Study of Temperature Field Distribution in Topographic Bias Tunnel Based on Monitoring Data

Tao Zhang, Lei Nie, Min Zhang, Shulin Dai, Yan Xu, Chao Du, Xiangjian Rui, Yuanyuan He, Yuzheng WangSymmetry 2021

TL;DR

This study investigates the temperature distribution within topographic bias tunnels in China's cold, monsoon-influenced regions, a critical area for preventing frost damage. By analyzing long-term monitoring data, the research reveals how tunnel construction and topography create asymmetrical temperature fields, offering valuable insights for tunnel design and frost protection in similar environments.

What Problem Does This Paper Address?

Tunnels are increasingly being built in China's cold regions, but understanding the temperature dynamics within these structures, especially those with topographic biases (i.e., built on slopes), remains a challenge. These "topographic bias tunnels" in monsoon freeze zones are particularly susceptible to frost damage, which can lead to structural issues like lining concrete cracking, peeling, and ice formation. While research exists on longitudinal temperature distributions in tunnels, there's a significant gap in understanding the transverse temperature variations in these specific, topographically influenced tunnels. This paper aims to fill that gap by providing a detailed analysis of the temperature field distribution in such tunnels, crucial for developing effective frost damage prevention strategies.

Methods

The researchers employed a long-term in-situ temperature monitoring approach. They installed temperature sensors at various depths within the surrounding rock of two topographic bias tunnel sections in the Huitougou Tunnel. These monitoring points were strategically placed along symmetrical measurement lines on the tunnel's cross-section.

The collected temperature data was then analyzed using two primary methods:

  • Short-term analysis: This focused on immediate temperature changes following excavation and construction activities, observing the impact of heat generated by blasting and concrete hydration.
  • Long-term analysis: This involved fitting the monthly average temperature data to a sinusoidal function (specifically, an annual period sine function) to model the seasonal temperature variations. This fitting was done using trigonometric functions and specialized software (Origin). The parameters of this fitted function (average temperature, amplitude, and phase difference) were then analyzed in relation to the distance from the tunnel wall.

Datasets

The study utilized monitoring data collected over 14 months (May 2015 to June 2016) from temperature sensors installed in two sections of the Huitougou Tunnel. This is a newly collected dataset specific to the studied tunnel sections and is not a pre-existing benchmark.

Key Insights and Ideas

  • Construction Heat is Significant (Short-Term): Blasting, and especially the hydration of primary and secondary lining concrete, causes a substantial, albeit temporary, increase in surrounding rock temperature within a 4-meter radius. This highlights the immediate thermal impact of construction activities.
  • Seasonal Sinusoidal Patterns: The surrounding rock temperature exhibits a clear annual sinusoidal variation, which can be effectively modeled. This is a fundamental insight into the long-term thermal behavior.
  • Distance Dampens and Delays: As the distance from the tunnel wall increases, the annual temperature fluctuations (amplitude) decrease, and the timing of peak and trough temperatures (phase difference) is delayed. This is intuitive, as the rock further from the tunnel is more insulated from external influences.
  • Asymmetry is the Norm: Topographic bias and construction factors lead to an inherent asymmetry in the temperature distribution across the tunnel's cross-section. This is a critical finding for understanding localized frost risk.
  • Freezing Depth Varies: The study provides an estimation of the freezing depth, noting that it's generally greater on the left side of the tunnel and deeper in Section 2 (closer to the entrance). This has direct implications for frost damage assessment.

Key Results

  • Temperature Variation: The annual maximum temperature of the surrounding rock generally decreased with distance from the tunnel wall, while the annual minimum temperature increased.
  • Parameter Trends: As distance from the tunnel wall increased, the mean annual temperature ($T_m$) increased, the annual temperature amplitude ($T_a$) decreased, and the phase difference ($t_c$) increased.
  • Asymmetry Quantification: Significant differences were observed in annual maximum and minimum temperatures between the left and right sides of the tunnel sections, with differences ranging from 0.3 to 1.6 °C.
  • Freezing Depth: The freezing depth was found to be greater on the left side of the tunnel than the right, and deeper in Section 2 compared to Section 1.

Limitations and Future Work

  • Limited Sections: The study focused on only two specific sections of the Huitougou Tunnel. While representative, more extensive monitoring across various tunnel types and geological conditions would strengthen the conclusions.
  • Influence of Construction: The short-term analysis was heavily influenced by construction heat. While this is a key finding, disentangling its long-term residual effects from natural seasonal variations could be a future direction.
  • Thermal Conductivity Speculation: The paper speculates that differences in thermal conductivity between gneiss and granitic gneiss might contribute to asymmetry in Section 1. Further investigation into the specific thermal properties of the surrounding rock could refine these explanations.
  • Topographic Deviation Impact: While topographic deviation is identified as a factor influencing asymmetry in Section 2, a more detailed quantitative analysis of its specific impact could be beneficial.

The authors suggest that their findings provide a reference for other studies on temperature distribution in deviated tunnels and offer guidance for frost protection measures in similar cold-region tunnels.

Summary updated

BibTeX
@article{zhang2021study,
  author = {Tao Zhang and Lei Nie and Min Zhang and Shulin Dai and Yan Xu and Chao Du and Xiangjian Rui and Yuanyuan He and Yuzheng Wang},
  title = {{Study of Temperature Field Distribution in Topographic Bias Tunnel Based on Monitoring Data}},
  journal = {Symmetry},
  year = {2021},
  doi = {10.3390/sym13081492},
}

Loading related content...

Figure