constant in the formula was calibrated by using calibration data in blackbody furnace.The device was used in a laboratory experimental entrained-flow gasifier with membrane water wall by using two kinds of gasification fuels.The results show that the device can estimate the experimental gasifier temperature accurately,and the method is suitable for the gasifier temperature measurement.
BibTeX
@inproceedings{meng2011study,
author = {Zhao Meng and Liang Qinfeng and Jianliang Xu and Haifeng Liu and Gong Xin},
title = {{Study on gasifier high temperature measurement method based on heat conduction}},
booktitle = {Chemical},
year = {2011},
}Ask Althea to put this paper to the test.