Stretchable, Highly Durable Ternary Nanocomposite Strain Sensor for Structural Health Monitoring of Flexible Aircraft

Feng Yin, Dong Ye, Chen Zhu, Lei Qiu, Yongan HuangSensors 2017 · OpenReview

TL;DR

Researchers have developed a highly durable and stretchable strain sensor using a ternary nanocomposite of PDMS, carbon black (CB), and multi-walled carbon nanotubes (MWCNTs). This sensor demonstrates excellent linearity, a high gauge factor, and remarkable durability, making it ideal for structural health monitoring of flexible aircraft like aerostats.

What Problem Does This Paper Address?

Traditional strain sensors, such as foil strain gauges, have limitations in terms of low gauge factors, limited deformation capabilities, and small measurement ranges. These shortcomings make them unsuitable for monitoring the large deformations (>10%) and complex structures found in modern flexible aircraft like morphing aircraft, inflated spacecraft, and aerostats. These systems require sensors that can conform to irregular surfaces, withstand significant stretching, and reliably detect damage like cracks without compromising their sensing function. Existing stretchable sensors often struggle with durability and stability under dynamic loads.

Methods

The researchers developed a ternary nanocomposite by homogeneously dispersing carbon black (CB) nanoparticles and multi-walled carbon nanotubes (MWCNTs) into a polydimethylsiloxane (PDMS) matrix. The synthesis involved ultrasonic dispersion of fillers in toluene, followed by magnetic stirring and degassing. The resulting nanocomposite was fabricated into thin films using screen printing and then transferred to various surfaces via a thermally released tape.

Key to their approach was the optimization of processing parameters:

  • Filler Optimization: They systematically varied the weight percentages of CB and MWCNTs to achieve a balance between electrical conductivity and strain sensitivity.
  • PDMS Ratio Optimization: The ratio of PDMS pre-polymer to curing agent was optimized to enhance mechanical properties, specifically tensile strength.
  • Characterization: Electrical conductivity was measured using a two-probe method. Strain-resistivity characteristics were evaluated using a custom re-stretching machine under cyclic loading. Tensile strength was determined using a universal testing machine, and transverse sensitivity was also assessed. Durability was tested over numerous stretching-releasing cycles.

Datasets

Not discussed in the paper. The study relies on experimental data generated from fabricated sensor samples.

Key Insights and Ideas

  • Synergistic Effect of Hybrid Fillers: Combining CB and MWCNTs in a ternary nanocomposite significantly enhances electrical conductivity and strain sensitivity compared to binary composites. The CB particles effectively bridge gaps between MWCNTs, forming a more robust conductive network.
  • Optimized Filler Ratio is Crucial: The study found that a specific combination of 1.75 wt% CB and 3 wt% MWCNTs yielded the best results for strain sensitivity, likely due to an optimal balance of tunneling and contact resistance.
  • PDMS Ratio Impacts Mechanical Strength: While filler content primarily affects electrical properties, the ratio of PDMS pre-polymer to curing agent critically influences the mechanical strength of the nanocomposite, with a 12.5:1 ratio proving optimal for tensile strength.
  • High Durability and Linearity: The developed sensor exhibits excellent durability, maintaining performance over 10⁵ stretching-releasing cycles at 25% strain, and shows a nearly linear response, which is highly desirable for accurate strain measurement.
  • Potential for Crack Detection: The sensor's sensitivity to resistance changes under strain was successfully demonstrated in detecting cracks on an aerostat composite, highlighting its practical application in structural health monitoring.

Key Results

  • Optimal Composition: The best-performing nanocomposite consisted of 1.75 wt% CB and 3 wt% MWCNTs dispersed in PDMS at a 12.5:1 pre-polymer to curing agent ratio.
  • High Gauge Factor (GF): The sensor achieved a GF of approximately 12.25, significantly higher than conventional foil strain gauges (~2.2).
  • Excellent Durability: The sensor maintained good reproducibility and durability over 10⁵ stretching-releasing cycles at up to 25% tensile strain.
  • Linear Strain Response: The resistance change ratio showed a nearly linear response to tensile strain up to 25%.
  • Low Transverse Sensitivity: The transverse sensitivity was approximately 26%, which is considered a good result for this type of sensor.
  • Crack Detection: The sensor successfully detected crack propagation in an aerostat composite, with the resistance change ratio correlating with crack length.

Limitations and Future Work

  • Viscous Hysteresis: The paper acknowledges a slight viscous hysteresis and a small increase in resistance change ratio during the recovery process, attributed to the viscoelastic nature of the PDMS matrix and filler slippage.
  • Temperature Sensitivity: While negligible at lower temperatures, the sensor exhibits a positive temperature coefficient effect above 60°C due to thermal expansion and PDMS flow. The authors suggest that a temperature-compensated algorithm can be developed to mitigate this.
  • Transverse Sensitivity Improvement: While the transverse sensitivity is good, it could be further enhanced by external special processing circuits in future work.
  • Crack Detection Specificity: While crack detection was demonstrated, further work could explore more quantitative analysis of crack size and propagation using the sensor.
  • Application Expansion: The authors suggest the huge applications in SHM of flexible systems, implying further research into morphing aircraft, inflated spacecraft, and aerostats.

Summary updated

Abstract

Harmonious developments of electrical and mechanical performances are crucial for stretchable sensors in structural health monitoring (SHM) of flexible aircraft such as aerostats and morphing aircrafts. In this study, we prepared a highly durable ternary conductive nanocomposite made of polydimethylsiloxane (PDMS), carbon black (CB) and multi-walled carbon nanotubes (MWCNTs) to fabricate stretchable strain sensors. The nanocomposite has excellent electrical and mechanical properties by intensively optimizing the weight percentage of conducting fillers as well as the ratio of PDMS pre-polymer and curing agent. It was found that the nanocomposite with homogeneous hybrid filler of 1.75 wt % CB and 3 wt % MWCNTs exhibits a highly strain sensitive characteristics of good linearity, high gauge factor (GF ~ 12.25) and excellent durability over 105 stretching-releasing cycles under a tensile strain up to 25% when the PDMS was prepared at the ratio of 12.5:1. A strain measurement of crack detection for the aerostats surface was also employed, demonstrating a great potential of such ternary nanocomposite used as stretchable strain sensor in SHM.
BibTeX
@inproceedings{yin2017stretchable,
  author = {Feng Yin and Dong Ye and Chen Zhu and Lei Qiu and Yongan Huang},
  title = {{Stretchable, Highly Durable Ternary Nanocomposite Strain Sensor for Structural Health Monitoring of Flexible Aircraft}},
  booktitle = {Sensors},
  year = {2017},
  url = {https://openreview.net/forum?id=oyKYYSkB2E},
}
Figure