Statistical analysis of dark count rate in Geiger-mode APD FPAs
Abstract
We present a temporal statistical analysis of the array-level dark count behavior of Geiger-mode avalanche photodiode (GmAPD) focal plane arrays that distinguishes between Poissonian intrinsic dark count rate and non-Poissonian crosstalk counts by considering “inter-arrival” times between successive counts from the entire array. For 32 x 32 format sensors with 100 μm pixel pitch, we show the reduction of crosstalk for smaller active area sizes within the pixel. We also compare the inter-arrival time behavior for arrays with narrow band (900 - 1100 nm) and broad band (900 - 1600 nm) spectral response. We then consider a similar analysis of larger format 128 x 32 arrays. As a complement to the temporal analysis, we describe the results of a spatial analysis of crosstalk events. Finally, we propose a simple model for the impact of crosstalk events on the Poissonian statistics of intrinsic dark counts that provides a qualitative explanation for the results of the inter-arrival time analysis for arrays with varying degrees of crosstalk.
BibTeX
@inproceedings{itzler2014statistical,
author = {Mark A. Itzler and Uppili Krishnamachari and Quan Chau and Xudong Jiang and Mark Entwistle and Mark Owens and Krystyna Slomkowski},
title = {{Statistical analysis of dark count rate in Geiger-mode APD FPAs}},
booktitle = {Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE},
year = {2014},
doi = {10.1117/12.2068744},