Abstract

The integration of artificial intelligence (AI) and machine learning (ML) into healthcare systems holds great promise for enhancing patient care and care delivery efficiency; however, it also exposes sensitive data and system integrity to potential cyberattacks. Current security and privacy (S&P) research on healthcare AI is highly unbalanced in terms of healthcare deployment scenarios and threat models, and has a disconnected focus with the biomedical research community. This hinders a comprehensive understanding of the risks that healthcare AI entails. To address this gap, this paper takes a thorough examination of existing healthcare AI S&P research, providing a unified framework that allows the identification of under-explored areas. Our survey presents a systematic overview of healthcare AI attacks and defenses, and points out challenges and research opportunities for each AI-driven healthcare application domain. Through our experimental analysis of different threat models and feasibility studies on under-explored adversarial attacks, we provide compelling insights into the pressing need for cybersecurity research in the rapidly evolving field of healthcare AI.

Introduction

Artificial Intelligence is no longer a futuristic concept in medicine; it is a rapidly expanding market projected to reach $188 billion by 2030. However, as healthcare systems increasingly rely on AI for critical tasks—from diagnostics to therapeutic planning—they become vulnerable to sophisticated cyberattacks. This "Systematization of Knowledge" (SoK) paper reveals a dangerous disconnect between the rapid deployment of healthcare AI and our current understanding of its security and privacy (S&P) vulnerabilities. While the biomedical community focuses on diagnostic accuracy, the security community has largely focused on abstract or "standard" AI tasks, leaving a significant gap in clinical-specific security research.

The Research Disconnect and Imbalance

A systematic survey of over 3,000 articles reveals a massive imbalance in the current research landscape. As shown in Figure 1, while biomedical publications have seen explosive growth, security-focused research in the healthcare AI domain remains disproportionately low and lacks a consistent upward trend.

Publication trends in Biomedical vs. Security domains, highlighting the research gap.

The authors identify three primary areas of concern:

  1. Domain Skew: Most security research focuses on medical image classification, leaving areas like disease risk prediction and therapeutic effect prediction largely ignored.
  2. Threat Model Disconnect: Existing literature often assumes "honest-but-curious" cloud providers, ignoring realistic threats like malicious patients attempting to manipulate surgery waitlists or practitioners committing insurance fraud.
  3. The Generative Gap: Despite the rise of Generative AI and multi-modal foundation models (e.g., BiomedCLIP), there is almost zero research into their adversarial robustness in clinical settings.

A Unified Threat Framework

To bridge this gap, the authors propose a unified framework for understanding adversarial threats across various healthcare settings. This framework categorizes adversarial knowledge, identity, and capability against specific clinical, administrative, and research tasks.

A unified framework for understanding adversarial threats in healthcare AI settings.

Crucially, the framework highlights that healthcare practitioners possess unique capabilities, such as "Query Access" and "Explanation Access." These can be leveraged to reverse-engineer model behavior or craft adversarial inputs to justify unnecessary treatments, presenting a threat model rarely explored in standard AI security literature.

Experimental Validation: Proof-of-Concept Attacks

To fill the identified gaps, the researchers conducted original attacks on high-stakes clinical datasets, including MIMIC-III (ICU data) and PhysioNet (ECG recordings).

Evasion and Foundation Models

Testing BiomedCLIP, a state-of-the-art multi-modal foundation model, the authors found it highly fragile. Under a standard perturbation budget ((\epsilon = 8/255)), an untargeted PGD attack reduced the model's accuracy from near-perfect to just 5%. This demonstrates that models connecting text and images can be easily "fooled" into misclassification, potentially leading to fraudulent claims.

Backdoor Attacks in Time-Series Data

In time-series data like ECGs, the authors successfully injected "invisible" triggers (e.g., a simple cosine wave). By poisoning only 5% of the training data, they achieved a 97.67% backdoor success rate. These triggers are mathematically significant to the neural network but remain completely invisible to human cardiologists.

Privacy and Availability

The study also confirmed that ECG-based models are as vulnerable to Membership Inference Attacks (MIA) as standard image models, risking the leakage of sensitive patient participation in clinical trials. Furthermore, Availability Attacks using label-flipping in mortality prediction models reduced accuracy by 77%, effectively rendering critical triage tools useless.

Conclusion and Future Directions

The paper concludes that the security of healthcare AI requires urgent, domain-specific attention. Future work must address "Fairness Attacks," where adversaries manipulate models to become biased against specific demographics, and navigate the "Explainability Paradox"—where XAI helps doctors trust models but also provides a roadmap for attackers. Balancing transparency with security remains a primary challenge for the next generation of medical AI.

Summary updated

Abstract

The integration of artificial intelligence (AI) and machine learning (ML) into healthcare systems holds great promise for enhancing patient care and care delivery efficiency; however, it also exposes sensitive data and system integrity to potential cyberattacks. Current security and privacy (S&P) research on healthcare AI is highly unbalanced in terms of healthcare deployment scenarios and threat models, and has a disconnected focus with the biomedical research community. This hinders a comprehensive understanding of the risks that healthcare AI entails. To address this gap, this paper takes a thorough examination of existing healthcare AI S&P research, providing a unified framework that allows the identification of under-explored areas. Our survey presents a systematic overview of healthcare AI attacks and defenses, and points out challenges and research opportunities for each AI-driven healthcare application domain. Through our experimental analysis of different threat models and feasibility studies on under-explored adversarial attacks, we provide compelling insights into the pressing need for cybersecurity research in the rapidly evolving field of healthcare AI.

Empirical ResultsBrowse all benchmarks →

BenchmarkMethodMetricScoreProtocol / Evidence
BiomedCLIP biomedical image classificationBiomedCLIP; untargeted PGD attackaccuracy0.05split: test · norm=L-infinity · attack=untargeted-PGD · epsilon=8/255 · evaluation-size=100 correctly classified images
Source quote
L331: The results are shown in Table~\ref{tab:adv_biomedclip}, which indicate that white-box adversarial attacks remain highly effective against multi-modal foundation models. For instance, under a perturbation budget of 8/255, the untargeted PGD attack reduces the model's accuracy to 0.05. Figure~\ref{fig:adv_visu} provides examples of original and adversarial images, demonstrating the imperceptibility of the adversarial perturbations.
2017 PhysioNet/CinC Challenge ECG datasetCosine-waveform backdoor attack on a 13-layer CNNbackdoor accuracy97.67%model=13-layer-CNN · attack=cosine-waveform-backdoor · trials=5 · target-label=AF · poisoning-ratio=0.05
Source quote
L361: Figure~\ref{fig:backdoor_result} demonstrates that ECG diagnostic CNN is highly vulnerable to our proposed backdoor attacks. With a trigger length that is only 2% of the recording length and a poisoning ratio of 0.05, backdoor accuracy reached 97.67% without significantly affecting the benign accuracy. In the normal setting, the accuracy is 85.08%, while the benign accuracy drops only 2% (83.05%). Furthermore, backdoor performance improves with increased poisoning ratio and trigger length. When the trigger length ratio is 2% and the poisoning ratio is 0.01, backdoor accuracy is 0%. However, when the poisoning ratio is 0.1 and the length ratio is 5%, backdoor accuracy reaches nearly 100%.
2017 PhysioNet/CinC Challenge ECG datasetCosine-waveform backdoor attack on a 13-layer CNNbenign accuracy83.05%model=13-layer-CNN · attack=cosine-waveform-backdoor · trials=5 · target-label=AF · poisoning-ratio=0.05
Source quote
L361: Figure~\ref{fig:backdoor_result} demonstrates that ECG diagnostic CNN is highly vulnerable to our proposed backdoor attacks. With a trigger length that is only 2% of the recording length and a poisoning ratio of 0.05, backdoor accuracy reached 97.67% without significantly affecting the benign accuracy. In the normal setting, the accuracy is 85.08%, while the benign accuracy drops only 2% (83.05%). Furthermore, backdoor performance improves with increased poisoning ratio and trigger length. When the trigger length ratio is 2% and the poisoning ratio is 0.01, backdoor accuracy is 0%. However, when the poisoning ratio is 0.1 and the length ratio is 5%, backdoor accuracy reaches nearly 100%.
MIMIC-III · ICU mortality predictionLogistic Regression with backdoor attackbackdoor accuracy94.05%model=logistic-regression · attack=backdoor · trials=5 · poisoning-ratio=0.01
Source quote
L402: We randomly generated a backdoor trigger matrix with a mean of 0.1, applying it only to the selected features. We repeated each trial 5 times with different poisoning ratios and reported the average benign accuracy and backdoor accuracy. Figure~\ref{fig:backdoor_result_mortality} shows that backdoor accuracy increases as the poisoning ratio increases. Notably, our attacks have minimal impact on benign accuracy and maintain high backdoor accuracy (94.05%) even at low poisoning ratios (0.01) for Logistic Regression.
Reported baseline / comparator measurements (2)
BenchmarkMethodMetricScoreProtocol / Evidence
2017 PhysioNet/CinC Challenge ECG datasetUnpoisoned 13-layer ECG diagnostic CNN baselineaccuracy85.08%model=13-layer-CNN · classes=4 · setting=unpoisoned
Source quote
L361: Figure~\ref{fig:backdoor_result} demonstrates that ECG diagnostic CNN is highly vulnerable to our proposed backdoor attacks. With a trigger length that is only 2% of the recording length and a poisoning ratio of 0.05, backdoor accuracy reached 97.67% without significantly affecting the benign accuracy. In the normal setting, the accuracy is 85.08%, while the benign accuracy drops only 2% (83.05%). Furthermore, backdoor performance improves with increased poisoning ratio and trigger length. When the trigger length ratio is 2% and the poisoning ratio is 0.01, backdoor accuracy is 0%. However, when the poisoning ratio is 0.1 and the length ratio is 5%, backdoor accuracy reaches nearly 100%.
2017 PhysioNet/CinC ECG-based CNN modelsShokri et al. membership inference attack baselinebalanced accuracy0.535attack=Shokri-et-al · control-ratio=0.01
Source quote
L576: 0.01 │ 0.2% │ 0.535 │ 0.539
BibTeX
@misc{chang2024sok,
  author = {Yuanhaur Chang and Han Liu and Evin Jaff and Chenyang Lu and Ning Zhang},
  title = {{SoK: Security and Privacy Risks of Medical AI}},
  year = {2024},
  eprint = {2409.07415},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2409.07415},
}
Figure