Smooth tensor decomposition with application to ambulatory blood pressure monitoring data

Lingmei Qian, R. Nisha Aurora, Naresh M. Punjabi, Irina GaynanovaarXiv 2025 · DOI

Abstract

Ambulatory blood pressure monitoring (ABPM) enables continuous measurement of blood pressure and heart rate over 24 hours and is increasingly used in clinical studies. However, ABPM data are often reduced to summary statistics, such as means or medians, which obscure temporal features like nocturnal dipping and individual chronotypes. Functional data analysis methods better capture these temporal dynamics but typically treat each ABPM measurement separately, limiting their ability to leverage correlations among matched measurements. In this work, we observe that aligning ABPM data along measurement type, time, and patient ID lends itself to a tensor representation—a multidimensional array. Although tensor learning has shown great potential in other fields, it has not been applied to ABPM data. Existing tensor learning approaches often lack temporal smoothing constraints, assume no missing data, and can be computationally demanding. To address these limitations, we propose a novel smooth tensor decomposition method that incorporates a temporal smoothing penalty and accommodates missing data. We also develop an automatic procedure for selecting the optimal smoothing parameter and tensor ranks. Simulation studies demonstrate that our method reliably reconstructs smooth temporal trends from noisy, incomplete data. Application to ABPM data from patients with concurrent obstructive sleep apnea and type 2 diabetes uncovers clinically relevant associations between patient characteristics and ABPM measurements, which are missed by summary-based approaches.

Introduction

Ambulatory blood pressure monitoring (ABPM) devices track a patient's blood pressure and heart rate continuously over 24 hours, providing a rich, dynamic picture of cardiovascular health. This high-resolution data captures critical phenomena like "nocturnal dipping"—the natural drop in blood pressure during sleep—which is a key indicator of cardiovascular risk.

Despite the richness of this data, researchers typically analyze it by collapsing 24 hours of readings into simple daytime and nighttime averages. This approach discards valuable temporal dynamics and ignores individual variations in sleep schedules (chronotypes). While Functional Data Analysis (FDA) can model continuous time curves, it often treats measurements like Systolic Blood Pressure (SBP), Diastolic Blood Pressure (DBP), and Heart Rate (HR) in isolation, failing to leverage the inherent correlations between them.

Methodology: SmoothHOOI

To address these limitations, the authors propose SmoothHOOI (Smooth Higher-Order Orthogonal Iteration). This method recognizes that ABPM data naturally forms a 3D tensor $\mathcal{M}$ indexed by Hour, Patient, and Measurement Type. By treating these dimensions jointly, the model can "borrow strength" across different cardiovascular metrics.

Tensor representation and decomposition of ABPM data into temporal, patient, and measurement components.

As illustrated in the figure above, the tensor $\mathcal{M}$ is decomposed into factor matrices representing temporal patterns ($L$), patient-specific loadings ($I$), and measurement types ($R$), linked by a core tensor $\mathcal{G}$.

Key Innovations

  • The Smoothing Paradox: Standard tensor decomposition doesn't ensure that extracted time curves are smooth. However, the authors discovered that applying smoothness constraints directly to orthogonal tensor components causes mathematical instability, creating exaggerated sinusoidal waves. SmoothHOOI solves this by applying a temporal smoothing penalty (using a second-order difference matrix) to the reconstructed data fit rather than the individual components.
  • Handling Missing Data: ABPM data is frequently incomplete due to device failure or patient non-compliance. SmoothHOOI embeds an iterative imputation loop into the optimization algorithm and uses a tailored $k$-fold cross-validation procedure to select optimal smoothing parameters and tensor ranks even with missing entries.
  • Automatic Chronotype Extraction: The method naturally isolates temporal components that represent shifts in individual sleep timing, allowing for analysis without manual alignment of patient sleep schedules.

Experimental Results

Simulation Studies

The authors benchmarked SmoothHOOI against standard Functional Principal Component Analysis (FPCA) using synthetic datasets with varying noise levels and missing data patterns. SmoothHOOI consistently achieved lower reconstruction errors and more accurately recovered true temporal trends, particularly in high-noise environments or when up to 50% of the data was missing.

Clinical Application: The HYPNOS Trial

The method was applied to baseline data from 207 adults with type 2 diabetes and moderate-to-severe obstructive sleep apnea (OSA). Traditional analysis—averaging daytime and nighttime BP—failed to find a statistically significant link between OSA severity (measured by the oxygen desaturation index, ODI4) and blood pressure after correcting for multiple tests.

In contrast, SmoothHOOI successfully isolated an overall BP/HR level component and identified a clinically meaningful, statistically significant positive association between OSA severity and elevated cardiovascular metrics. A parsimonious model using just three temporal components and two measurement components explained 59% of the total variation in this complex dataset.

Conclusion

SmoothHOOI provides a powerful framework for analyzing multi-dimensional clinical monitoring data. By incorporating temporal smoothing and joint measurement modeling, it uncovers physiological signals that are invisible to traditional summary-based methods. While the current computational cost of cross-validation is a limitation for high-frequency wearable data, future work on Generalized Cross-Validation (GCV) and extensions to higher-order tensors promises to expand the utility of this approach in personalized medicine.

Summary updated

Abstract

Ambulatory blood pressure monitoring (ABPM) enables continuous measurement of blood pressure and heart rate over 24 hours and is increasingly used in clinical studies. However, ABPM data are often reduced to summary statistics, such as means or medians, which obscure temporal features like nocturnal dipping and individual chronotypes. Functional data analysis methods better capture these temporal dynamics but typically treat each ABPM measurement separately, limiting their ability to leverage correlations among matched measurements. In this work, we observe that aligning ABPM data along measurement type, time, and patient ID lends itself to a tensor representation--a multidimensional array. Although tensor learning has shown great potential in other fields, it has not been applied to ABPM data. Existing tensor learning approaches often lack temporal smoothing constraints, assume no missing data, and can be computationally demanding. To address these limitations, we propose a novel smooth tensor decomposition method that incorporates a temporal smoothing penalty and accommodates missing data. We also develop an automatic procedure for selecting the optimal smoothing parameter and tensor ranks. Simulation studies demonstrate that our method reliably reconstructs smooth temporal trends from noisy, incomplete data. Application to ABPM data from patients with concurrent obstructive sleep apnea and type 2 diabetes uncovers clinically relevant associations between patient characteristics and ABPM measurements, which are missed by summary-based approaches.

Empirical ResultsBrowse all benchmarks →

BenchmarkMethodMetricScoreProtocol / Evidence
HYPNOS ABPM (mean daytime/nighttime summaries)Multiple linear regression (traditional summary-statistic approach)log(ODI4) coefficient; outcome: mean daytime SBP2.900Regression · approach=traditional-summary-statistic · sample_size=191
Source quote
L505: log(ODI4) │ 2.900 │ 2.705 │ 2.599 (**) │ 2.554 (*) │ 2.101 │ 1.604
HYPNOS ABPM (mean daytime/nighttime summaries)Multiple linear regression (traditional summary-statistic approach)log(ODI4) coefficient; outcome: mean nighttime SBP2.705Regression · approach=traditional-summary-statistic · sample_size=191
Source quote
L505: log(ODI4) │ 2.900 │ 2.705 │ 2.599 (**) │ 2.554 (*) │ 2.101 │ 1.604
HYPNOS ABPM (mean daytime/nighttime summaries)Multiple linear regression (traditional summary-statistic approach)log(ODI4) coefficient; outcome: mean daytime DBP2.599Regression · approach=traditional-summary-statistic · sample_size=191
Source quote
L505: log(ODI4) │ 2.900 │ 2.705 │ 2.599 (**) │ 2.554 (*) │ 2.101 │ 1.604
HYPNOS ABPM (mean daytime/nighttime summaries)Multiple linear regression (traditional summary-statistic approach)log(ODI4) coefficient; outcome: mean nighttime DBP2.554Regression · approach=traditional-summary-statistic · sample_size=191
Source quote
L505: log(ODI4) │ 2.900 │ 2.705 │ 2.599 (**) │ 2.554 (*) │ 2.101 │ 1.604
HYPNOS ABPM (mean daytime/nighttime summaries)Multiple linear regression (traditional summary-statistic approach)log(ODI4) coefficient; outcome: mean daytime HR2.101Regression · approach=traditional-summary-statistic · sample_size=191
Source quote
L505: log(ODI4) │ 2.900 │ 2.705 │ 2.599 (**) │ 2.554 (*) │ 2.101 │ 1.604
HYPNOS ABPM (mean daytime/nighttime summaries)Multiple linear regression (traditional summary-statistic approach)log(ODI4) coefficient; outcome: mean nighttime HR1.604Regression · approach=traditional-summary-statistic · sample_size=191
Source quote
L505: log(ODI4) │ 2.900 │ 2.705 │ 2.599 (**) │ 2.554 (*) │ 2.101 │ 1.604
BibTeX
@misc{qian2025smooth,
  author = {Lingmei Qian and R. Nisha Aurora and Naresh M. Punjabi and Irina Gaynanova},
  title = {{Smooth tensor decomposition with application to ambulatory blood pressure monitoring data}},
  year = {2025},
  eprint = {2507.11723},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2507.11723},
  howpublished = {arXiv},
}
Figure