Spatiotemporal Rule of Heat Transfer on a Soil/Finned Tube Interface

Yongsheng Huang, Wenbin Li, Daochun Xu, Yafeng WuSensors 2019 · DOI

TL;DR

This paper investigates the spatiotemporal heat transfer dynamics at the interface between soil and a finned tube heat exchanger, crucial for efficiently harvesting shallow soil's environmental micro-energy. By combining simulation, theoretical analysis, and field experiments, the authors developed empirical formulas to predict temperature and heat flux, demonstrating that finned tubes significantly enhance heat extraction compared to bare tubes, especially in moist soil conditions.

What Problem Does This Paper Address?

Powering remote wireless sensors, particularly in environments like forests, presents a significant challenge. A promising solution involves harnessing the temperature difference between the forest soil and the ambient air to generate electricity using thermoelectric generators (TEGs). This process relies on efficiently transferring heat from the shallow soil to the TEG. However, the heat transfer characteristics at the interface between the soil and the heat exchanger (specifically, a finned tube designed to increase contact area) are complex and not fully understood. This paper aims to elucidate the spatiotemporal rules of heat transfer at this soil/finned tube interface, providing insights into optimal placement and design for maximizing energy harvesting.

Methods

The researchers employed a multi-faceted approach:

  • Simulated Analysis: They developed a two-dimensional finned tube model using ANSYS-Workbench. This model was used to simulate heat transfer under 36 different working conditions, varying soil temperature, soil moisture content, and finned tube initial temperature. This allowed for the derivation of empirical formulas for temperature and heat flux.
  • Theoretical Arithmetic: The heat transfer rate of the finned tube was compared to that of a bare tube using theoretical calculations.
  • Field Experiment: A thermoelectric power generation device equipped with the finned tube heat exchanger was buried in the soil in Harbin, China. Temperature data was collected over nine months to validate the simulation and theoretical findings.

Key assumptions for the model included isotropic soil, homogeneous temperature distribution at a given depth, negligible thermal contact resistance, and no internal heat generation. The simulation domain radius was determined to be 300 mm, and mesh independence was verified. Step time independence was also established, with a step time of 1.0 s and 9000 steps used in the simulations.

Datasets

The study utilized simulated data generated from the ANSYS-Workbench model under 36 distinct working conditions. These conditions were defined by variations in:

  • Soil temperature (Ts): 20 °C, 15 °C, 10 °C
  • Finned tube initial temperature (Tf): 15 °C, 10 °C, 5 °C
  • Soil moisture content (M): 10%, 15%, 20%, 25%, 30%, 35%

Additionally, real-world temperature and soil moisture data were collected from a field experiment conducted over nine months in Harbin, China.

Key Insights and Ideas

  • Finned Tubes are Key: The finned tube design significantly enhances heat transfer compared to a bare tube, with the authors reporting a 76.77% higher heat transfer rate for their copper finned tube. This is attributed to the increased contact area with the soil.
  • Moisture Matters (A Lot): Soil moisture content is a critical factor. The performance of the finned tube is considerably better when soil moisture reaches 30% or higher. Devices should ideally be placed in locations with at least 30% soil moisture for optimal heat transfer and faster equilibrium.
  • Spatiotemporal Dynamics Revealed: The study provides a detailed understanding of how temperature profiles evolve over time and space around the finned tube, showing that the finned tube's sphere of influence is limited, and temperatures at different points (T1, T2, T3, T4) respond differently based on their proximity to the heat exchanger.
  • Predictive Power: The derived empirical formulas for temperature (T3) and heat flux (q) are highly accurate, with goodness-of-fit (R²) values exceeding 97%, allowing for reliable prediction of performance under various conditions.
  • Real-World Validation: The field experiment in Harbin provided strong evidence that the simulation and theoretical models accurately represent real-world heat transfer dynamics, confirming the reliability of the empirical formulas.

Key Results

  • The highest heat flux achieved in simulations was approximately 0.30 mW/mm².
  • Under optimal conditions, approximately 1507.96 mW of energy can be harvested through the finned tube.
  • The heat transfer rate of the copper finned tube is 76.77% higher than that of a bare tube.
  • Soil moisture content above 30% leads to faster equilibrium states (around 6000 s) compared to lower moisture levels (over 9000 s).
  • Empirical formulas for T3 and heat flux showed R² values greater than 97%, indicating high accuracy.
  • Field experiment data closely matched the calculated T3 values, validating the theoretical analysis.

Limitations and Future Work

  • Assumptions: The study relies on several assumptions, including isotropic soil, homogeneous temperature distribution at a given depth, and negligible thermal contact resistance. Real-world soil conditions can be more complex.
  • Simplified Model: The mathematical model simplifies the finned tube as a cylinder for calculations, which might not capture all nuances of the complex geometry.
  • Limited Scope of Field Experiment: While the field experiment provided validation, it was conducted over nine months in a specific location. Further experiments across diverse geographical and climatic conditions would strengthen the findings.
  • Future Work: The authors suggest that their work is important for the use of geothermal energy. Future research could explore optimizing fin geometry, materials, and placement strategies for even greater energy harvesting efficiency in various environmental settings. Investigating the long-term performance and degradation of the system would also be valuable.

Summary updated

BibTeX
@article{huang2019spatiotemporal,
  author = {Yongsheng Huang and Wenbin Li and Daochun Xu and Yafeng Wu},
  title = {{Spatiotemporal Rule of Heat Transfer on a Soil/Finned Tube Interface}},
  journal = {Sensors},
  year = {2019},
  doi = {10.3390/s19051159},
}