This paper introduces a novel method for embedding Fiber Bragg Grating (FBG) sensors directly into Glass Fiber-Reinforced Polymer (GFRP) anchors during manufacturing. This allows for real-time monitoring of axial forces and shear stresses along the anchor's depth during pullout tests, demonstrating the feasibility of FBG technology for GFRP anchor structural health monitoring.

What Problem Does This Paper Address?

Glass Fiber-Reinforced Polymer (GFRP) anchors are increasingly used in civil engineering due to their corrosion resistance and high strength-to-weight ratio, offering an alternative to traditional steel anchors. However, understanding the actual field behavior of these anchors, particularly the interaction between the GFRP material and the surrounding soil, is crucial for accurate design. Traditional strain gauges and extensometers are often unsuitable for anisotropic GFRP materials. While FBG sensors offer advantages like small size and good resolution, previous methods of attaching them to GFRP anchors could damage the material and affect accuracy. This paper addresses the need for a non-destructive and accurate method to monitor the stress distribution within GFRP anchors during load testing, providing insights into their performance and failure mechanisms.

Methods

The core innovation of this paper lies in the method of integrating FBG sensors into GFRP anchors. Instead of surface adhesion, bare FBG sensors were fused with an optical fiber at planned intervals. This fiber line was then embedded within the anchor mold during the extrusion molding process. This "smart anchor" manufacturing technique ensures the integrity of the GFRP material and allows for the FBG sensors to be an integral part of the anchor.

The study involved two GFRP anchors, each 8.85 meters long and 28 mm in diameter, instrumented with seven bare FBG sensors at various depths. These anchors were then installed in a subway construction site using a drilling and grouting method. After 28 days, pullout tests were conducted using a specialized loading device. The FBG sensors, connected to a SI425 interrogator system, provided real-time strain data. This strain data was then used to calculate axial forces and shear stresses along the anchor depth using established formulas relating strain to force and the mechanical properties of GFRP.

Datasets

Not discussed in the paper. The study relies on field test data collected from instrumented GFRP anchors.

Key Insights and Ideas

  • Integrated Sensing for Structural Integrity: Embedding FBG sensors directly into GFRP anchors during manufacturing is a game-changer. It avoids the damage associated with surface attachment and ensures the sensors accurately reflect the anchor's internal stress state.
  • Understanding GFRP Anchor Failure: The results suggest that GFRP anchors are more likely to fail due to interlaminar shear within the GFRP material itself, rather than at the grout-soil interface, which is a common failure mode for steel anchors. This highlights the importance of interlaminar shear strength in GFRP anchor design.
  • Critical Load Transfer Depth: The study identified a critical depth (approximately 4.0 m in this case) beyond which additional anchorage length does not significantly increase the pullout resistance. This is attributed to the extensibility of GFRP and large strains, suggesting that anchor capacity is governed by this critical depth rather than the total length if it exceeds this value.

Key Results

  • The embedded FBG sensing technology was successfully demonstrated as a feasible method for monitoring the stress distribution of GFRP anchors during pulling tests.
  • Axial forces within the GFRP anchors were found to decrease with depth under pulling forces, with distributions becoming nonlinear as pulling forces increased, indicating mobilization of shear stresses.
  • The maximum axial forces measured for GFRP-1 and GFRP-2 were around 300 kN, significantly lower than their theoretical ultimate tensile strength, suggesting localized failures.
  • Peak shear stresses were measured at approximately 1.94 MPa for GFRP-1 and 1.72 MPa for GFRP-2.
  • A critical load transferring depth of approximately 4.0 m was identified for the tested GFRP anchors.

Limitations and Future Work

  • Temperature Effects: While the study acknowledges temperature variations, it states that they were not considered due to the short duration of the pulling tests. However, for long-term monitoring, temperature compensation for FBG sensors would be crucial.
  • Limited Number of Anchors: The study involved only two instrumented GFRP anchors. Further testing with a larger sample size and under various soil conditions would enhance the generalizability of the findings.
  • Future Work: The authors suggest that the interlaminar shear strength of GFRP materials is a critical parameter for evaluating pullout resistance. Future research could focus on further investigating this aspect and its influence on the critical load transfer depth. Additionally, exploring the long-term performance and durability of these embedded FBG sensors in GFRP anchors would be valuable.