Simultaneous Reconstruction of Gas Concentration and Temperature Using Acoustic Tomography

Shuangling Liu, Ming Zhu, Meng Deng, Zesheng Hu, Zhuo Cheng, Xingshun He2024

TL;DR

This paper introduces a novel acoustic tomography (AT) method that can simultaneously reconstruct gas concentration and temperature fields using only the speed of sound. By leveraging the dispersion of sound speed with frequency, this approach offers a cost-effective and non-contact solution for monitoring critical industrial environments.

What Problem Does This Paper Address?

Accurate monitoring of gas concentration and temperature is crucial for safety and efficiency in industrial processes like boiler furnaces and engine nozzles. While optical methods like TDLAS offer high precision, they are expensive and complex. Acoustic tomography (AT) presents a more practical alternative due to its low cost and ease of installation. However, existing AT research primarily focuses on reconstructing temperature fields, with limited work on simultaneous reconstruction of both temperature and concentration. Existing methods often require multiple measurements (e.g., sound speed and absorption), and sound absorption measurements can be prone to error. This paper aims to fill this gap by developing a method that reconstructs both gas concentration and temperature fields using solely the speed of sound, exploiting its frequency-dependent behavior.

Methods

The core of this research lies in utilizing the phenomenon of acoustic relaxation in excitable gases. The speed of sound in such gases is not constant but varies with frequency due to the delay in internal energy relaxation processes. This frequency dependence, or dispersion, is what the authors exploit.

  1. Acoustic Relaxation Model: The paper starts by establishing the theoretical basis, relating the speed of sound ($c$) to gas properties like molar mass ($M$), temperature ($T$), and a frequency-dependent heat capacity ratio ($\gamma(\omega)$). The $\gamma(\omega)$ term is further broken down to include the effective isochoric specific heat ($C_{eff}(\omega)$), which captures the molecular relaxation effects.
  2. Projection Intersection Method: For binary gas mixtures, the method involves measuring the speed of sound at two different frequencies. The relationship between speed of sound, concentration, and temperature is modeled as a 3D surface. By taking horizontal slices at the measured speeds of sound for each frequency, two curves are obtained. The intersection of these curves on a 2D plane (concentration vs. temperature) uniquely identifies the gas concentration and temperature. This is termed the "projection intersection method."
  3. Extension to Ternary Mixtures: For ternary mixtures, the approach is extended by using three frequencies. This creates a more complex, four-dimensional relationship (speed of sound vs. two concentrations and temperature). The graphical method is adapted by projecting the intersection curves from three frequency measurements onto a common plane, allowing for the determination of two gas concentrations and the temperature.
  4. Reconstruction Algorithm: The overall AT reconstruction process involves:
  5. Dividing the area of interest into discrete grids.
  6. Arranging acoustic sensors to create multiple propagation paths.
  7. Measuring the time of flight (TOF) for each path.
  8. Using the least squares method (LSM) to invert the TOF data and obtain the speed of sound in each grid cell for each frequency.
  9. Employing Gaussian Process Regression (GPR) for interpolation to refine the speed of sound field.
  10. Applying the projection intersection method to the refined speed of sound data to determine concentration and temperature fields.

Datasets

The paper does not describe the use of pre-existing datasets for training. Instead, it relies on:

  • Numerical Simulations: The authors create synthetic datasets by defining various known concentration and temperature distributions (single-peak symmetric, double-peak symmetric, double-peak skewed) for binary (CO2-N2) and ternary (CO2-CH4-N2) gas mixtures. These simulated scenarios are used to test the reconstruction algorithm.
  • Experimental Data: The authors conduct experiments using a custom-built AT system. They introduce controlled amounts of CO2 and air (or CO2, CH4, and N2) and use electric heaters to create known temperature gradients. The system measures TOF data, which is then processed to reconstruct the concentration and temperature fields. These experimental results are compared against measurements from portable gas detectors and thermocouple thermometers.

Key Insights and Ideas

  • Sound Speed Dispersion as a Dual Probe: The most significant insight is that the frequency-dependent speed of sound (acoustic dispersion) can simultaneously encode information about both gas concentration and temperature. This bypasses the need for separate measurements or multiple sensor types.
  • Graphical Approach for Inversion: The "projection intersection method" offers an intuitive and effective way to solve the inverse problem for binary and ternary mixtures by visualizing the intersection of multiple measurement-derived curves.
  • Feasibility of Simultaneous Reconstruction: The study demonstrates that it is indeed possible to decouple the effects of concentration and temperature on sound speed, enabling simultaneous reconstruction.
  • Cost-Effectiveness of AT: The paper reinforces the advantage of AT as a low-cost, non-contact sensing technology compared to optical methods, making it suitable for large-scale industrial applications.

Key Results

The paper presents results from both numerical simulations and experimental studies.

Numerical Simulations: * Binary Gas Mixtures (CO2-N2): Reconstruction errors (Erms) for concentration were generally below 4% for symmetric distributions and around 5% for skewed distributions. Temperature reconstruction errors (Erms) were even lower, around 0.5-0.8%. * Ternary Gas Mixtures (CO2-CH4-N2): For single-peak symmetric distributions, Erms for CO2 was around 10.5%, CH4 around 5.8%, and temperature around 1.7%. For double-peak symmetric distributions, Erms for CO2 was around 5.2%, CH4 around 8.9%, and temperature around 1.3%.

Experimental Results: * Experiment 1 (CO2 source): Reconstructed CO2 concentration peak was around 8%, close to the measured 6.3%. Temperature errors at measurement points were within 7 K. * Experiment 2 (CO2 source + heater): Reconstructed temperature errors were within 5% at most points, with the error at the heat source being larger. Concentration measurements were close to reconstruction results. * Experiment 3 (CO2 source + heater, different placement): Peak concentration error was 1.1%. Temperature errors at the heater position were around 5 K, and at edge positions within 8 K.

Overall, the results show that the proposed method can effectively reconstruct concentration and temperature fields under various conditions, with experimental errors generally within acceptable ranges for many industrial applications.

Limitations and Future Work

Limitations: * Noise Interference: The TOF measurements are susceptible to environmental noise, which can impact accuracy. * Limited Number of Sensors: The current setup uses a limited number of sensors, especially when measuring multiple frequencies simultaneously, which restricts the resolution and fine imaging capabilities. * Instability of Concentration: In open environments, maintaining stable airflow and thus constant gas concentration is challenging, leading to variations that can affect dynamic imaging. * Initial Grid Division: In simulations, insufficient refinement of the initial grid for speed of sound inversion can lead to errors, particularly at peak points.

Future Work: * Dynamic Detection: Focus on dynamic detection of gas state fields, implying real-time monitoring. * Extreme Environments: Extend the application to detection in extreme environments. * Improving Accuracy: Increase the number and distribution of sensors to enhance resolution and accuracy. * Advanced Algorithms: Develop dynamic gas imaging algorithms to mitigate the impact of concentration fluctuations and improve stability.

Summary updated

BibTeX
@misc{liu2024simultaneous,
  author = {Shuangling Liu and Ming Zhu and Meng Deng and Zesheng Hu and Zhuo Cheng and Xingshun He},
  title = {{Simultaneous Reconstruction of Gas Concentration and Temperature Using Acoustic Tomography}},
  year = {2024},
  doi = {10.3390/s24103128},
}

Loading related content...