NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Soft x-ray spectrometer (SXS): the high-resolution cryogenic spectrometer onboard ASTRO-H

Kazuhisa Mitsuda, Richard L. Kelley, Hiroki Akamatsu, Thomas G. Bialas, K. R. Boyce, G. V. Brown, Edgar R. Canavan, Meng P. Chiao, E. Costantini, Jan‐Willem den Herder, Cor de Vries, Michael DiPirro, Megan E. Eckart, Yuichiro Ezoe, Ryuichi Fujimoto, Daniel Haas, Akio Hoshino, Kumi Ishikawa, Yoshitaka Ishisaki, Naoko Iyomoto, Caroline A. Kilbourne, Mark O. Kimball, Shunji Kitamoto, Saori Konami, Maurice A. Leutenegger, D. McCammon, Joseph J. Miko, Ikuyuki Mitsuishi, Hiroshi Murakami, Masahide Murakami, Hirofumi Noda, Mina Ogawa, Takaya Ohashi, Atsushi Okamoto, Naomi Ota, S. Paltani, F. S. Porter, Kosuke Sato, Yoichi Sato, Makoto Sawada, Hiromi Seta, Keisuke Shinozaki, Peter Shirron, Gary A. Sneiderman, Hiroyuki Sugita, Andrew E. Szymkowiak, Yoh Takei, Toru Tamagawa, M. Tashiro, Y. Terada, Masahiro Tsujimoto, S. Yamada, Noriko Y. YamasakiProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE 2014

Abstract

We present the development status of the Soft X-ray Spectrometer (SXS) onboard the ASTRO-H mission. The SXS provides the capability of high energy-resolution X-ray spectroscopy of a FWHM energy resolution of < 7eV in the energy range of 0.3 – 10 keV. It utilizes an X-ray micorcalorimeter array operated at 50 mK. The SXS microcalorimeter subsystem is being developed in an EM-FM approach. The EM SXS cryostat was developed and fully tested and, although the design was generally confirmed, several anomalies and problems were found. Among them is the interference of the detector with the micro-vibrations from the mechanical coolers, which is the most difficult one to solve. We have pursued three different countermeasures and two of them seem to be effective. So far we have obtained energy resolutions satisfying the requirement with the FM cryostat.
BibTeX
@inproceedings{mitsuda2014soft,
  author = {Kazuhisa Mitsuda and Richard L. Kelley and Hiroki Akamatsu and Thomas G. Bialas and K. R. Boyce and G. V. Brown and Edgar R. Canavan and Meng P. Chiao and E. Costantini and Jan‐Willem den Herder and Cor de Vries and Michael DiPirro and Megan E. Eckart and Yuichiro Ezoe and Ryuichi Fujimoto and Daniel Haas and Akio Hoshino and Kumi Ishikawa and Yoshitaka Ishisaki and Naoko Iyomoto and Caroline A. Kilbourne and Mark O. Kimball and Shunji Kitamoto and Saori Konami and Maurice A. Leutenegger and D. McCammon and Joseph J. Miko and Ikuyuki Mitsuishi and Hiroshi Murakami and Masahide Murakami and Hirofumi Noda and Mina Ogawa and Takaya Ohashi and Atsushi Okamoto and Naomi Ota and S. Paltani and F. S. Porter and Kosuke Sato and Yoichi Sato and Makoto Sawada and Hiromi Seta and Keisuke Shinozaki and Peter Shirron and Gary A. Sneiderman and Hiroyuki Sugita and Andrew E. Szymkowiak and Yoh Takei and Toru Tamagawa and M. Tashiro and Y. Terada and Masahiro Tsujimoto and S. Yamada and Noriko Y. Yamasaki},
  title = {{Soft x-ray spectrometer (SXS): the high-resolution cryogenic spectrometer onboard ASTRO-H}},
  booktitle = {Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE},
  year = {2014},
  doi = {10.1117/12.2057199},
}

Loading related content...

Figure