SN-ABSTOPK: AN UNROLLED SPATIAL-NORMATIVE SPARSE AUTOENCODER FOR MEDICAL FOUNDATION MODELS
Its authors withdrew this paper, so there is no full text to read or summarize.
Abstract
Sparse autoencoders (SAEs) decompose foundation model representations into monosemantic latents. However, applying independent per-token sparsity across image grids ignores spatial correlations, which causes feature fragmentation in medical imaging. We introduce Spatial-Normative AbsTopK (SN-AbsTopK), an unrolled sparse autoencoder that integrates spatial group support containment and normative reference centering into signed-magnitude dictionary learning. Rather than evaluating tokens independently, SN-AbsTopK operates via a two-stage se- lection mechanism across spatial token groups. This structure enables effective processing across continuous regions, such as contiguous histology tiles or vol- umetric MRI slice stacks. In the first stage, the model aggregates pre-activation column energies across all group tokens to rank dictionary atoms and establish a shared group candidate support. In the second stage, each individual token se- lects its active signed features strictly from within this shared group candidate pool. This guarantees that all token-level active features remain strict subsets of the group candidate set. To isolate disease-specific variations, an exponential moving average reference buffer first centers the input embeddings. This pro- cess forces the sparse latent codes to represent residual departures from base- line reference states. Evaluated across histopathology (BCSS with frozen UNI) and radiology (CheXpert and Duke Breast MRI with frozen BiomedCLIP), SN- AbsTopK substantially enhances structural continuity, increasing spatial autocor- relation by 2.9× on BCSS (Moran’s 0.244 vs. 0.084) and 3D adjacent-slice sup- port persistence by 60.7% on Duke MRI (Jaccard 0.614 vs. 0.382). Although strict candidate bounds increase reconstruction error and cause feature lock-out ( 80% dead atoms), raw reconstruction error proves decoupled from clinical de- codability. Consequently, SN-AbsTopK yields superior downstream linear probe performance (+0.085 macro-AUROC on CheXpert; +0.033 on Duke MRI).
BibTeX
@misc{abdullah2027sn,
author = {Abdullah and Haider Ali and Tao Huang and Ickjai Lee and Euijoon Ahn},
title = {{SN-ABSTOPK: AN UNROLLED SPATIAL-NORMATIVE SPARSE AUTOENCODER FOR MEDICAL FOUNDATION MODELS}},
year = {2027},
url = {https://openreview.net/forum?id=Zi02GW4phv},
howpublished = {OpenReview},
note = {Submitted to ICLR 2027},
}Ask Althea to put this paper to the test.
Loading related content...