Study of Tuyere Combustion Flame Temperature in Vanadium and Titanium Blast Furnaces by Machine Vision and Colorimetric Thermometry

Haoyu Cai, Ziming Zhu, Dongdong ZhouMetals 2024 · DOI

TL;DR

This paper introduces a novel online system for measuring tuyere combustion flame temperature in vanadium-titanium blast furnaces using machine vision and colorimetric thermometry. This research addresses a critical gap in understanding and controlling these specialized furnaces, offering improved operational stability and paving the way for more intelligent, low-carbon steelmaking.

What Problem Does This Paper Address?

The steel industry is a cornerstone of the global economy but also a significant contributor to carbon emissions, with ironmaking being a major source. Enhancing the stability and quality of hot metal production is crucial for competitiveness and environmental sustainability. Vanadium-titanium blast furnaces present unique challenges due to the low fluidity of their slag, necessitating precise temperature control within a narrow range. However, a significant hurdle has been the lack of effective online monitoring systems for the tuyere combustion flame temperature, a key indicator of the furnace's thermal state and lower-part operations. This paper aims to fill this knowledge gap by developing and applying a system to capture and analyze this critical temperature data in real-time.

Methods

The core of this research lies in an integrated approach combining machine vision and colorimetric thermometry.

  • Online Detection System: A system was developed and installed on a 500 m³ vanadium-titanium blast furnace, featuring four charge-coupled devices (CCDs) positioned at the peepholes of four different tuyeres (east, south, west, and north). These CCDs capture radiation light emitted from the combustion zone.
  • Colorimetric Thermometry: This technique is employed to calculate the flame temperature. It relies on comparing the spectral radiant brightness of the thermal radiation at two different wavelengths. The paper derives and utilizes equations (1-3) to compute temperature (T) based on gray levels (Hλ), wavelengths (λ), Planck's radiation constants (C1, C2), and calibration coefficients (Nλ).
  • Blackbody Furnace Calibration: To ensure accurate temperature measurements, a high-temperature horizontal cylindrical standard blackbody furnace was used to calibrate the system. This process involved heating the blackbody to various temperatures (1500 °C to 2100 °C) and capturing calibration images to establish the relationship between gray levels and temperature.
  • Image Processing: Captured images undergo preprocessing, including denoising (using wavelet filtering) and edge extraction (using morphological edge detection). This is crucial to mitigate noise from dust and camera dark current, and to eliminate the influence of pulverized coal injection (PCI) blockage on the flame.
  • Imaging Parameter Optimization: The study investigated imaging parameters like aperture size and exposure time to ensure images were unsaturated and provided reliable data. The minimum aperture size was set to F16, and the maximum exposure time was determined to be 70 µs.
  • Data Analysis: The R-channel and G-channel of the CCD images were selected for analysis due to their stability compared to the B-channel. The research analyzed temperature variations over short intervals (1 minute) and longer periods (24 hours), as well as differences across the four tuyeres.

Datasets

The study utilized real-time data collected from a working 500 m³ vanadium-titanium blast furnace at Jianlong Steel. This involved capturing images of the tuyere combustion flame over a 7-day period. The paper also presents calibration data obtained from a blackbody furnace at temperatures ranging from 1500 °C to 2100 °C.

Key Insights and Ideas

  • The "Black Box" Opens: For the first time, this research provides a window into the otherwise opaque vanadium-titanium blast furnace, offering real-time insights into the critical tuyere combustion zone.
  • Colorimetric Thermometry's Efficacy: The study validates the application of colorimetric thermometry, combined with machine vision, as a viable method for non-contact temperature measurement in this harsh industrial environment.
  • Tuyere Temperature Asymmetry: A significant finding is the notable temperature difference (around 100 °C) observed between tuyeres in different directions, even when the overall temperature trend is similar. This highlights the importance of considering furnace asymmetry in operational control.
  • Hysteresis in Temperature Trends: The research confirms a significant hysteresis effect in the tuyere combustion flame temperature variation. This means temperature changes lag behind adjustments in operational parameters, a crucial factor for stable control.
  • Operational Parameter Influence: The study demonstrates that while blast temperature plays a role, increases in blast volume and PCI rate are more directly correlated with rising tuyere combustion flame temperatures, suggesting these are key levers for thermal management.

Key Results

  • The developed online detection system successfully captured real-time images of tuyere combustion flame temperature.
  • Colorimetric thermometry was used to calculate temperatures, with the R-channel and G-channel identified as suitable for analysis.
  • Calibration data showed a clear relationship between gray levels and temperature across a range of 1500 °C to 2100 °C.
  • The average temperature of the 1st and 4th tuyeres was found to be approximately 100-120 °C lower than the 2nd and 3rd tuyeres.
  • A temperature differential of about 100 °C was observed between tuyeres in different circumferential directions.
  • The study identified a hysteresis effect in temperature response to operational changes, with temperature declining only after sustained adjustments in hot blast volume, blast temperature, and PCI rate.

Limitations and Future Work

  • Tuyere-Specific Parameter Control: The paper notes the inability to measure blast volume and PCI rate for individual tuyeres, limiting the granularity of analysis. Future work could focus on developing methods for this more localized measurement.
  • Hysteresis Quantification: While hysteresis was observed, further quantitative analysis and modeling of this phenomenon could lead to more predictive control strategies.
  • Broader Application: The study focused on one specific blast furnace. Expanding this research to other vanadium-titanium blast furnaces would validate the findings and identify any furnace-specific variations.
  • Intelligent Control Integration: The authors suggest that this research provides technical support for intelligent and low-carbon operation. Future work could involve integrating this temperature monitoring system into advanced control algorithms for automated optimization.

Summary updated

Abstract

The steel industry is an important foundation of the national economy and the livelihood of the people, producing a large amount of carbon dioxide gas, accounting for about 70% of the carbon dioxide gas generated in the steel industry, which occurs during the ironmaking process. Therefore, the key technology to reduce the pollution and improve competitiveness is to increase the stability of blast furnace production and the quality of hot metal. Since the operation requirements for temperature control in the vanadium-titanium blast furnace are dramatically different compared to the traditional ones due to the low fluidity of vanadium-titanium slag, maintaining the required hot metal temperature within a narrow range with smaller fluctuations is essential. In addition, the adjustment parameters of the lower part have a significant influence on the tuyere combustion flame temperature during the daily operation of blast furnaces. At present, there is no relevant research on the online detection and analysis of vanadium-titanium blast furnace tuyere combustion flame temperature. In this study, the temperature of four tuyeres in a 500 m3 vanadium and titanium blast furnace at Jianlong Steel was detected by an online detection system. The tuyere combustion flame temperature was then calculated using colorimetric temperature measuring methodology at various times and at four distinct locations. After that, the calibration analyses, imaging parameter and the temperature tendencies in different directions of the blast furnace were investigated. This study not only offers new methods for understanding the regularity of operation and increasing the degree of visualization in vanadium and titanium smelting blast furnaces but also provides technical support for intelligent and low-carbon operation in blast furnaces.
BibTeX
@inproceedings{cai2024study,
  author = {Haoyu Cai and Ziming Zhu and Dongdong Zhou},
  title = {{Study of Tuyere Combustion Flame Temperature in Vanadium and Titanium Blast Furnaces by Machine Vision and Colorimetric Thermometry}},
  booktitle = {Metals},
  year = {2024},
  doi = {10.3390/met14050499},
}
Figure