Size Effect of Interlacer

Yoshiyuki Iemoto, Shigeomi Chono, Hong Qin, Weichun LouJournal of Textile Engineering 2000 · DOI

TL;DR

This study reveals that in textile interlacers, increasing supply air pressure doesn't always lead to higher internal pressure due to the formation of alternating expansion and compression waves in supersonic jets. By analyzing various geometric ratios, the researchers identified that specific configurations (like a diameter ratio of 1.6 and medium duct lengths) create the high spatial pressure variations necessary for optimal yarn tangling.

What Problem Does This Paper Address?

In textile manufacturing, "interlacing" is a critical process where a high-speed air jet hits a moving yarn to tangle its filaments, providing structural integrity without twisting. Despite its importance, the "size effect"—how the physical dimensions of the interlacer device influence the airflow—has remained poorly understood.

Small changes in the diameter of the yarn duct or the air nozzle can lead to wildly different results in yarn quality. Previous studies often contradicted each other because the small scale of these devices makes accurate measurement difficult. This paper seeks to provide a definitive map of how geometry and supply pressure interact to create the pressure distributions that drive the interlacing process.

Methods

To overcome the difficulty of measuring pressure in tiny, millimetric devices, the authors used enlarged models made of acrylic resin. This allowed for higher spatial resolution when drilling pressure holes and placing sensors.

The team focused on two primary non-dimensional parameters:

  1. Diameter Ratio ($R_d$): The ratio of the yarn duct diameter ($d$) to the air jet nozzle diameter ($d_n$).
  2. Non-dimensional Duct Length ($L_d$): The yarn duct length ($l_d$) divided by its diameter ($d$).

Beyond static pressure measurements, the researchers employed Schlieren photography—a technique that visualizes changes in air density. This allowed them to "see" the shock waves and expansion zones within the air jet, providing a physical explanation for the numerical data.

Datasets

As an experimental fluid dynamics paper, it does not use external digital datasets. Instead, it generates original experimental data across:

  • 41 different interlacer geometries (varying $R_d$ from 1.0 to 3.2 and $L_d$ from 1.0 to 15.0).
  • Supply air pressures ranging from 0.1 to 0.6 MPa.

Key Insights and Ideas

  • The Supersonic Surprise: The air jet chokes and becomes supersonic at supply pressures above 0.09 MPa. This means the flow isn't just a simple stream; it's a complex structure of "diamonds"—alternating zones of high-pressure compression and low-pressure expansion.
  • Non-Monotonic Pressure: Counter-intuitively, for certain geometries ($R_d$ between 1.8 and 2.6), increasing the supply pressure actually decreases the pressure on the duct wall at specific points. This happens because the "vibrating" wave pattern of the jet shifts as pressure rises, moving a low-pressure expansion zone directly over the measurement point.
  • The "Suction" Effect: In longer ducts ($L_d \ge 3.7$), the pressure doesn't just drop to zero; it actually becomes negative (gauge pressure) near the jet exit before returning to atmospheric levels. This creates a complex "push-pull" dynamic on the yarn filaments.
  • The Sweet Spot for Processability: The authors suggest that high "processability" (better tangling) occurs when there is a large spatial variation in pressure. This is most prominent when $R_d = 1.6$ and $L_d$ is between 3.7 and 7.0.

Key Results

  • Optimal Ratios: For $R_d = 1.6$, the pressure distribution is highly sensitive to supply pressure, creating the "steep" gradients needed for vigorous filament movement.
  • Duct Length Impact: In short ducts ($L_d \le 3.0$), pressure decreases monotonically from the center to the edges. In long ducts ($L_d \ge 7.0$), the air reaches atmospheric pressure well before exiting the duct, which can increase yarn tension unnecessarily and hinder tangling.
  • Wave Periodicity: Schlieren photos confirmed that as supply pressure increases, the period (length) of the expansion/compression waves grows, explaining why wall pressure fluctuates non-linearly with supply pressure.

Limitations and Future Work

The most significant limitation acknowledged is that these measurements were taken without a yarn in the duct. While this is necessary to establish a baseline of the fluid dynamics, a moving yarn would introduce turbulence and partially block the airflow, likely altering the pressure distribution.

The authors suggest that future research should integrate these airflow findings with actual yarn motion studies to fully close the loop on interlacer design. Additionally, while the enlarged models provide great data, the "scaling effect" (ensuring the physics remains identical at the tiny scale of real production) relies on Reynolds and Mach number similarity, which may have slight deviations in practice.

Summary updated

Abstract

In order to clarify the size effect of an interlacer, we measured air pressure distributions on the yam duct wall of interlacers with various sizes of both yarn duct and air jet nozzle for a wide range of the supplied air pressure in a rectification tank. The pressure in the yarn duct does not always increase with the supplied air pressure p and depends upon the diameter ratio Rd(=d/dn), where d and dn are the diameters of the yarn duct and the air jet nozzle, respectively. This is because expansion and compression waves occur alternately in the jet issuing from an air jet nozzle. In interlacers with Rd=2.0, at p=0.4 MPa the pressure ps on the yarn duct wall of interlacers with Ld_??_3.0 takes a maximum at Z=0 and monotonously decreases to the atmospheric pressure with |Z|. Here, Ld is the non-dimensional yarn duct length defined by ld/d(where ld is the yarn duct length), and Z is the non-dimensional axial coordinate scaled by d and measured with respect to the center of an air jet nozzle exit. The value of ps for Ld_??_3.7 takes a negative value near |Z|=1-3 and then increases to the atmospheric pressure. The value of ps for Ld_??_7.0 is equal to the atmospheric pressure in |Z|_??_3. At p=0.2MPa, ps having a maximum at Z=0 decreases monotonously with |Z| and equals the atmospheric pressure in |Z|_??_1. At p=0.4MPa, ps monotonously decreases with |Z| in the interlacers with Ld_??_3.0 and Rd=2.4 or with Ld_??_2.3 and Rd=1.6. It may be supposed that interlacers with Rd=1.6 and Ld=3.7-7.0 have high processability because the pressure distribution in these interlacers expresses a large variation in space.
BibTeX
@article{iemoto2000size,
  author = {Yoshiyuki Iemoto and Shigeomi Chono and Hong Qin and Weichun Lou},
  title = {{Size Effect of Interlacer}},
  journal = {Journal of Textile Engineering},
  year = {2000},
  doi = {10.4188/jte.46.11},
}
Figure