TL;DR
When AI radiology assistants read a patient’s old medical records alongside today’s chest X-ray, they sometimes hallucinate that past conditions still exist—even if those conditions have completely healed. This paper introduces a clever counterfactual stress test—swapping in another patient’s medical history while keeping today’s X-ray fixed—to measure this exact "historical carryover" bias. Better yet, the authors build a lightweight, text-only "traffic controller" that wraps around existing AI models, filtering out ghostly past findings while preserving genuinely useful historical context.
What Problem Does This Paper Address?
Radiology is rarely a single snapshot; it’s a movie. When human radiologists read a chest X-ray, they compare it against prior scans and reports to see if a shadow is a dangerous new development or just a stubborn old scar. Naturally, modern medical vision-language models (like MAIRA-2) are now fed prior images and reports too.
Here’s the catch: language models love a good, consistent story. If a previous report mentions a "small pleural effusion," the AI might confidently state that the effusion persists today, even if the current X-ray is crystal clear.
Standard evaluation metrics struggle to catch this. Feeding history into an AI often boosts its "recall" (catching more real findings mentioned in the reference report), which makes overall quality scores look great on paper—even while it quietly inflates false positives. How do we separate legitimate, history-aware insight from an AI blindly parroting the past?
Methods
The authors tackle this in two steps: an offline diagnostic audit and a deployment-time controller.
First, they introduce source-causal robustness. Holding the current X-ray completely fixed, they run a frozen AI generator under five historical conditions: no history (current-only), valid prior images + text, valid prior text alone, a random stranger’s history, and a matched wrong-history—a stranger’s history chosen because their clinical profile looks deceptively plausible for this type of scan. By tracking 11 clinical finding categories, they measure exactly how much the AI’s diagnosis bends toward the supplied text.
Second, to tame this behavior without retraining massive models, they build the Source-Causal Finding Router (SCFR)—a lightweight, post-generation text controller.
At deployment, SCFR never looks at pixels. Instead, it:
- Calls the frozen generator three times on the real patient's data (
current-only,prior images + report, andprior report only). - Builds four alternative proposals: two via rankers weighted toward either recall or precision, and two via logistic "finding verifiers" that surgically delete unsupported positive sentences from the
current-onlyreport or append compact canonical statements. - Feeds these four proposals—plus the untouched
current-onlyreport as a safe anchor—into a tiny, 19-feature linear router (an averaged structured perceptron) that picks one winning report unchanged.
Datasets
- MIMIC-CXR & MIMIC-CXR-JPG: Used to construct 18,716 longitudinal chest X-ray pairs (yielding 93,580 generated reports across the five audit arms), alongside three 1,000-study parent cohorts and 300-study controller evaluation subsets.
- Structured Audit Benchmarks: Existing resources—ReXPref-Prior, RadGraph2, and Chest ImaGenome—are used to audit unsupported references to prior exams, temporal entity relations, and anatomical grounding. No new dataset is released, though the authors provide an offline counterfactual audit framework over MIMIC-CXR.
Key Insights and Ideas
- Plausible wrong history fools standard recall metrics: Giving MAIRA-2 another patient’s matched history actually reduces false negatives (by 0.129 per report) because common findings overlap, while spiking false positives by nearly 50% (+0.366 per report). Improved recall alone does not prove an AI is using history validly!
- It’s not just copy-pasting: When wrong history triggers false positive additions, only 2.0% are near-verbatim string copies from the prior report, while 31.8% re-introduce the clinical concept in fresh phrasing. Simple lexical overlap filters can't solve this; you have to operate at the clinical finding level.
- Different AI backbones react differently to history: While MAIRA-2 becomes trigger-happy under wrong history (trading higher false positives for lower false negatives), other longitudinal models like RadInfer and Libra respond differently—Libra actually lowers false positives while spiking false negatives. One size does not fit all.
Key Results
- Eliminating stress-induced errors: Across three aligned 300-study subsets, SCFR cuts proxy false positives relative to matched wrong-history by 0.343 to 0.550 per report ($p \le .0012$), repairing 92.7% to 108.4% of the wrong-history false-positive excess while staying strictly within
current-onlyquality tolerances. - Selective, smart routing: Rather than lazily defaulting to
current-onlyevery time, SCFR actively selects history-informed reports in 139 out of 900 cases, slashing unsupported prior-exam cues from 14.6% down to 0.8% on ReXPref-Prior. - Radiologist validation: In a blinded review of 60 X-rays, a radiologist found that 72.7% (8/11) of resolved additions under matched wrong-history were completely unsupported by the actual image, compared to 38.9% (7/18) under real history—confirming that text proxies track real visual hallucinations.
Limitations and Future Work
- Compute overhead: SCFR requires three generator calls per exam instead of one, assuming valid patient-aligned history is available.
- Dataset & training overlap: Evaluation is retrospective on MIMIC-CXR, where primary generators like MAIRA-2 already had training-domain exposure.
- Small human-reader sample: Image-grounded calibration relied on a single radiologist, small resolved-addition denominators, and yielded inconclusive overall preference in the 30-case active-route comparison (13 for SCFR vs. 17 for
current-only). - Future work: The authors call for prospective, multi-reader clinical studies before any real-world deployment to rigorously evaluate clinical omissions, temporal accuracy, and human automation bias.
Summary updated